Precise measurement of 228Ra/226Ra for 226Ra determination employing total integration and simultaneous 228Th correction by multicollector ICP-MS using multiple ion counters

被引:7
|
作者
Makishima, Akio [1 ]
Chekol, Takele A. [1 ]
Nakamura, Eizo [1 ]
机构
[1] Okayama Univ Misasa, Inst Study Earths Interior, Pheasant Mem Lab Geochem & Cosmochem PML, Tottori 6820193, Japan
关键词
D O I
10.1039/b807431c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A precise method of measuring Ra-228/Ra-226 for Ra-226 determination used in U-series disequilibrium studies has been developed using the total integration method with simultaneous 228Th isobaric interference correction by multicollector ICP- MS with multiple ion counters (MIC). A sample solution of 0.2 ml was separately taken into a test tube, and all Ra-226(+) and Ra-228(+) signals as well as Th-229(+) and (ThO+)-Th-228-O-16 from beginning to end were integrated simultaneously using four channeltrons, IC1, IC3, IC4 and IC5, respectively. Gains between IC1 and IC3 and the mass discrimination factor for Ra-228/ (226) Ra determination were canceled out by measurement of a Ra spike solution with an accurately known Ra isotope ratio determined by TIMS, with which samples were bracketed. The isobaric interferences of Th-228(+) were simultaneously corrected from the signal of (ThO+)-Th-228-O-16 and the oxide forming ratio of Th-228, which was separately determined by simultaneous measurements of Th-229(+) and 2(29)Th(16)O(+) by IC3 and IC5. The gains between IC3 and IC5 for the Th correction were also canceled out. The ion yield of Ra in MIC- ICP- MS was similar to 1.5%. The intermediate precision using 6.6, 3.3, 1.7, 0.83 and 0.41 fg of Ra-226 with Ra-228/Ra-226 similar to 5 was 0.33, 0.93, 0.76, 1.6 and 1.5%, respectively. The Ra-228/Ra-226 ratio showed no systematic change dependent on Th-228/Ra-228 up to 0.25, indicating the validity of the Th-228 correction. At similar amounts of Ra, our method gives intermediate precision values similar to or better than previous MC-ICP-MS and TIMS studies. The precision of the method was verified using another Ra spike with Ra-228/ Ra-226 = similar to 1 determined by TIMS. The analytical performance of the method was further investigated using the silicate samples JB-2 and JB-3 basalts issued by GSJ.
引用
收藏
页码:1102 / 1107
页数:6
相关论文
共 50 条
  • [31] Distribution coefficients and concentration factors of 226Ra and 228Th in the Greek marine environment
    Trabidou, G
    Florou, H
    Kritidis, P
    Chaloulou, C
    Lykomitrou, C
    Natural Radiation Environment VII, 2005, 7 : 1167 - 1176
  • [32] Measurement of 228Ra/226Ra activity ratio in river water using Mn-impregnated acrylic fiber
    Nakano-Ohta, T
    Saito, T
    Sato, J
    BUNSEKI KAGAKU, 2005, 54 (12) : 1219 - 1222
  • [33] Non-destructive determination of 224Ra, 226Ra and 228Ra concentrations in drinking water by gamma spectroscopy
    Parekh, P
    Haines, D
    Bari, A
    Torres, M
    HEALTH PHYSICS, 2003, 85 (05): : 613 - 620
  • [34] Measurement of 224Ra, 226Ra and 228Ra in seawater using Mn-fiber adsorption-γ spectrum method
    Liu Guangshan1
    Huang Yipu1
    Chen Xinbao1 (1. Department of Oceanography
    Acta Oceanologica Sinica, 2000, (02) : 19 - 27
  • [36] Validation of a newly adopted chemical method for determination of 226Ra and 228Ra activities in water and shrimp samples
    Sahin, Mihriban
    Dikmen, Hasan
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 334 (3) : 2163 - 2170
  • [37] MEASUREMENT OF 226RA AND 228RA IN WATER BY GAMMA-RAY COUNTING AFTER PRECONCENTRATION ON ION-EXCHANGE RESIN
    CLIFFORD, DA
    HIGGINS, EA
    HEALTH PHYSICS, 1992, 62 (05): : 413 - 421
  • [38] 226Ra/238U and 228Th/228Ra disequilibrium as weathering indices in beach sand sediments associated with granitoids from Cyclades. Greece
    Papadopoulos, A.
    APPLIED GEOCHEMISTRY, 2019, 100 : 223 - 233
  • [39] Using 226Ra/228Ra disequilibrium to determine the residence half-lives of radium in vegetation compartments
    Baeza, A
    Barandica, J
    Paniagua, JM
    Rufo, M
    Sterling, A
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1999, 43 (03) : 291 - 304
  • [40] On the direct measurement of 226Ra and 228Ra using 3M Empore™ RAD disk by liquid scintillation spectrometry
    J. Fons-Castells
    M. Vasile
    H. Loots
    M. Bruggeman
    M. Llauradó
    F. Verrezen