Evaluation of the dynamic conformal arc therapy in comparison to intensity-modulated radiation therapy in prostate, brain, head-and-neck and spine tumors

被引:12
|
作者
Morales-Paliza, Manuel A. [1 ]
Coffey, Charles W. [1 ]
Ding, George X. [1 ]
机构
[1] Vanderbilt Univ, Dept Radiat Oncol, Med Ctr, Nashville, TN 37232 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2011年 / 12卷 / 02期
关键词
dynamic conformal arc therapy; intensity-modulated radiation therapy; dose validation; treatment time; external-beam radiation therapy; IMRT DOSE DISTRIBUTIONS; VOLUME HISTOGRAMS; CANCER; RADIOTHERAPY; TOXICITY; IMPACT; MOTION; DELIVERY;
D O I
10.1120/jacmp.v12i2.3197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity-modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three-dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose-volumetric histograms and in-house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360 arc for the brain lesion and several arcs including noncoplanar ones for the head-and-neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm-3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose-validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use.
引用
收藏
页码:5 / 19
页数:15
相关论文
共 50 条
  • [21] Spinal cord planning risk volumes for intensity-modulated radiation therapy of head-and-neck cancer
    Breen, SL
    Craig, T
    Bayley, A
    O'Sullivan, B
    Kim, J
    Jaffray, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (01): : 321 - 325
  • [22] Design and implementation of a head-and-neck phantom for system audit and verification of intensity-modulated radiation therapy
    Webster, Gareth J.
    Hardy, Mark J.
    Rowbottom, Carl G.
    Mackay, Ranald I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 46 - 56
  • [23] Intensity-modulated radiation therapy in the treatment of head and neck cancer
    Eisbruch, A
    NATURE CLINICAL PRACTICE ONCOLOGY, 2005, 2 (01): : 34 - 39
  • [24] Intensity-modulated radiation therapy in the treatment of head and neck cancer
    Avraham Eisbruch
    Nature Clinical Practice Oncology, 2005, 2 : 34 - 39
  • [25] Hypofractionated radiation therapy for head and neck cancers in the era of intensity-modulated radiation therapy
    Eom, Keun-Yong
    RADIATION ONCOLOGY JOURNAL, 2024, 42 (01): : 1 - 3
  • [26] A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer
    Fung-Kee-Fung, Simon D.
    Hackett, Rachel
    Hales, Lee
    Warren, Graham
    Singh, Anurag K.
    WORLD JOURNAL OF CLINICAL ONCOLOGY, 2012, 3 (04): : 57 - 62
  • [27] Comparison Between Fixed Gantry Angle Intensity Modulated Radiotherapy and Intensity Modulated Arc Therapy for Head-And-Neck Cancers
    Velasco, C.
    Penagaricano, J.
    Moros, E.
    Mihaylov, I.
    MEDICAL PHYSICS, 2009, 36 (06) : 2555 - +
  • [28] Dosimetric comparison of intensity-modulated radiation therapy (IMRT) and field-in-field (FIF) technique for head-and-neck cancer
    Thi Lan, Nguyen
    Dai Viet, Hoang
    Tai, Duong Thanh
    Chow, James C. L.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (02) : 153 - 158
  • [29] Importance of Radiation Oncologist Experience Among Patients With Head-and-Neck Cancer Treated With Intensity-Modulated Radiation Therapy
    Boero, Isabel J.
    Paravati, Anthony J.
    Xu, Beibei
    Cohen, Ezra E. W.
    Mell, Loren K.
    Quynh-Thu Le
    Murphy, James D.
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (07) : 684 - +
  • [30] Intensity-modulated radiation therapy and stereotactic body radiation therapy for head and neck tumors: Evidence-based medicine
    Lapierre, A.
    Martin, F.
    Lapeyre, M.
    CANCER RADIOTHERAPIE, 2014, 18 (5-6): : 468 - 472