Hemodynamic study of TCPC using in vivo and in vitro 4D Flow MRI and numerical simulation

被引:27
|
作者
Roldan-Alzate, Alejandro [1 ]
Garcia-Rodriguez, Sylvana [1 ]
Anagnostopoulos, Petros V. [2 ,3 ]
Srinivasan, Shardha [3 ]
Wieben, Oliver [1 ,4 ]
Francois, Christopher J. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Pediat Cardiol, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
Total cavopulmonary connection; 4D Flow; Magnetic resonance imaging; Numerical simulation; Additive manufacturing; Congenital heart disease; TOTAL CAVOPULMONARY CONNECTION; FONTAN CONNECTION; BLOOD-FLOW; QUANTIFICATION; INTRAATRIAL; RESOLUTION;
D O I
10.1016/j.jbiomech.2015.03.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Introduction: Altered total cavopulmonary connection (TCPC) hemodynamics can cause long-term complications. Patient-specific anatomy hinders generalized solutions. 4D Flow MRI allows in vivo assessment, but not predictions under varying conditions and surgical approaches. Computational fluid dynamics (CFD) improves understanding and explores varying physiological conditions. This study investigated a combination of 4D Flow MRI and CFD to assess TCPC hemodynamics, accompanied with in vitro measurements as CFD validation. 4D Flow MRI was performed in extracardiac and atriopulmonary TCPC subjects. Data was processed for visualization and quantification of velocity and flow. Three-dimensional (3D) geometries were generated from angiography scans and used for CFD and a physical model construction through additive manufacturing. These models were connected to a perfusion system, circulating water through the vena cavae and exiting through the pulmonary arteries at two flow rates. Models underwent 4D Flow MRI and image processing. CFD simulated the in vitro system, applying two different inlet conditions from in vitro 4D Flow MRI measurements; no-slip was implemented at rigid walls. Velocity and flow were obtained and analyzed. The three approaches showed similar velocities, increasing proportionally with high inflow. Atriopulmonary TCPC presented higher vorticity compared to extracardiac at both inflow rates. Increased inflow balanced flow distribution in both TCPC cases. Atriopulmonary IVC flow participated in atrium recirculation, contributing to RPA outflow; at baseline, IVC flow preferentially traveled through the LPA. The combination of patient-specific in vitro and CFD allows hemodynamic parameter control, impossible in vivo. Physical models serve as CFD verification and fine-tuning tools. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 50 条
  • [41] Comparison of 4D Flow MRI and Particle Image Velocimetry Using an In Vitro Carotid Bifurcation Model
    Medero, Rafael
    Hoffman, Carson
    Roldan-Alzate, Alejandro
    ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (12) : 2112 - 2122
  • [42] Hemodynamic Parameters for Cardiovascular System in 4D Flow MRI: Mathematical Definition and Clinical Applications
    Itatani, Keiichi
    Sekine, Tetsuro
    Yamagishi, Masaaki
    Maeda, Yoshinobu
    Higashitani, Norika
    Miyazaki, Shohei
    Matsuda, Junya
    Takehara, Yasuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 380 - 399
  • [43] Hemodynamic Evaluation of Intracranial Aneurysm: Comparison of Computational Fluid Dynamics with 4D Flow MRI
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    NEUROSURGERY, 2020, 67 : 120 - 121
  • [44] Correction: In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Rafael Medero
    Katrina Falk
    David Rutkowski
    Kevin Johnson
    Alejandro Roldán-Alzate
    Annals of Biomedical Engineering, 2023, 51 : 457 - 457
  • [45] In-vitro validation of 4D flow MRI measurements with an experimental pulsatile flow model
    David, A.
    Le Touze, D.
    Warin-Fresse, K.
    Paul-Gilloteaux, P.
    Bonnefoy, F.
    Idier, J.
    Moussaoui, S.
    Guerin, P.
    Serfaty, J-M
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (01) : 17 - 23
  • [46] 4d Flow Mri Demonstrates Hemodynamic Normalization After Coarctation Repair in Pediatric Patients
    Berhane, Haben
    Shahid, Labib
    Rice, James
    Rigsby, Cynthia K.
    Robinson, Joshua D.
    Griffin, Lindsay
    Alzate, Alejandro Roldan
    Markl, Michael
    CIRCULATION, 2022, 146
  • [47] Spiral readouts for 4D flow MRI
    Andreas Sigfridsson
    Sven Petersson
    Carl Johan Carlhall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [48] Editorial for "Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI"
    Soulat, Gilles
    Mousseaux, Elie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (06) : 1764 - 1765
  • [49] Assessment of left ventricular hemodynamic forces in healthy subjects and patients with dilated cardiomyopathy using 4D flow MRI
    Eriksson, Jonatan
    Bolger, Ann F.
    Ebbers, Tino
    Carlhall, Carl-Johan
    PHYSIOLOGICAL REPORTS, 2016, 4 (03):
  • [50] Abdominal Applications of 4D Flow MRI
    Riedel, Christoph
    Lenz, Alexander
    Fischer, Lutz
    Li, Jun
    Piecha, Feilix
    Kluwe, Johannes
    Adam, Gerhard
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 388 - 398