A study of the "wall effect" caused by proliferation of high-rise buildings using GIS techniques

被引:86
|
作者
Wong, Man Sing [1 ]
Nichol, Janet [1 ]
Ng, Edward [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Land Surveying & Geoinformat, Kowloon, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Architecture, Hong Kong, Hong Kong, Peoples R China
关键词
Frontal area index; Geographic Information Systems; Thermal remote sensing; Ventilation; Wall effect; URBAN HEAT-ISLAND; DISPERSION;
D O I
10.1016/j.landurbplan.2011.05.003
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
This paper describes a novel method using Geographic Information Systems (GIS) to investigate the "wall effect" caused by proliferation of high-rise buildings along the coast in Kowloon Peninsula of Hong Kong. The research utilises the concept of building frontal area index which is calculated based on three dimensional buildings in 100 m grid cells. The main ventilation pathways across the urban area are located using Least Cost Path analysis in a raster GIS and validated by field measurements. Field measurements were also taken in front of windward and leeward buildings. Results show that winds are forced by high frontal area values, to deviate around coastlines with blocks of "wall effect" buildings parallel to the coast. Average wind speeds of 10.5 m s(-1) were observed on the windward side of "wall effect" buildings defined according to a southeasterly wind direction, while average wind speeds immediately to the lee side of "wall effect" buildings as well as further inland, were approximately 2.5 m s(-1) (four times lower). To confirm the "wall effect" hypothesis, scenario analysis was performed by removing these buildings from the model and re-running it. This revealed a 5% increase of air ventilation to urban areas inland, since more fresh onshore air is able to penetrate from the coast. This improvement is significant since only 0.05% of buildings in the study area were removed. Overlay of the ventilation pathways over a thermal satellite image representing Heat Island Intensity (HII) indicated significantly lower HII values, and reduced extent of the core HI I areas, around the ventilation paths. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [41] ORIGIN AND EVOLUTION OF HIGH-RISE BUILDINGS
    Parasonis, Josifas
    Gaudutis, Ernestas
    JOURNAL OF ARCHITECTURE AND URBANISM, 2009, 33 (03) : 158 - 172
  • [42] Thinking of High-Rise Buildings Design
    Feng, Xiang
    Guo, Yanli
    PROCEEDINGS OF THE 2013 INTERNATIONAL WORKSHOP ON COMPUTER SCIENCE IN SPORTS, 2013, : 202 - 205
  • [43] Solar considerations in high-rise buildings
    Lotfabadi, Pooya
    ENERGY AND BUILDINGS, 2015, 89 : 183 - 195
  • [44] TORSIONAL RESPONSE OF HIGH-RISE BUILDINGS
    HART, GC
    DIJULIO, RM
    LEW, M
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1975, 101 (NST2): : 397 - 416
  • [45] EXTERIOR ACCESS TO HIGH-RISE BUILDINGS
    不详
    FIRE ENGINEERING, 1985, 138 (06) : 72 - &
  • [46] High-rise buildings and environmental factors
    Lotfabadi, Pooya
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 38 : 285 - 295
  • [47] High-rise buildings worsened heatwave
    Cheema, Abdur Rehman
    NATURE, 2015, 524 (7563) : 35 - 35
  • [48] Seismic instrumentation of high-rise buildings
    Katayoun B. Aafshar
    Dragi Dojcinovski
    Progress in Natural Science:Materials International, 2009, 19 (02) : 223 - 227
  • [49] SEISMIC ASSESSMENT OF HIGH-RISE BUILDINGS
    WANG, PC
    DRENICK, RF
    WANG, WYL
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1978, 104 (02): : 441 - 456
  • [50] High-rise buildings worsened heatwave
    Abdur Rehman Cheema
    Nature, 2015, 524 : 35 - 35