Analytical evaluation of the Tosoh HLC-723 G7 automated HPLC analyzer for hemoglobin A2 and F determination

被引:13
|
作者
Paleari, R
Cannata, M
Leto, F
Maggio, A
Demartis, FR
Desogus, MF
Galanello, R
Mosca, A
机构
[1] Univ Milan, Dipartimento Sci & Tecnol Biomed, I-20090 Milan, Italy
[2] Unita Operat Ematol II Con Talassemia, I-90146 Palermo, Italy
[3] Univ Cagliari, Osped Microcitem ASL8, Lab Ematol, I-09121 Cagliari, Italy
关键词
Hb A(2); Hb F; thalassemia; HPLC; Tosoh HLC-723 G7; standardization;
D O I
10.1016/j.clinbiochem.2004.10.017
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The analytical performance of a new automated HPLC system (Tosoh HLV-723 G7) for Hb A(2) and Hb F quantification in blood was studied. Design and methods: Hb A(2) and Hb F measurements were studied for imprecision, linearity, carry-over, interferences and sample concentration effect. Method comparison study was performed with the Bio-Rad Variant II HPLC system. Hb F results were also compared with those obtained by the alkaline denaturation test. The detection of some common Hb variants was also studied. Results: Hb A(2) within-run and between-run CVs were found between 0.8-2.2% and 2.9-7.2%, respectively, while CVs for Hb F were up to 10.0% in normal and between 1.9-5.3% at more clinically relevant Hb F concentrations (>1.5%). Comparison study with Bio-Rad Variant II for Hb A(2) determination showed good correlation but highlighted calibration differences. The following results were obtained in two different laboratories: y = 1.163x - 0.52, r = 0.9918, n = 144 (Lab A); y = 1.060x - 0.40, r = 0.9920, n = 93 (Lab B). With regard to the determination of Hb F, the measurements performed by the tested method was found to correlate well with the alkaline denaturation test (y = 1.0138x - 0.36, r = 0.9842, n = 20) and with the Variant II HPLC system (y = 0.812x + 0.52, r = 0.9835, n = 110). An excellent linearity (r = 0.999) was found for both Hb A(2) and Hb F in the range 0.8-19%. Hb S, Hb C and Hb D can be presumptively identified by the assigned retention time windows. Conclusion: The new analyzer Tosoh HLV-723 G7 was found to be a reliable method for Hb A(2) and Hb F quantification and for the presumptive identification of some common Hb variants. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 25 条
  • [21] EVALUATION OF AN AUTOMATED HEMOGLOBIN ANALYZER FOR THE QUANTITATION OF HEMOGLOBIN-A2 AND HEMAGLOBIN-F AND QUALITATIVE-ANALYSIS OF HEMOGLOBIN-VARIANTS
    MODI, G
    FERNANDES, B
    TANG, E
    ABBOTT, D
    BLOOD, 1993, 82 (10) : A472 - A472
  • [22] Evaluation of a dual hemoglobin A2/A1c quantitation kit on the bio-rad variant II automated hemoglobin analyzer
    Lafferty, JD
    McFarlane, AG
    Chui, DHK
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2002, 126 (12) : 1494 - 1500
  • [23] Analytical evaluation of hemoglobin A1c dual kit assay on Bio-Rad Variant II:: an automated HPLC hemoglobin analyzer for the management of diabetic patients
    Moridani, MY
    Verjee, Z
    Allen, LC
    CLINICAL BIOCHEMISTRY, 2003, 36 (04) : 317 - 320
  • [24] Evaluation of the Analytical Performance of the Fully Automated Gene Analyzer μTASWako g1 for the Detection of SARS-CoV-2
    Toda, Hirofumi
    Tanaka, Yuji
    Yamade, Kenji
    Tsujimoto, Mayu
    Takada, Haruka
    Ueno, Minoru
    Tsuda, Yoshihiro
    Kishino, Yoshizumi
    Kubo, Shuichi
    Kamisako, Toshinori
    Yoshida, Koichiro
    CLINICAL LABORATORY, 2023, 69 (02) : 425 - 429
  • [25] A comparative evaluation of the analytical performances of premier resolution-high-performance liquid chromatography (PR-HPLC) with capillary zone electrophoresis (CZE) assays for the detection of hemoglobin variants and the quantitation of HbA0, A2, E, and F
    Laksap, Sirikwan
    Suanboon, Suphisara
    Punyamung, Manoo
    Ruengdit, Chedtapak
    Pornprasert, Sakorn
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1383 - 1392