A novel zinc finger protein-based amperometric biosensor for miRNA determination

被引:25
|
作者
Povedano, Eloy [1 ]
Ruiz-Valdepenas Montiel, Victor [1 ]
Gamella, Maria [1 ]
Serafin, Veronica [1 ]
Pedrero, Maria [1 ]
Moranova, Ludmila [2 ]
Bartosik, Martin [2 ]
Montoya, Juan Jose [3 ,4 ]
Yanez-Sedeno, Paloma [1 ]
Campuzano, Susana [1 ]
Pingarron, Jose M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, Madrid 28040, Spain
[2] Masaryk Mem Canc Inst, Reg Ctr Appl Mol Oncol RECAMO, Zluty Kopec 7, Brno 65653, Czech Republic
[3] Univ Complutense Madrid, Cannan Res & Investment, Madrid 28040, Spain
[4] Univ Complutense Madrid, Fac Med, Madrid 28040, Spain
关键词
Zinc finger protein; Screen-printed electrodes; miR-21; DNA METHYLATION LEVELS; CPG-BINDING PROTEIN; ELECTROCHEMICAL DETECTION; MULTIPLEXED DETECTION; SIGNAL AMPLIFICATION; MICRORNA EXPRESSION; BREAST-CANCER; HYBRIDIZATION; IMMUNOSENSOR; BIOMARKERS;
D O I
10.1007/s00216-019-02219-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports a simple electrochemical strategy for the determination of microRNAs (miRNAs) using a commercial His-Tag-Zinc finger protein (His-Tag-ZFP) that binds preferably (but non-sequence specifically) RNA hybrids over ssRNAs, ssDNAs, and dsDNAs. The strategy involves the use of magnetic beads (His-Tag-Isolation-MBs) as solid support to capture the conjugate formed in homogenous solution between His-Tag-ZFP and the dsRNA homohybrid formed between the target miRNA (miR-21 selected as a model) and a biotinylated synthetic complementary RNA detector probe (b-RNA-Dp) further conjugated with a streptavidin-horseradish peroxidase (Strep-HRP) conjugate. The electrochemical detection is carried out by amperometry at disposable screen-printed carbon electrodes (SPCEs) (- 0.20 V vs Ag pseudo-reference electrode) upon magnetic capture of the resultant magnetic bioconjugates and H(2)O(2)addition in the presence of hydroquinone (HQ). The as-prepared biosensor exhibits a dynamic concentration range from 3.0 to 100 nM and a detection limit (LOD) of 0.91 nM for miR-21 in just similar to 2 h. An acceptable discrimination was achieved between the target miRNA and other non-target nucleic acids (ssDNA, dsDNA, ssRNA, DNA-RNA, miR-122, miR-205, and single central- or terminal-base mismatched sequences). The biosensor was applied to the analysis of miR-21 from total RNA (RNA(t)) extracted from epithelial non-tumorigenic and adenocarcinoma breast cells without target amplification, pre-concentration, or reverse transcription steps. The versatility of the methodology due to the ZFP's non-sequence-specific binding behavior makes it easily extendable to determine any target RNA only by modifying the biotinylated detector probe.
引用
收藏
页码:5031 / 5041
页数:11
相关论文
共 50 条
  • [41] Nanoparticle based Amperometric Biosensor for the Quantitative Determination of Cholesterol in Human Blood
    Al Jarallah, Nasser
    Al Baradie, Raid
    Aljamal, Mohmmed
    Bose, Anandh
    Al Anazi, Hamed
    Alatram, Abdulrahman
    Al Aboody, Mohammed
    Algohary, Ayman
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2014, 7 (05):
  • [42] Investigation of a multienzyme based amperometric biosensor for determination of sucrose in fruit juices
    Majer-Baranyi, Krisztina
    Adanyi, Nora
    Varadi, Maria
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 228 (01) : 139 - 144
  • [43] Amperometric cytochrome c3-based biosensor for chromate determination
    Michel, C
    Battaglia-Brunet, F
    Minh, CT
    Bruschi, M
    Ignatiadis, I
    BIOSENSORS & BIOELECTRONICS, 2003, 19 (04): : 345 - 352
  • [44] Luminescencence Determination of Ecotoxicants in Protein-Based Media
    Plotnikova, O. A.
    Mel'nikov, A. G.
    Mel'nikov, G. V.
    Kovalenko, A. V.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B, 2017, 11 (04) : 666 - 672
  • [45] Luminescencence determination of ecotoxicants in protein-based media
    O. A. Plotnikova
    A. G. Mel’nikov
    G. V. Mel’nikov
    A. V. Kovalenko
    Russian Journal of Physical Chemistry B, 2017, 11 : 666 - 672
  • [46] A Bacteriophage Protein-Based Impedimetric Electrochemical Biosensor for the Detection of Campylobacter jejuni
    Suganthan, Baviththira
    Rogers, Ashley M.
    Crippen, Clay S.
    Asadi, Hamid
    Zolti, Or
    Szymanski, Christine M.
    Ramasamy, Ramaraja P.
    BIOSENSORS-BASEL, 2024, 14 (08):
  • [47] A novel amperometric biosensor for determination of hydrogen peroxide based on nafion and polythionine as well as gold nanoparticles and gelatin as matrixes
    Zhu, Q
    Yuan, R
    Chai, YQ
    Zhuo, Y
    Zhang, Y
    Li, XL
    Wang, N
    ANALYTICAL LETTERS, 2006, 39 (03) : 483 - 494
  • [48] Development and Characterization of a Fluorescent Protein-Based Biosensor for the Detection of Extracellular ATP
    Conley, Jason M.
    Radhakrishnan, Saranya
    Valentino, Stephen A.
    Tantama, Mathew C.
    FASEB JOURNAL, 2017, 31
  • [49] A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite
    O. V. Soldatkina
    O. O. Soldatkin
    B. Ozansoy Kasap
    D. Yu. Kucherenko
    I. S. Kucherenko
    B. Akata Kurc
    S. V. Dzyadevych
    Nanoscale Research Letters, 2017, 12
  • [50] A novel amperometric biosensor based on ZnO:Co nanoclusters for biosensing glucose
    Zhao, Z. W.
    Chen, X. J.
    Tay, B. K.
    Chen, J. S.
    Han, Z. J.
    Khor, Khiam Aik
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (01): : 135 - 139