Dual-Element Intravascular Ultrasound Transducer for Tissue Harmonic Imaging and Frequency Compounding: Development and Imaging Performance Assessment

被引:20
|
作者
Lee, Junsu [1 ]
Chang, Jin Ho [1 ,2 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul 04107, South Korea
[2] Sogang Univ, Dept Biomed Engn, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
Intravascular ultrasound (IVUS) imaging; tissue harmonic imaging; frequency compounding; high-frequency ultrasound; dual-frequency IVUS transducers; VIRTUAL HISTOLOGY; PLAQUE; MHZ; RUPTURE; IVUS;
D O I
10.1109/TBME.2019.2901005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: For accurate diagnosis of atherosclerosis, the high spatial and contrast resolutions of intravascular ultrasound (IVUS) images are a key requirement. Increasing the center frequency of IVUS is a simple solution to meet this requirement. However, this leads to a reduction in imaging depth due to the frequency-dependent attenuation of ultrasound. Here, we report a recently developed dual-element IVUS transducer for tissue harmonic imaging (THI) and frequency compounding to increase the spatial and contrast resolutions of IVUS images, while maintaining the imaging depth to assess the overall morphological change of blood vessels. Methods: One 35-MHz element is used for producing general IVUS images and the other 70-MHz element is for receiving the second harmonic signals induced by the 35-MHz ultrasound. The fundamental and second harmonic signals can also be used for frequency compound imaging to further improve contrast resolution. The spatial and contrast resolutions achieved by the developed transducer were evaluated through wire and tissue-mimicking phantom imaging tests. Additionally, the images of a stent deployed in a tissue-mimicking phantom and an excised pig artery were acquired to assess clinical usefulness of the transducer. Results: The results demonstrated that the developed IVUS transducer enables us to simultaneously examine the overall morphological change of blood vessels by the 35-MHz ultrasound images and the near vessel layers such as the intima, the media, and the adventitia by either THI or compound images with high spatial and contrast resolutions. In addition, the developed transducer facilitates the simultaneous acquisition of 35- and 70-MHz fundamental images when needed. Conclusion: The developed dual-element IVUS transducer makes it possible to fully realize the potential benefits of IVUS in the diagnosis of atherosclerosis.
引用
收藏
页码:3146 / 3155
页数:10
相关论文
共 50 条
  • [31] A novel dual-frequency imaging method for intravascular ultrasound applications
    Qiu, Weibao
    Chen, Yan
    Wong, Chi-Man
    Liu, Baoqiang
    Dai, Jiyan
    Zheng, Hairong
    [J]. ULTRASONICS, 2015, 57 : 31 - 35
  • [32] Ultrasound Harmonic Imaging with Reducing Speckle Noise by Spatial-Frequency Compounding Approach
    Guo, Wei
    Wang, Yuanyuan
    Yu, Jinhua
    [J]. SEVENTH INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2015), 2015, 9817
  • [33] Design and Fabrication of a Novel Dual-Frequency Confocal Ultrasound Transducer for Microvessels Super-Harmonic Imaging
    Deng, Xinqi
    Xu, Tingnian
    Huang, Guoming
    Li, Qinghao
    Luo, Liyang
    Zhao, Yue
    Wu, Zhengjie
    Ou-Yang, Jun
    Yang, Xiaofei
    Xie, Mingxing
    Zhu, Benpeng
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1272 - 1277
  • [34] Ultrasound Harmonic Imaging with Reducing Speckle Noise by an Interlaced Iterative Frequency Compounding Approach
    Guo, Wei
    Wang, Yuanyuan
    Yu, Jinhua
    [J]. 2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 34 - 39
  • [35] DEVELOPMENT OF A 12 ELEMENT ANNULAR ARRAY TRANSDUCER FOR REALTIME ULTRASOUND IMAGING
    FOSTER, FS
    LARSON, JD
    MASON, MK
    SHOUP, TS
    NELSON, G
    YOSHIDA, H
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07): : 649 - 659
  • [36] Dual-frequency intravascular ultrasound imaging: A novel approach to plaque vulnerability
    Hashimoto, G
    Hiro, T
    Fujii, T
    Okamura, T
    Yamada, J
    Fukumoto, Y
    Kanou, H
    Matsuzaki, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 120A - 121A
  • [37] Dual-frequency IVUS array for contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Huang, Wenbin
    Jiang, Xiaoning
    Martin, K. Heath
    Dayton, Paul A.
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [38] An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Ma, Jianguo
    Jiang, Xiaoning
    Martin, Karl Heath
    Dayton, Paul A.
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2104 - 2107
  • [39] Interleaved Array Transducer with Polarization Inversion Technique to Implement Ultrasound Tissue Harmonic Imaging
    Park, Chan Yuk
    Sung, Jin Ho
    Jeong, Eun Young
    Lee, Hee Su
    Jeong, Jong Seob
    [J]. SENSORS, 2020, 20 (14) : 1 - 14
  • [40] Tissue Harmonic Compounded Imaging with Dual-Frequency Chirp Excitation
    Lin, Chin-Hsiang
    Shen, Che-Chou
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 370 - 373