Evaluation of the dynamic conformal arc therapy in comparison to intensity-modulated radiation therapy in prostate, brain, head-and-neck and spine tumors

被引:12
|
作者
Morales-Paliza, Manuel A. [1 ]
Coffey, Charles W. [1 ]
Ding, George X. [1 ]
机构
[1] Vanderbilt Univ, Dept Radiat Oncol, Med Ctr, Nashville, TN 37232 USA
来源
关键词
dynamic conformal arc therapy; intensity-modulated radiation therapy; dose validation; treatment time; external-beam radiation therapy; IMRT DOSE DISTRIBUTIONS; VOLUME HISTOGRAMS; CANCER; RADIOTHERAPY; TOXICITY; IMPACT; MOTION; DELIVERY;
D O I
10.1120/jacmp.v12i2.3197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity-modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three-dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose-volumetric histograms and in-house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360 arc for the brain lesion and several arcs including noncoplanar ones for the head-and-neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm-3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose-validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use.
引用
收藏
页码:5 / 19
页数:15
相关论文
共 50 条
  • [1] Evaluation of the Dynamic Conformal Arc Therapy as An Alternative to Intensity-Modulated Radiation Therapy in Prostate, Brain, Head-And-Neck, and Spine Tumors
    Paliza, M. Morales
    Lambert, H.
    Ding, G.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Evaluation of unified intensity-modulated arc therapy for the radiotherapy of head-and-neck cancer
    MacFarlane, Michael
    Hoover, Douglas A.
    Wong, Eugene
    Read, Nancy
    Palma, David
    Venkatesan, Varagur
    Hammond, Alex
    Battista, Jerry J.
    Chen, Jeff Z.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (02) : 331 - 336
  • [3] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [4] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study
    Rehman, Jalil Ur
    Isa, Muhammad
    Ahmad, Nisar
    Nasar, Gulfam
    Asghar, H. M. Noor Ul Huda Khan
    Gilani, Zaheer Abbas
    Chow, James C. L.
    Afzal, Muhammad
    Ibbott, Geoffrey S.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 129 - 135
  • [6] Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study
    Holt, Andrea
    Van Gestel, Dirk
    Arends, Mark P.
    Korevaar, Erik W.
    Schuring, Danny
    Kunze-Busch, Martina C.
    Louwe, Rob J. W.
    van Vliet-Vroegindeweij, Corine
    RADIATION ONCOLOGY, 2013, 8
  • [7] Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study
    Andrea Holt
    Dirk Van Gestel
    Mark P Arends
    Erik W Korevaar
    Danny Schuring
    Martina C Kunze-Busch
    Rob JW Louwe
    Corine van Vliet-Vroegindeweij
    Radiation Oncology, 8
  • [8] An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy
    Kim, S
    Akpati, HC
    Li, JG
    Liu, CR
    Amdur, RJ
    Palta, JR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05): : 1531 - 1539
  • [9] Choosing an intensity-modulated radiation therapy technique in the treatment of head-and-neck cancer
    Lee, Nancy
    Mechalakos, James
    Puri, Dev R.
    Hunt, Margie
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05): : 1299 - 1309
  • [10] The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy
    Hong, TS
    Tomé, WA
    Chappell, RJ
    Chinnaiyan, P
    Mehta, MP
    Harari, PM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 779 - 788