Effects of combretastatin on murine tumours monitored by 31P MRS, 1H MRS and 1H MRI

被引:34
|
作者
Maxwell, RJ
Nielsen, FU
Breidahl, T
Stodkilde-Jorgensen, H
Horsman, MR
机构
[1] Gray Lab Canc Res Trust, Northwood, Middx, England
[2] Skejby Univ Hosp, MR Ctr, Aarhus, Denmark
[3] Univ Aarhus, Dept Expt Clin Oncol, Danish Canc Soc, Aarhus, Denmark
关键词
magnetic resonance imaging; magnetic resonance spectroscopy; combretastatin; tumour vasculature;
D O I
10.1016/S0360-3016(98)00359-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Combretastatins have tubulin-binding activity and are being investigated for their toxicity against tumour vasculature. We report the use of P-31 and H-1 magnetic resonance (MR) spectroscopy and H-1 MR imaging for monitoring the effects of combretastatin A-4 prodrug (100mg/kg, i.p.) on energy metabolism and necrosis, respectively, in the C3H murine mammary tumour, Materials and Methods: The tumours (volume ca, 200mm(3)) were grown in the hind foot of mice, MR examinations were performed without anaesthesia within a 7.1 Tesla magnet. (31)p MRS (TR = 6 s) was performed before treatment and at 1-, 2-, 3-, and 24-h after injection of drug or saline via an i.p. line. H-1 MRS (PRESS; 24 mu l voxel; TR = 2 s; TE = 135 ms) and both T-1-weighted (TR = 0.2 s; TE = 0.02 s) and T-2-weighted (TR = 2 s; TE = 0.20 s) H-1 MRI were performed before treatment and 2.5 and 24 h afterwards. Results: The ratio P-nucleotide triphosphate/inorganic phosphate fell by 33% within 1 h of treatment and remained constant for a further 2 h, A small but significant fall in pH (by 0.11 units) was observed at 1 h, Although an increase in the H-1 MR spectroscopy signal at about 1.32 ppm (predominantly from lactate) was observed in some tumours following combretastatin treatment, this effect was not seen consistently, No changes in the intensity of T-3-weighted H-1 MR images or in tumour necrosis (measured histologically) were detected within 3 h of treatment. Conclusions: The reduction in tumour energetics and pH was consistent with a reduction in tumour blood flow but this occurred before any significant incidence of haemorrhagic necrosis was detected. The combretastatin dose used to achieve these effects was less than one tenth of the maximum tolerated dose in mice. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:891 / 894
页数:4
相关论文
共 50 条
  • [31] Body Composition in Premature Adrenarche by Structural MRI, 1H MRS and DXA
    Leibel, Natasha
    Shen, Wei
    Mao, Xiangling
    Punyanitya, Mark
    Gallagher, Dympna
    Horlick, Mary
    Shungu, Dikoma C.
    Oberfield, Sharon E.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2009, 22 (04): : 301 - 307
  • [32] Assessment of Muscle Injury Using Diffusion Kurtosis MRI and 1H MRS
    Lovering, Richard M.
    Iyer, Shama R.
    Zhuo, Jiachen
    Roys, Steven
    Zhu, Wenjun
    Xu, Su
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 425 - 425
  • [33] MRI and 1H MRS findings in Smith-Lemli-Opitz syndrome
    P. A. Caruso
    T. Y. Poussaint
    A. A. Tzika
    D. Zurakowski
    L. G. Astrakas
    E. R. Elias
    C. Bay
    M. B. Irons
    Neuroradiology, 2004, 46 : 3 - 14
  • [34] Combined 1H MRI, PET and Multinuclear MRS hybrid imaging system
    Janusz H Hankiewicz
    Zbigniew Celinski
    Kevin Smiley
    Stan Majewski
    EJNMMI Physics, 1 (Suppl 1)
  • [35] 1H MAS and 1H → 31P CP/MAS NMR study of human bone mineral
    Kaflak-Hachulska, A
    Samoson, A
    Kolodziejski, W
    CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (05) : 476 - 486
  • [36] 1H MAS and 1H → 31P CP/MAS NMR Study of Human Bone Mineral
    A. Kaflak-Hachulska
    A. Samoson
    W. Kolodziejski
    Calcified Tissue International, 2003, 73 : 476 - 486
  • [37] 187Os subspectra in 1H and 31P{1H} spectra of triosmium carbonyl clusters
    Stchedroff, MJ
    Aime, S
    Gobetto, R
    Salassa, L
    Nordlander, E
    MAGNETIC RESONANCE IN CHEMISTRY, 2002, 40 (02) : 107 - 113
  • [38] Towards a method for automated classification of 1H MRS spectra from brain tumours
    Tate, AR
    Griffiths, JR
    Martinez-Perez, I
    Moreno, A
    Barba, I
    Cabanas, ME
    Watson, D
    Alonso, J
    Bartumeus, F
    Isamat, F
    Ferrer, I
    Vila, F
    Ferrer, E
    Capdevila, A
    Arus, C
    NMR IN BIOMEDICINE, 1998, 11 (4-5) : 177 - 191
  • [39] Comparison of in vivo 1H MRS of human brain tumours with 1H HR-MAS spectroscopy of intact biopsy samples in vitro
    Barton, Sarah J.
    Howe, Franklyn A.
    Tomlins, Andrew M.
    Cudlip, Simon A.
    Nicholson, Jeremy K.
    Bell, B. Anthony
    Griffiths, John R.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 8 (02) : 121 - 128
  • [40] Dynamic interleaved 1H/31P STEAM MRS using a pneumatic force-controlled plantar flexion exercise rig
    Meyerspeer, M
    Krssák, M
    Kemp, GJ
    Roden, M
    Moser, E
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (05) : 257 - 262