Scanning Aged CR-39 SSNTDs with Etched Alpha Tracks by Using Transmitted Laser Light

被引:6
|
作者
Saad, A. F. [1 ]
El-Namrouty, A. A. [1 ]
Solyman, S. [1 ]
Atwa, S. T. [2 ]
机构
[1] Zagazig Univ, Dept Phys, Fac Sci, Zagazig 44519, Egypt
[2] Banha Univ, Dept Chem, Fac Sci, Banha 13511, Egypt
关键词
CR-39; Optical density; Etched-alpha tracks; He-Ne laser transmission; Storage conditions; DETECTORS; TRANSMISSION; DENSITY;
D O I
10.3938/jkps.58.701
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The optical track scanning method is based on the measurement of laser light transmission through CR-39 solid state nuclear track detectors (SSNTDs). Etched tracks in CR-39 SSNTDs are used to examine the degree of linear correlation between the tracks observed using an optical microscope and those measured by using the laser light transmission (LLT) method. The intensity of the light transmitted through the etched tracks was measured using a photodiode. The present investigation clearly indicates that the results from the LLT method depend on track density and alpha energy, as well as the etching and storage conditions of the detector material. In addition, the transmittance of laser light through the etched CR-39 detectors aged at room temperature is found to be relatively small compared with that of those kept in a freezer. This technique was tested on the overlap of tracks in SSNTD radon dosimetry by using a standard exposure. The results show that the radon dose can be rapidly estimated.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [41] Studies of isochronal and isothermal annealing of alpha particle tracks in CR-39 polymer detectors
    Pinheiro, JD
    DaSilva, AX
    Santos, RC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 111 (1-2): : 104 - 110
  • [42] Studies of isochronal and isothermal annealing of alpha particle tracks in CR-39 polymer detectors
    Universidade Federal Fluminense, Rio de Janeiro, Brazil
    Nucl Instrum Methods Phys Res Sect B, 1-2 (104-110):
  • [43] V-function to investigate tracks of the alpha particle irradiated CR-39 detector
    Al-Jubbori, Mushtaq Abed
    RADIATION MEASUREMENTS, 2020, 136 (136)
  • [44] THERMAL-NEUTRON DOSIMETRY USING ELECTROCHEMICALLY ETCHED CR-39 DETECTOR
    ILIC, R
    KRISTOF, ES
    DIJANOSIC, R
    SKVARC, J
    DOBNIKAR, R
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 453 - 456
  • [45] Radon track imaging in CR-39 plastic detectors using confocal scanning laser microscopy
    Petford, N
    Wertheim, D
    Miller, JA
    JOURNAL OF MICROSCOPY, 2005, 217 : 179 - 183
  • [46] Evolution of etched nuclear track profiles of alpha particles in CR-39 by atomic force microscopy
    Felix-Bautista, R.
    Hernandez-Hernandez, C.
    Zendejas-Leal, B. E.
    Fragoso, R.
    Golzarri, J. I.
    Vazquez-Lopez, C.
    Espinosa, G.
    RADIATION MEASUREMENTS, 2013, 50 : 197 - 200
  • [47] Registration of alpha particles using CR-39 nuclear detector
    Abdalla, Ayman M.
    Al-Naggar, Tayseer I.
    Alhandhal, Rayah H.
    Albargi, Hasan B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [48] Particularization of alpha contamination using CR-39 track detectors
    M. F. Zaki
    Y. H. El-Shaer
    Pramana, 2007, 69 : 567 - 574
  • [49] Determination of alpha activity in organic solvents using CR-39
    Joshirao, Pranav M.
    Vyas, Chirag K.
    Kim, Taesung
    Kalsi, Puran C.
    Manchanda, Vijay K.
    APPLIED RADIATION AND ISOTOPES, 2013, 78 : 68 - 71
  • [50] Particularization of alpha contamination using CR-39 track detectors
    Zaki, M. F.
    El-Shaer, Y. H.
    PRAMANA-JOURNAL OF PHYSICS, 2007, 69 (04): : 567 - 574