Copper-Selective PVC Membrane Sensor

被引:0
|
作者
Ganjali, Mohammad Reza [1 ]
Ghafarloo, Ali [1 ]
Faridbod, Farnoush [1 ]
Norouzi, Parviz [1 ]
机构
[1] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
来源
关键词
Potentiometry; sensor; copper; ion selective electrode; PVC membrane; CARBON-PASTE ELECTRODE; NANOPOROUS SILICA-GEL; LANTHANIDE RECOGNITION; POTENTIOMETRIC DETERMINATION; SEDIMENT SAMPLES; IONS; MICROSENSOR; HYDROCHLORIDE; CONSTRUCTION; FLUORIDE;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Spectroscopic study in acetonitrile solution shows a selective interaction between 1-(2-hydroxybenzylidene) thiosemicarbazide (L) and copper cation in comparison with other inorganic metal ions. Thus, L was then used as a good sensing material in copper selective PVC membrane sensor. The proposed potentiometric sensor showed a stable potential response to Cu2+ ions with Nernstian slope of 28.6 +/- 0.4 mV decade(-1) over a wide linear concentration range of 1.0x10(-5)-1x10(-1) mol L-1. The sensor was found to have a short response time of about 25 s and have an acceptable life time. Application of the proposed sensor in analysis of copper content of some water samples showed good results.
引用
收藏
页码:3706 / 3716
页数:11
相关论文
共 50 条
  • [31] A novel silver(I)-selective PVC membrane sensor and its potentiometric applications
    Isildak, Omer
    Deligonul, Nihal
    Ozbek, Oguz
    TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1149 - 1158
  • [32] Manganese (II) selective PVC based membrane sensor using a Schiff base
    Gupta, Vinod K.
    Jain, Ajay K.
    Maheshwari, Gaurav
    TALANTA, 2007, 72 (01) : 49 - 53
  • [33] Ho3+ Ion Selective Microelectrode: An Asymmetric PVC Membrane Sensor
    Faridbod, Farnoush
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (12): : 1679 - 1690
  • [34] Mercury ion selective light addressable potentiometric sensor based on PVC membrane
    Li Y.
    Zhang Z.-N.
    Cai W.
    Gao X.-M.
    Wang P.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (06): : 1231 - 1236
  • [35] COPPER-SELECTIVE ION-EXCHANGE RESIN WITH IMPROVED IRON REJECTION
    GRINSTEAD, RR
    JOURNAL OF METALS, 1979, 31 (03): : 13 - 16
  • [36] Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper
    Gupta, VK
    Prasad, R
    Kumar, A
    TALANTA, 2003, 60 (01) : 149 - 160
  • [37] COPPER-SELECTIVE ELECTRODES BASED ON TYPE-BETA-VANADIUM OXIDE BRONZES
    VOLKOV, VL
    MANAKOVA, LI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (05): : 594 - 596
  • [38] SIMPLE POTENTIOMETRIC METHOD FOR DETERMINATION OF REDUCING SUBSTANCES IN URINE WITH A COPPER-SELECTIVE ELECTRODE
    NIKOLELIS, DP
    PAPASTATHOPOULOS, DS
    HADJIIOANNOU, TP
    ANALYTICA CHIMICA ACTA, 1978, 98 (02) : 227 - 232
  • [39] COPPER-SELECTIVE AND CADMIUM-SELECTIVE ELECTRODES AS INDICATOR ELECTRODES IN TITRATION OF VANADYL IONS WITH EDTA
    NAPOLI, A
    MASCINI, M
    ANALYTICA CHIMICA ACTA, 1977, 89 (01) : 209 - 211
  • [40] COPPER-SELECTIVE ION-EXCHANGE RESIN WITH IMPROVED IRON REJECTION.
    Grinstead, Robert R.
    1979, 31 (03): : 13 - 16