Pulsed electrospray for mass spectrometry

被引:24
|
作者
Lu, Y
Zhou, F
Shui, WQ
Bian, LP
Yang, PY [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Organ Chem, Shanghai 200032, Peoples R China
关键词
D O I
10.1021/ac0103118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pulsed electrospray has been developed and been reported for the first time. This new technique is based on the principle of pulsed ion sources, combined with the conventional electrospray. The pulsed ion spray was realized by a homemade pulsed RV circuit and was monitored by a digital microscope and an oscilloscope. Results show that the pulsed ESI device can be operated under proper conditions for a clear on-and-off spray process and that the device was kept in good electric contact for electrospray when pulsed HV was on. A pulsed ion current and pulsed mass spectra can be achieved with this pulsed ESI device. Furthermore, it has been noted that, under the same conditions (i.e., shape and size of sprayer tip, distance from sprayer tip to sampling nozzle, and other parameters for mass spectrometer), stable electrospray could be obtained for lower flow rates with a pulsed spray device. This experimental fact indicates the possible reduction in the total sample consumed could be realized by exploiting this novel design.
引用
收藏
页码:4748 / 4753
页数:6
相关论文
共 50 条
  • [41] MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL
    BLADES, AT
    IKONOMOU, MG
    KEBARLE, P
    ANALYTICAL CHEMISTRY, 1991, 63 (19) : 2109 - 2114
  • [42] Analysis of metal species by using electrospray ionization mass spectrometry and capillary electrophoresis electrospray ionization mass spectrometry
    Schramel, O
    Michalke, B
    Kettrup, A
    JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 231 - 242
  • [43] An extended mass range quadrupole for electrospray mass spectrometry
    Collings, BA
    Douglas, DJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 162 (1-3): : 121 - 127
  • [44] Determination of micelle mass by electrospray ionization mass spectrometry
    Nohara, D
    Kajiura, T
    Takeda, K
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04): : 489 - 493
  • [45] Accurate mass analysis of phosphoramidites by electrospray mass spectrometry
    Kupihár, Z
    Timár, Z
    Dellinger, DJ
    Caruthers, MH
    NUCLEOSIDES NUCLEOTIDES & NUCLEIC ACIDS, 2005, 24 (5-7): : 663 - 666
  • [46] Identification of monohydroxy fatty acids by electrospray mass spectrometry and tandem mass spectrometry
    Kerwin, JL
    Torvik, JJ
    ANALYTICAL BIOCHEMISTRY, 1996, 237 (01) : 56 - 64
  • [47] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303
  • [48] Chiral recognition of amino acids by electrospray ionisation mass spectrometry/mass spectrometry
    Yao, ZP
    Wan, TSM
    Kwong, KP
    Che, CT
    CHEMICAL COMMUNICATIONS, 1999, (20) : 2119 - 2120
  • [50] Solvent gradient electrospray for laser ablation electrospray ionization mass spectrometry
    Li, Hang
    Vertes, Akos
    ANALYST, 2017, 142 (16) : 2921 - 2927