Continuous-flow system for on line water monitoring using back side contact ISFET-based sensors

被引:32
|
作者
Jimenez, C
Marques, I
Bartroli, J
机构
[1] Sensors and Biosensors Group, Departament de Química, Univ. Autònoma de Barcelona, 08193-Bellaterra, Barcelona
[2] Dept. de Quim. Analítica, Universitat de Barcelona, 08028 Barcelona
关键词
D O I
10.1021/ac9603946
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multiparametric continuous-now system for on-line monitoring of water based on ISFET sensors is described. The ISFETs used have silicon nitride as gate material, and the electrical contacts are placed on the back side of the chip. This is a technological improvement that allows for a more compact ISFET packaging and greatly increases the lifetime of the sensor compared with planar type ISFETs, since the electrical parts are separated from the chemical environment. A special probe has been designed in order to encapsulate and apply these ISFETs into the now system, Further, a reference electrode based on standard Ag/AgCl technology has been constructed according to the ISFET probe design in order to integrate both sensors in the same flow-through cell. These probes can be easily replaced in the now system and are made of cheap and easily mechanized materials. Using these flow-through sensors, a continuous-now system for the determination of pH, NH4+, Ca2+, and NO3- in waters has been designed, The system configuration is based on a modular design (one setup for each parameter and a common sampling channel), which allows simple manipulation and maintenance as well as a good flexibility for different analytical requirements, A study of the system characteristics was performed by following the specifications for water monitoring, Under the conditions established for the flow system, a sampling rate of 20 h(-1) was obtained for each parameter, and long term stabilities of at least 3 weeks of daily work for ISFET sensors and 5 months for the reference electrode have been achieved, The response performances obtained show the feasibility of the BSC ISFET probe use in continuous-now monitoring.
引用
下载
收藏
页码:3801 / 3807
页数:7
相关论文
共 32 条
  • [21] Formation and purification of tailored liposomes for drug delivery using a module-based micro continuous-flow system (Vol 8, 2017)
    Dimov, Nikolay
    Kastner, Elisabeth
    Hussain, Maryam
    Perrie, Yvonne
    Szita, Nicolas
    SCIENTIFIC REPORTS, 2018, 8
  • [22] Continuous monitoring of pH level in flow aqueous system by using liquid crystal-based sensor device
    Chen, Wei-Long
    Ho, Tsung Yang
    Huang, Jhih-Wei
    Chen, Chih-Hsin
    MICROCHEMICAL JOURNAL, 2018, 139 : 339 - 346
  • [23] Automated continuous monitoring of drug dissolution process using a flow injection on-line dialysis sampling – solvent extraction separation spectrophotometric system
    Qun Fang
    Yu-Qing Sun
    Zhao-Lun Fang
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 347 - 352
  • [24] Automated continuous monitoring of drug dissolution process using a flow injection on-line dialysis sampling - solvent extraction separation spectrophotometric system
    Fang, Q
    Sun, YQ
    Fang, ZL
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (04): : 347 - 352
  • [25] Improved quantitative analysis of tenuifolin using hydrolytic continuous-flow system to build prediction models for its content based on near-infrared spectroscopy
    Kitazoe, Tatsuki
    Usui, Chisato
    Kodaira, Eiichi
    Maruyama, Takuro
    Kawano, Noriaki
    Fuchino, Hiroyuki
    Yamamoto, Kazuhiko
    Kitano, Yasushi
    Kawahara, Nobuo
    Yoshimatsu, Kayo
    Shirahata, Tatsuya
    Kobayashi, Yoshinori
    JOURNAL OF NATURAL MEDICINES, 2024, 78 (02) : 296 - 311
  • [26] Improved quantitative analysis of tenuifolin using hydrolytic continuous-flow system to build prediction models for its content based on near-infrared spectroscopy
    Tatsuki Kitazoe
    Chisato Usui
    Eiichi Kodaira
    Takuro Maruyama
    Noriaki Kawano
    Hiroyuki Fuchino
    Kazuhiko Yamamoto
    Yasushi Kitano
    Nobuo Kawahara
    Kayo Yoshimatsu
    Tatsuya Shirahata
    Yoshinori Kobayashi
    Journal of Natural Medicines, 2024, 78 : 296 - 311
  • [27] Continuous on-line monitoring of Trihalomethanes in chlorinated drinking water using an automated system based on pulse introduction membrane extraction and high speed gas chromatography/mass spectrometry
    Chang, CC
    Lu, PF
    Her, GR
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (05) : 921 - 926
  • [28] On-line monitoring of calcium in natural, borehole and boiler feed water with a flow injection system using a calcium-selective membrane electrode as a sensor
    van Staden, JF
    Stefan, RI
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 1999, 52 (01): : 24 - 26
  • [29] DETERMINATION OF ARSENIC IN A NICKEL BASED ALLOY USING A MICROWAVE-DIGESTION PROCEDURE AND A CONTINUOUS-FLOW HYDRIDGE GENERATION ATOMIC-ABSORPTION SYSTEM INCORPORATING ONLINE MATRIX REMOVAL
    RIBY, PG
    HASWELL, SJ
    GRZESKOWIAK, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) : 181 - 184
  • [30] Degradation of sertraline using a continuous-flow filtration/photocatalysis system based on carbon fiber (PWB-3) modified with WO3 under LED chip irradiation
    Rojas-Mantilla, Hernan Dario
    Irikura, Kallyni
    de Souza, Joao Carlos
    Ayala-Duran, Saidy Cristina
    Gomes, Paulo Clairmont Feitosa de Lima
    Salazar-Gonzalez, Ricardo
    Zanoni, Maria Valnice Boldrin
    CHEMICAL ENGINEERING JOURNAL, 2023, 477