Twenty-year follow-up of the Hancock modified orifice porcine aortic valve

被引:66
|
作者
Cohn, LH [1 ]
Collins, JJ [1 ]
Rizzo, RJ [1 ]
Adams, DH [1 ]
Couper, GS [1 ]
Aranki, SF [1 ]
机构
[1] Harvard Univ, Div Cardiac Surg, Dept Surg, Brigham & Womens Hosp,Med Sch, Boston, MA 02115 USA
来源
ANNALS OF THORACIC SURGERY | 1998年 / 66卷 / 06期
关键词
D O I
10.1016/S0003-4975(98)01105-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The entire experience with the Hancock modified orifice porcine bioprosthetic aortic valve from 1976 to 1996 at the Brigham and Women's Hospital has been reviewed. Eight hundred forty-three patients received this valve with a total follow-up of 61,114 months, and a mean follow-up of approximately 72.5 months. There were 490 men and 353 women, and the predominate lesion was aortic stenosis (636 of 843); 365 (43%) patients required a concomitant coronary artery bypass graft operation. Methods. patients were followed prospectively in the Brigham Cardiac Valve Data Registry, and the data were analyzed by the SAS statistical package, using actuarial survival curves and incidence per patient-year of morbidity and mortality. Results. The overall operative mortality was 45 of 843 (5.3%) with 23 of 478 (4.8%) for isolated aortic valve replacement and 22 of 365 (6.0%) for aortic valve plus coronary artery bypass graft operation. The major morbidity of this valve was structural valve dysfunction, which was significantly related to the age of the patient in whom the valve was placed. Actuarial probability of freedom from structural valve degeneration at 5, 10, and 15 years overall was 99% +/- 1%, 79% +/- 3% and 57% +/- 4%, at 15 years, respectively. In patients younger than 50 years, freedom from structural valve dysfunction was 16% +/- 8%, whereas in the age group older than 70 years it was 87% +/- 5% (p = 0.0005). Thromboembolism at 10 and 15 years was 81% +/- 3% overall, 84% +/- 2% in patients in normal sinus rhythm, and 57% +/- 13% in patients with chronic atrial fibrillation. Conclusions. The Hancock modified orifice aortic valve, despite its more complicated fabrication, has been a reliable porcine bioprosthetic valve and can be used reliably in patients older than 70 years because of its low structural valve degeneration rate, and protection from stroke and anticoagulant hemorrhage in those patients in sinus rhythm. (C) 1998 by The Society of Thoracic Surgeons.
引用
收藏
页码:S30 / S34
页数:5
相关论文
共 50 条
  • [31] Twenty-year follow-up after percutaneous transluminal coronary angioplasty
    Abizaid, AS
    Sousa, A
    Centemero, M
    Abizaid, A
    Chaves, A
    Tanajura, LF
    Seixas, AC
    Sousa, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 11A - 11A
  • [32] TWENTY-YEAR FOLLOW-UP OF NEWBORN SCREENING FOR PATIENTS WITH MUSCULAR DYSTROPHY
    Chung, Jeffrey
    Smith, Andrea L.
    Hughes, Sarah C.
    Niizawa, Gabriela
    Abdel-Hamid, Hoda Z.
    Naylor, Edwin W.
    Hughes, Timothy
    Clemens, Paula R.
    MUSCLE & NERVE, 2016, 53 (04) : 570 - 578
  • [33] College cheating: A twenty-year follow-up and the addition of an honor code
    Vandehey, Michael A.
    Diekhoff, George M.
    LaBeff, Emily E.
    JOURNAL OF COLLEGE STUDENT DEVELOPMENT, 2007, 48 (04) : 468 - 480
  • [34] A Twenty-Year Follow-up Study of Trabeculectomy: Risk Factors and Outcomes
    Landers, John
    Martin, Keith
    Sarkies, Nicholas
    Bourne, Rupert
    Watson, Peter
    OPHTHALMOLOGY, 2012, 119 (04) : 694 - 702
  • [35] Effects of father participation in child rearing: Twenty-year follow-up
    Williams, E
    Radin, N
    AMERICAN JOURNAL OF ORTHOPSYCHIATRY, 1999, 69 (03) : 328 - 336
  • [36] Twenty-year experience with aortic valve replacement in children
    Lupinetti, FM
    Duncan, BW
    Dyamenahalli, U
    Rosenthal, GL
    CIRCULATION, 2002, 106 (19) : 395 - 395
  • [37] Twenty-year results of the Hancock II bioprosthesis
    Borger, MA
    Ivanov, J
    Armstrong, S
    Christie-Hrybinsky, D
    Feindel, CM
    David, TE
    JOURNAL OF HEART VALVE DISEASE, 2006, 15 (01): : 49 - 55
  • [38] Aortic Valve Repair: 49 Year Follow-up
    Haydock, Matthew D.
    Haydock, David A.
    HEART LUNG AND CIRCULATION, 2013, 22 (09): : 767 - 768
  • [39] THE HANCOCK MODIFIED-ORIFICE PORCINE BIOPROSTHETIC VALVE - 1976-1988
    COHN, LH
    DISESA, VJ
    COLLINS, JJ
    ANNALS OF THORACIC SURGERY, 1989, 48 (03): : S81 - S82
  • [40] Twenty-year follow-up of blood pressure and neurohormones in hypertensive and normotensive men
    Gudmundsdottir, H.
    Strand, A.
    Hoieggen, A.
    Kjeldsen, S. E.
    Os, I.
    JOURNAL OF HYPERTENSION, 2007, 25 : S38 - S38