IMRT QA via MapCHECK a 2D diode detector system

被引:0
|
作者
Cullip, T [1 ]
Chang, S [1 ]
机构
[1] Univ N Carolina, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1351 / 1351
页数:1
相关论文
共 50 条
  • [31] 2D pixelated diamond detector for patient QA in advanced radiotherapy treatments
    Bartoli, A.
    Scaringella, M.
    Baldi, A.
    Greto, D.
    Scoccianti, S.
    Masi, L.
    Pallotta, S.
    Bruzzi, M.
    Talamonti, C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S459 - S460
  • [32] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [33] On the Influences of the Detector Size and Sampling Frequency On IMRT Verifications with 2D Arrays
    Poppe, B.
    Djouguela, A.
    Heidorn, S.
    Ruehmann, A.
    Willborn, K.
    Harder, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] COMMISSIONING AND EVALUATION OF DELTA4-A 3D DETECTOR FOR IMRT QA
    MacArtain, A. M.
    Fujak, E.
    Lutters, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 (11) : 641 - 641
  • [35] Curtailing patient-specific IMRT QA procedures from 2D dose error distribution
    Kurosu, Keita
    Sumida, Iori
    Mizuno, Hirokazu
    Otani, Yuki
    Oda, Michio
    Isohashi, Fumiaki
    Seo, Yuji
    Suzuki, Osamu
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (03) : 258 - 264
  • [36] Highly spatially resolved 2D plastic scintillation detector system for small field real-time QA
    Pittet, P.
    Ribouton, J.
    Jalade, P.
    Esteves, J.
    Blanc, F.
    Haefeli, G.
    Hopchev, P.
    Galvan, J.
    Lu, G.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S355 - S355
  • [37] The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification
    Collomb-Patton, V.
    Boher, P.
    Leroux, T.
    Fontbonne, J. -M.
    Vela, A.
    Batalla, A.
    MEDICAL PHYSICS, 2009, 36 (02) : 317 - 328
  • [39] Comparison of Institutional Radiochromic Film Data of Small Circular Collimators with a Sun Nuclear Edge Detector, IBA Stereotactic Field Diode (SFD), and the Mapcheck 2 QA Tool
    Hasson, B.
    Sullivan, P.
    Yeager, C.
    Hand, C.
    Murphy, W.
    MEDICAL PHYSICS, 2011, 38 (06) : 3619 - +
  • [40] Evaluation of a 2D detector array for patient-specific VMAT QA with different setups
    Boggula, Ramesh
    Birkner, Mattias
    Lohr, Frank
    Steil, Volker
    Wenz, Frederik
    Wertz, Hansjoerg
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7163 - 7177