A study to determine the sensitivity and specificity of hospital discharge diagnosis data used in the MICA study

被引:0
|
作者
McAlpine, R
Pringle, S
Pringle, T
Lorimer, R
MacDonald, TM
机构
[1] Ninewells Hosp, Med Monitoring Unit MEMO, Dundee DD1 9SY, Scotland
[2] Ninewells Hosp, Dept Cardiol, Dundee DD1 9SY, Scotland
[3] Glasgow Royal Infirm, Dept Cardiol, Glasgow G4 0SF, Lanark, Scotland
关键词
myocardial infarction; Scottish morbidity record 1; International Classification of Diseases 9; the MICA study;
D O I
10.1002/(SICI)1099-1557(199809/10)7:5<311::AID-PDS371>3.0.CO;2-O
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Aims - To determine the sensitivity and specificity of each ICD9 code for a diagnosis of definite or possible myocardial infarction (MI) from the perspective of the Myocardial Infarction Causality Study (MICA) and to use these data to estimate the likely number of MICA cases in Scotland that would be undetected were these codes omitted from the study. Setting - Women resident and registered with general practitioners in the Tayside region of Scotland between October 1993 and October 1995. Method - All SMR1 records of Tayside hospitalizations containing ICD9 (International Classification of Diseases, ninth revision) codes for myocardial infarction (410) or possible myocardial infarction (411, 412, 413, 414, 427.4, 427.5, 786.5) were identified for women aged between 16 and 44 years between 1 October 1993 and 15 October 1995. Original case records were sought and each episode abstracted using a predefined form. Records were independently scrutinized by two consultant cardiologists blinded to the SMR1 code. Cases were categorized as definite MI, possible MI or unlikely MI. Where there was disagreement between the two cardiologists, the profiles for such events were examined by a third cardiologist who acted as the final adjudicator. The adjudicator's verdict was, in this study, considered dominant. The sensitivity, specificity and positive predictive value of each ICD9 code was determined. Results - Two hundred and fifty-three women fulfilled the SMR1 search criteria. Case records of 204 (81%) were retrieved but four case records contained no data on the admission of interest and were classified as invalid. Forty-six of the 200 remaining patients were ineligible for the MICA study leaving 154 records for evaluation. There were 12 patients who had a discharge code for MI (ICD9 410). Of these, 1 1 were judged as a definite MI by both cardiologists. One event (discharge code ICD9 410) was judged as 'possible' by one cardiologist and 'unlikely' by the other. The adjudicator subsequently judged this event as 'definite'. Another six events were subsequently judged as 'possible'. Thus, after adjudication, 12 cases of definite MI and six cases of 'possible' MI were identified. The sensitivity and specificity of ICD9 code 410 was 67% and 100% respectively. The positive predictive value was 100%. The sensitivity of code 411 was 5.6%. The specificity was 99% and the positive predictive value was 50%. Code 413 had a sensitivity of 5.6% with a specificity of 94% and a positive predictive value of 9.1%. Code 414 also had a sensitivity of 5.6%. The specificity was 86% and the positive predictive value was 4.5%. Code 786.5 had a sensitivity of 17%, a specificity of 23% and a positive predictive value of 2.5%. Code 427.5 failed to identify any definite or possible cases. Conclusions - In the MICA Study, ICD9 code 410 was found to be the most robust. All 12 patients judged to have had a definite MI had the appropriate discharge code (ICD9 410). The six patients judged to have had a possible MI all had discharge codes other than that for MI (410). However, identifying these six patients required the validation of a further 160 events - giving a combined sensitivity of 33%, a specificity of 0% and a positive predictive value of only 3.8%. The use of ICD9 codes 411, 413, 414, 427.5 and 786.5 must, therefore, only be employed when circumstances fully justify the additional workload. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [1] Can hospital discharge diagnosis be used for surveillance of bacteremia? A data quality study of a Danish hospital discharge registry
    Madsen, KM
    Schonheyder, HC
    Kristensen, B
    Nielsen, GL
    Sorensen, HT
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1998, 19 (03): : 175 - 180
  • [2] The quality of hospital discharge data used for injury surveillance
    Ewert, U. P.
    Segui-Gomez, M.
    [J]. EUROPEAN JOURNAL OF PUBLIC HEALTH, 2007, 17 : 60 - 61
  • [3] Can hospital discharge data be used for monitoring indicators associated with postpartum hemorrhages? The HERA multicenter observational study
    Crenn-Hebert, C.
    Barasinski, C.
    Debost-Legrand, A.
    Da Costa-Correia, C.
    Riviere, O.
    Fresson, J.
    Vendittelli, F.
    [J]. JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2018, 47 (04) : 145 - 150
  • [4] Sensitivity and specificity of immunohistochemical markers used in the diagnosis of epithelioid mesothelioma: a detailed systematic analysis using published data
    King, JE
    Thatcher, N
    Pickering, CAC
    Hasleton, PS
    [J]. HISTOPATHOLOGY, 2006, 48 (03) : 223 - 232
  • [5] CONCORDANCE BETWEEN HOSPITAL DISCHARGE DATA, ELECTRONIC HEALTH RECORDS AND REGISTER BOOKS FOR DIAGNOSIS OF MISCARRIAGE IN A TERTIARY MATERNITY HOSPITAL: A RETROSPECTIVE LINKED DATA STUDY
    Campillo, I. S. C. L. San Lazaro
    Meaney, S. M.
    Harrington, M. H.
    Verling, A. M. V.
    Corcoran, P. C.
    O'Donogue, K. O. D.
    [J]. JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2019, 73 : A50 - A50
  • [6] Neuralgic amyotrophy: sensitivity and specificity of magnetic resonance neurography in diagnosis: A retrospective study
    Duan, Luyao
    Zhao, Liyang
    Liu, Ying
    Zhang, Yizhe
    Zheng, Wensong
    Yu, Xiaoman
    Liu, Hongran
    Li, Zequn
    Peng, Zhigang
    Li, Xiaona
    [J]. MEDICINE, 2023, 102 (43) : E35527
  • [7] STUDY OF THE SENSITIVITY AND SPECIFICITY OF THE IMMUNOPHENOTYPE OF MONOCITARY POPULATIONS FOR THE DIAGNOSIS OF CHRONIC MYELOMONOCYTIC LEUKEMIA
    Risco, Galvez Irene
    Benet, Campos Carmen
    Alonso, Prieto Carmen
    Tejada, Chaves Christian
    Garces, Piquer Sonia
    Marti, de Talavera Jaime
    Valero, Nunez Marta
    Lorente, Alegre Pablo
    Lopez, Martinez Aurelio
    Mas, Ochoa Carmen
    Lopez, Chulia Francisca
    Hueso, Alejandro
    [J]. HAEMATOLOGICA, 2020, 105 : 178 - 179
  • [8] The sensitivity and specificity of confocal microscopy in the diagnosis of allergic contact dermatitis:: a preliminary study
    Astner, S
    Cheung, AC
    Gonzalez, E
    Rius-Díaz, F
    Doukas, AG
    Gonzalez, S
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2004, 122 (03) : A47 - A47
  • [9] A pilot study to assess the sensitivity and specificity of an intrasound device in the diagnosis of ankle fractures
    Dancocks, A
    Rouse, A
    Hiscox, J
    [J]. JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1997, 14 (04): : 230 - 232
  • [10] Sensitivity and Specificity of the Minimum Data Set 3.0 Discharge Data Relative to Medicare Claims
    Rahman, Momotazur
    Tyler, Denise
    Acquah, Joseph Kofi
    Lima, Julie
    Mor, Vincent
    [J]. JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2014, 15 (11) : 819 - 824