Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

被引:16
|
作者
Ma, Ji [1 ]
Han, Xinwei [1 ]
Wu, Gang [1 ]
Jiao, Dechao [1 ]
Ren, Kewei [1 ]
Bi, Yonghua [1 ]
机构
[1] Zhengzhou Univ, Dept Intervent Radiol, Affiliated Hosp 1, 1 Jianshe Rd East, Zhengzhou 450000, Henan, Peoples R China
关键词
Stents; Tracheobronchial stenosis; Bronchoscopy; Device removal; BRONCHIAL STENOSIS; AIRWAY STENOSIS; METALLIC STENT; SILICONE STENT; OBSTRUCTION; MANAGEMENT; TOLERANCE; DISEASE;
D O I
10.1007/s00270-016-1353-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis. We conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal. A total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 +/- A 0.495 and 25.352 +/- A 10.533, respectively) compared with those before stent placement (1.493 +/- A 0.504 and 60.140 +/- A 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 +/- A 3.457 and 8.993 +/- A 0.961 mm; 1 month post-removal; 16.353 +/- A 4.132 and 8.357 +/- A 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 +/- A 2.351 and 2.143 +/- A 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05). Temporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.
引用
收藏
页码:1144 / 1151
页数:8
相关论文
共 50 条
  • [31] Immediate Placement of a Temporary Covered Stent for the Management of Iatrogenic Malignant Esophageal Perforation
    Hu, Hong-Tao
    Song, Ho-Young
    Kim, Jin Hyoung
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (04) : 886 - 888
  • [32] Treatment of congenital tracheal stenosis with balloon-assisted posterior tracheal splitting and temporary placement of a covered retrievable metallic stent
    Kim, HJ
    Shin, JH
    Hong, SJ
    Park, SJ
    Lee, SY
    Song, HY
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (02) : 287 - 291
  • [33] Temporary non-flared fully covered self-expandable metal stent placement for refractory benign choledochojejunal anastomotic stricture
    Yamauchi, Hiroshi
    Tadehara, Masayoshi
    Kida, Mitsuhiro
    DIGESTIVE ENDOSCOPY, 2018, 30 (04) : 541 - 542
  • [34] Early covered-stent fracture after placement for a benign esophageal stricture
    Wadsworth, Christopher A.
    East, James E.
    Hoare, Jonathan M.
    GASTROINTESTINAL ENDOSCOPY, 2010, 72 (06) : 1260 - 1261
  • [35] Covered Stent Placement for Subclavian Vein Stenosis Associated With Basilic Arteriovenous Fistula
    Rivera, Diana M. Torpoco
    Taylor, Rachel
    Fox, Andrew
    Forbes, Thomas J.
    Kobayashi, Daisuke
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2022, 13 (02) : 248 - 251
  • [36] Systematic review: temporary stent placement for benign rupture or anastomotic leak of the oesophagus
    van Boeckel, P. G. A.
    Sijbring, A.
    Vleggaar, F. P.
    Siersema, P. D.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2011, 33 (12) : 1292 - 1301
  • [37] TEMPORARY PLACEMENT OF WALLFLEX FULLY COVERED SELF-EXPANDABLE METALLIC STENT (WFCSEMS) IN BENIGN BILIARY STENOSIS (BBS) IN PREVIOUSLY UNSUCCESSFUL COMMON BILE DUCT PLASTIC STENTING: MIDTERM EVALUTION
    Ayoubi, M.
    Sansoe, G.
    Leone, N.
    Framarin, L.
    Badalamenti, S.
    Castellino, F.
    DIGESTIVE AND LIVER DISEASE, 2011, 43 : S255 - S255
  • [38] The role of airway stent placement in the management of tracheobronchial stenosis caused by inoperable advanced lung cancer
    Furukawa, Kinya
    Ishida, Junzo
    Yamaguchi, Gaku
    Usuda, Jitsuo
    Tsutsui, Hidemitsu
    Saito, Makoto
    Konaka, Chimori
    Kato, Harubumi
    SURGERY TODAY, 2010, 40 (04) : 315 - 320
  • [39] Bougienage and balloon dilation using a conventional tracheal tube for tracheobronchial stenosis before stent placement
    Nomori, H
    Horio, H
    Suemasu, K
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2000, 14 (06): : 587 - 591
  • [40] The role of airway stent placement in the management of tracheobronchial stenosis caused by inoperable advanced lung cancer
    Kinya Furukawa
    Junzo Ishida
    Gaku Yamaguchi
    Jitsuo Usuda
    Hidemitsu Tsutsui
    Makoto Saito
    Chimori Konaka
    Harubumi Kato
    Surgery Today, 2010, 40 : 315 - 320