Real-time measurement of cardiac vagal tone in conscious dogs

被引:59
|
作者
Little, CJL
Julu, POO
Hansen, S
Reid, SWJ
机构
[1] Univ Glasgow, Sch Vet, Dept Vet Clin Studies, Glasgow G61 1QH, Lanark, Scotland
[2] So Gen Hosp, Peripheral Nerve & Autonom Unit, Glasgow G51 4TF, Lanark, Scotland
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1999年 / 276卷 / 02期
关键词
NeuroScope; parasympathetic tone; heart rate variability; autonomic nervous system; atropine;
D O I
10.1152/ajpheart.1999.276.2.H758
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rapid changes in heart rate are caused by changes in parasympathetic tone. The NeuroScope is an electronic device designed to offer an objective real-time measure of instantaneous cardiac vagal tone by phase demodulation of a high-resolution time domain of R-R wave intervals. Data are displayed against an arbitrary but linear scale, the cardiac index of parasympathetic activity (CIPA). To validate this method, 10 conscious healthy dogs were each given six incremental doses of atropine (0.01 mg/kg) to a total dose of 0.06 mg/kg or equal volumes of saline. A dose-response curve was constructed. At the maximum dose of atropine, CIPA values fell to 1.3 +/- 0.7% (SD) of baseline, whereas R-R intervals fell to 51.5 +/- 11.5% of baseline, and standard deviation of the R-R wave interval fell to 10.6 +/- 6.5% of baseline. These findings show that the NeuroScope can provide a specific real-time index of cardiac vagal tone in dogs without need for recourse to atropine.
引用
收藏
页码:H758 / H765
页数:8
相关论文
共 50 条
  • [41] Effects of slowed respiration on cardiac vagal tone
    Sakakibara, M
    Hayano, J
    Kida, M
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 12420 - 12420
  • [42] CARDIAC VAGAL TONE IN GENERALIZED ANXIETY DISORDER
    KOLLAI, M
    KOLLAI, B
    BRITISH JOURNAL OF PSYCHIATRY, 1992, 161 : 831 - 835
  • [43] Real-time noise-aware tone mapping
    Eilertsen, Gabriel
    Mantiuk, Rafal K.
    Unger, Jonas
    ACM TRANSACTIONS ON GRAPHICS, 2015, 34 (06):
  • [44] Network conscious design of distributed real-time systems
    Park, JW
    Kim, YS
    Hong, SS
    Saksena, M
    Noh, SH
    Kwon, WH
    JOURNAL OF SYSTEMS ARCHITECTURE, 1998, 45 (02) : 131 - 156
  • [45] REAL-TIME AND SIMULTANEOUS MEASUREMENT OF TRICUSPID ORIFICE AND TRICUSPID ANULUS AREAS IN ANESTHETIZED DOGS
    TAMIYA, K
    HIGASHIDATE, M
    KIKKAWA, S
    CIRCULATION RESEARCH, 1989, 64 (03) : 427 - 436
  • [46] Measurement of left ventricular volume by real-time, three-dimensional echocardiography in dogs
    Ota, T
    Fleishman, CE
    Ohazama, CJ
    Stetten, G
    Lewis, CW
    Glower, DD
    Li, J
    Ryan, T
    Kisslo, J
    vonRamm, OT
    CIRCULATION, 1996, 94 (08) : 2211 - 2211
  • [47] A REAL-TIME INTEGRATED BACKSCATTER MEASUREMENT SYSTEM FOR QUANTITATIVE CARDIAC TISSUE CHARACTERIZATION
    THOMAS, LJ
    WICKLINE, SA
    PEREZ, JE
    SOBEL, BE
    MILLER, JG
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 27 - 32
  • [48] TOWARDS REAL-TIME DETECTION OF COGNITIVE EFFORT IN DRIVING: CONTRIBUTION OF A CARDIAC MEASUREMENT
    Pepin, G.
    Jallais, C.
    Fort, A.
    Moreau, F.
    Navarro, J.
    Gabaude, C.
    TRAVAIL HUMAIN, 2017, 80 (01): : 51 - 72
  • [49] Portable impedance cardiography system for real-time noninvasive cardiac output measurement
    Chiang, CY
    Hu, WC
    Shyu, LY
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2072 - 2073
  • [50] REAL-TIME CARDIAC MR FLUOROSCOPY
    DEBBINS, JP
    RIEDERER, SJ
    ROSSMAN, PJ
    GRIMM, RC
    FELMLEE, JP
    BREEN, JF
    RADIOLOGY, 1995, 197 : 181 - 181