Wearable transdermal colorimetric microneedle patch for Uric acid monitoring based on peroxidase-like polypyrrole nanoparticles

被引:32
|
作者
Zhang, Pingping [1 ]
Wu, Xiao [1 ]
Xue, Hongmei [2 ]
Wang, Yuchen [1 ]
Luo, Xiliang [1 ]
Wang, Lei [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn,Shandong Key Lab Biochem Ana, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Minist Educ,Key Lab Analyt Chem Life Sci Univ Sha, Qingdao 266042, Peoples R China
[2] Qingdao Woman & Childrens Hosp, P, Qingdao 266000, Peoples R China
基金
中国国家自然科学基金;
关键词
Uric acid sensor; Transdermal sensor patch; Microneedle; Point-of-care testing; Colorimetric sensor; IN-VIVO; FLUORESCENT; BIOSENSOR; ENZYME;
D O I
10.1016/j.aca.2022.339911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Regular Uric Acid (UA) monitoring is essential for patients with gout, and great efforts have been made to develop portable, low-cost and easy-to-operate UA detection technologies. Herein, we developed a wearable microneedle colorimetric patch integrating the sampling function and the capability of real-time UA analysis in a minimally invasive manner, which can dramatically improve patient compliance. For the operation of the constructed device, the poly(vinyl alcohol) based microneedle was embedded with the uricase which catalyzed the oxidation of UA extracted from the interstitial fluids and produced H2O2. Polypyrrole nanoparticles (PPy NPs) with peroxidase-like activity encapsulated in the display layer triggered the reaction between H2O2 and 3,3',5,5'- tetramethylbenzidine, resulting in the color variation associated with the concentration of H2O2 produced by the UA oxidation. Thus, the UA level can be determined with the naked eye. According to the relationship between the color intensity and the UA concentration, the UA level within the range of 200-1000 mu M can be further quantified accurately by analyzing sample images with a smart phone. The developed device exhibited good selectivity and stability, and a limit of detection of about 65 mu M. This wearable device holds great potential in health management and clinical point-of-care detection.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Enhanced peroxidase-like activity of MnFe2O4 nanoparticles on halloysite nanotubes for uric acid detection
    Shen, Hengxia
    Xiang, Zhenbo
    Dang, Anfang
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [42] Colorimetric detection of sulfide based on target-induced shielding against the peroxidase-like activity of gold nanoparticles
    Deng, Hao-Hua
    Weng, Shao-Huang
    Huang, Shuang-Lu
    Zhang, Ling-Na
    Liu, Ai-Lin
    Lin, Xin-Hua
    Chen, Wei
    ANALYTICA CHIMICA ACTA, 2014, 852 : 218 - 222
  • [43] Colorimetric evaluation of total antioxidant capacity based on peroxidase-like nonstoichiometric Cu2-xSe nanoparticles
    Ni, Huanhuan
    Li, Xiaoxiao
    Yan, Guojuan
    Huang, Chengzhi
    Zou, Hongyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [44] Colorimetric sensor based on dual-functional gold nanoparticles: Analyte-recognition and peroxidase-like activity
    Deng, Hao-Hua
    Li, Guang-Wen
    Hong, Lei
    Liu, Ai-Lin
    Chen, Wei
    Lin, Xin-Hua
    Xia, Xing-Hua
    FOOD CHEMISTRY, 2014, 147 : 257 - 261
  • [45] Peroxidase-like activity of nanocrystalline cobalt selenide and its application for uric acid detection
    Zhuang, Quan-Quan
    Lin, Zhi-Hang
    Jiang, Yan-Cheng
    Deng, Hao-Hua
    He, Shao-Bin
    Su, Li-Ting
    Shi, Xiao-Qiong
    Chen, Wei
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 3295 - 3302
  • [46] Colorimetric detection of neomycin sulfate in serum based on ultra-small gold nanoparticles with peroxidase-like activity
    Zang, Wen
    Peng, Minjie
    Yang, Yiyu
    Zhang, Chenguang
    Liu, Zhusheng
    Wang, Le
    Wang, Chaozhen
    Lin, Jie
    Chen, Tianxiang
    Zhang, Yujie
    Li, Juan
    Wu, Aiguo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 321
  • [47] Colorimetric quantification and discrimination of phenolic pollutants based peroxidase-like Fe3O4 nanoparticles
    Wu, Shuwen
    Guo, Danzhao
    Xu, Xuechao
    Pan, Jianming
    Niu, Xiangheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 303
  • [48] Colorimetric Detection of Hg2+ Based on Enhancement of Peroxidase-like Activity of Chitosan-Gold Nanoparticles
    Jiang, Cuifeng
    Li, Zhuojian
    Wu, Yinxing
    Guo, Wei
    Wang, Jinshan
    Jiang, Qiong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2018, 39 (05): : 625 - 630
  • [49] Peroxidase-like Nanozyme Composite-based Colorimetric Determination of Glutathione and Cysteine
    Zhang, Wengan
    Chen, Binjie
    Wang, Ruke
    Liu, Jing
    Wang, Bo
    ANALYTICAL LETTERS, 2024, 57 (08) : 1271 - 1281
  • [50] Phosphorus Modulated Peroxidase-Like Activity of Carbon Dots for Colorimetric Detection of Acid Phosphatase
    Zhang, Yongmei
    Liang, Haibo
    Wang, Xinru
    Yu, Ying
    Cao, Yujuan
    Guo, Manli
    Lin, Bixia
    APPLIED SPECTROSCOPY, 2024, 78 (06) : 633 - 643