Flow-injection spectrophotometric determination of paraoxon by its inhibitory effect on the enzyme acetylcholinesterase

被引:5
|
作者
Rodrigues, TC
Tubino, M
Godinho, OES
Neto, GD
机构
[1] Univ Estadual Campinas, UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
[2] Univ Integradas Triangulo, Dept Quim, Uberlandia, MG, Brazil
[3] Univ Sao Francisco, Ctr Ciencias Biol & Saude, BR-12900000 Braganca Paulista, SP, Brazil
关键词
D O I
10.2116/analsci.17.629
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A spectrophotometric enzymatic flow injection (FI) system for the determination of diethyl-p-nitrophenylphosphate (paraoxon) is proposed. The method was based on the determination of the acetic acid formed by the enzymatic reaction of the acetylcholinesterase, immobilized on glass beads, with the substrate acetylcholine. The acetic acid formed permeates through a PTFE membrane and is received by a solution (pH 7.0) containing the acid-base indicator Bromocresol Purple (B. C. P.), leading to a pH change and therefore to a color change. The variation of the absorbance of the solution is detected spectrophotometrically at 400 nm. The determination of paraoxon is related to its inhibitory action on the enzyme. Therefore the analytical signal is the difference between the signal that corresponds to the free and the one that corresponds to the inhibited enzyme, considering a Bred acetylcholine concentration. The correlation between the peak height and paraoxon concentration at a given acetylcholine concentration is linear in the range from 5.0 x 10(-7) mol L(-1) to 5.0 x 10(-5) mol L(-1) (r = 0.998) of paraoxon, with a relative estimated standard deviation (R.S.D.) of +/-1.7% (n = 10) considering a solution containing 5.0 x 10(-6) mol L-l of paraoxon and a solution containing 5.0 x 10(-3) mol L-l of acetylcholine. Therefore, the quantitative limit detection is about 2.5 x 10(-7) mol L(-1) of paraoxon (3 sigma). A 1,1 ' -trimethylene-bis(4-formylpyridinium bromide)dioxime (TMB-4) solution was used to reactivate the enzyme.
引用
收藏
页码:629 / 633
页数:5
相关论文
共 50 条
  • [31] FLOW-INJECTION ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF NICKEL
    SHPIGUN, LK
    KOLOTYRKINA, IY
    ZOLOTOV, YA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1986, 41 (07): : 925 - 928
  • [32] FLOW-INJECTION DETERMINATION OF OXALATE IN URINE BASED ON AN INHIBITORY EFFECT
    INFANTES, JA
    DECASTRO, MDL
    VALCARCEL, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (01): : 58 - 61
  • [33] SPECTROPHOTOMETRIC DETERMINATION OF MAGNESIUM IN SERUM BY USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME REACTOR
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    VALCARCEL, M
    QUILESZAFRA, R
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 447 - 452
  • [34] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF SODIUM-NITROPRUSSIDE
    ALWEHAID, AM
    ANALYTICAL LETTERS, 1991, 24 (04) : 589 - 601
  • [35] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF LYSINE IN FEED SAMPLES
    SAURINA, J
    HERNANDEZCASSOU, S
    ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 593 - 600
  • [36] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF NITRITE IN WATER SAMPLES
    YAQOOB, M
    SIDDIQUI, MA
    MASOOM, M
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1992, 69 (01) : 32 - 33
  • [37] Development of POF Flow-Injection for Spectrophotometric Determination of Nitrite
    Abubakar, Sabiran
    Arsad, Norhana
    Nadia, Sayidatul
    Ehsan, Abang Annuar
    Ab-Rahman, Mohammad Syuhaimi
    Arsad, Norlimah
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA 2013), 2013,
  • [38] Spectrophotometric flow-injection determination of nickel in biological materials
    Vicente, S
    Maniasso, N
    Queiroz, ZF
    Zagatto, EAG
    TALANTA, 2002, 57 (03) : 475 - 480
  • [39] KINETIC FLOW-INJECTION DETERMINATION OF CARBONATE WITH SPECTROPHOTOMETRIC DETECTION
    SHLYAMIN, VI
    OBREZKOV, ON
    SHPIGUN, OA
    ZOLOTOV, YA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (01): : 55 - 57
  • [40] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF ASPARTAME IN DIETARY PRODUCTS
    NOBREGA, JD
    FATIBELLO, O
    VIEIRA, ID
    ANALYST, 1994, 119 (09) : 2101 - 2104