Intra-aortic balloon pumping: effects on left ventricular diastolic function

被引:27
|
作者
Khir, AW
Price, S
Henein, MY
Parker, KH
Pepper, JR
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[2] Royal Brompton & Natl Heart Hosp, Echocardiog Dept, London SW3 6NP, England
关键词
intra-aortic balloon pump; diastolic function; coronary flow; mitral flow;
D O I
10.1016/S1010-7940(03)00268-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The intra-aortic balloon pump is the most widely used form of temporary cardiac assist and often utilised in patients before and after cardiac surgery. Several effects of balloon counter-pulsation have been reported previously, but its effect on left ventricular diastolic function has not been thoroughly investigated. The aim of this study is to examine the effect of the intra-aortic balloon pump on left ventricular wall motion and transmittal flow. Methods: We studied 20 patients in the intensive care unit, less than 36 It following cardiac surgery. We recorded left anterior descending coronary artery and transmitral E-wave flow velocities using transesophageal echocardiography pulsed Doppler. We also recorded left ventricular long axis free-wall movement using M-mode. The intra-aortic balloon pump was set to full augmentation and recordings were made at pumping cycles 1: 1, 1:2, 1:3, and when the pump was on stand-by, leaving a minimum of 5 min between the pumping modes to allow the return to control conditions. In order to eliminate time effects, the sequence of recording was varied between patients using a 4 by 4 Latin-square. Results: The peak diastolic left anterior descending coronary artery and transmitral E-wave flow velocities, and left ventricular free-wall early diastolic lengthening velocity increased significantly with intra-aortic balloon pumping cycles 1: 1, 1:2 and 1:3 compared to their value with the pump on stand-by, all P < 0.001. The increase in peak transmitral E-wave flow velocity correlated with the increase in peak left anterior descending coronary artery diastolic flow velocity (r = 0.74, P = 0.02), and with the increase in left ventricular free-wall early diastolic lengthening velocity (r = 0.80, P < 0.001). Conclusion: Using the intra-aortic balloon pump post-cardiac surgery significantly increases peak diastolic left anterior descending coronary artery flow velocities and left ventricular free-wall early diastolic lengthening velocity, whose increase explains the increase in peak transmitral E-wave velocity. Although coronary flow is epicardial and mitral flow is intracardial, their close relationship suggests an improvement in left ventricular diastolic function with intra-aortic balloon pump. (C) 2003 Elsevier Science B.V. All fights reserved.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [11] INTRA-AORTIC BALLOON PUMPING
    HARRISON, GA
    ANAESTHESIA AND INTENSIVE CARE, 1979, 7 (01) : 89 - 89
  • [12] INTRA-AORTIC BALLOON PUMPING
    WEBER, KT
    JANICKI, JS
    ANNALS OF INTERNAL MEDICINE, 1972, 77 (03) : 477 - +
  • [13] INFLUENCE OF INTRA-AORTIC BALLOON PULSATION ON LEFT-VENTRICULAR FUNCTION
    BLANKE, H
    KARSCH, K
    KREUZER, H
    DEVIVIE, ER
    RENTROP, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1978, 67 (03): : 213 - 213
  • [14] INTRA-AORTIC BALLOON PUMPING AND COUNTERPULSATION
    MOULOPOULOS, SD
    AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (07): : 1115 - 1115
  • [15] DIASTOLIC AUGMENTATION BY INTRA-AORTIC BALLOON
    BROWN, BG
    GOLDFARB, D
    GOTT, VL
    CIRCULATION, 1967, 36 (4S2) : II77 - &
  • [16] INTRA-AORTIC BALLOON PUMPING IN CHILDREN
    POLLOCK, JC
    CHARLTON, MC
    WILLIAMS, WG
    EDMONDS, JF
    TRUSLER, GA
    ANNALS OF THORACIC SURGERY, 1980, 29 (06): : 522 - 528
  • [17] PERCUTANEOUS INTRA-AORTIC BALLOON PUMPING
    SUBRAMANIAN, VA
    ANNALS OF THORACIC SURGERY, 1980, 29 (02): : 102 - 103
  • [18] PERCUTANEOUS INTRA-AORTIC BALLOON PUMPING
    BREGMAN, D
    WEISS, MB
    CASARELLA, WJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 395 - 395
  • [19] PURPOSE OF INTRA-AORTIC BALLOON PUMPING
    MOULOPOULOS, SD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 72 (05): : 817 - 818
  • [20] RESPONSE TO INTRA-AORTIC BALLOON PUMPING
    FOSTER, ED
    SUBRAMANIAN, VA
    VITO, L
    HECHTMAN, HB
    BERGER, RL
    AMERICAN JOURNAL OF SURGERY, 1975, 129 (04): : 464 - 471