Robustness of distance relay with MHO characteristic against fault resistance

被引:0
|
作者
Jamali, S [1 ]
Shateri, H [1 ]
机构
[1] Iran Univ Sci & Technol, Tehran, Iran
关键词
arcing faults; boundary fault resistance; distance protection; fault resistance; robustness criterion;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper discusses the maximum earth fault resistance, which can be tolerated by a distance relay with Mho characteristic. This is defined as the boundary fault resistance the relay can discriminate between in-zone and out-of-zone faults. The robustness criterion is defined on the basis of the boundary fault resistance. In order to achieve this, the related equations are first derived and then the boundary fault resistance curve is presented. The simulation results for a typical transmission system shows the effectiveness of the proposed robustness criterion for distance relays settings.
引用
收藏
页码:679 / 683
页数:5
相关论文
共 50 条
  • [41] DIRECTIONAL CHARACTERISTICS OF DISTANCE RELAY MHO ELEMENTS - 1. A NEW METHOD OF ANALYSIS.
    Marttila, R.J.
    Proceedings of the Annual Reliability and Maintainability Symposium, 1980,
  • [42] An Exploration of the D-FACTS Influence in the Mho Ground Distance Elements in Presence of Fault Resistance and Parallel Lines Mutual Coupling
    Beleed, Hussain
    Johnson, Brian K.
    Hess, Herbert L.
    2019 51ST NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2019,
  • [43] Advanced method for testing of distance relay operating characteristic
    Kezunovic, M
    Xia, YQ
    Guo, Y
    Fromen, CW
    Sevcik, DR
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 149 - 157
  • [44] Fault component impedance relay with double circular characteristic
    Huang, Shaofeng
    Liu, Qiankuan
    Liu, Huanzhang
    Yang, Qixun
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3712 - 3718
  • [45] Measuring of Fault Distance Using the Fault Locator Function of Protection Relay
    Kotulla, Michal
    Vrzala, Matous
    Gono, Radomir
    PROCEEDINGS OF THE 2019 20TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2019, : 249 - 253
  • [46] Fault component distance relay with changeable circle characteristics
    Liu, Qiankuan
    Liu, Huanzhang
    Huang, Shaofeng
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (12): : 77 - 83
  • [47] A novel analysis of offset mho characteristic of memory-polarized and cross-polarized distance functions
    Sorrentino, Elmer
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 158 : 219 - 227
  • [48] A power amplifier system for testing of distance relay operating characteristic
    Marcal, Rui
    Rodrigues, Ricardo
    Fortunato, Carlos
    Martins, Luis Sousa
    Pires, Vitor Fernao
    2006 12TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2006, : 527 - +
  • [49] Effects of SMES Equipped UPFC on Distance Relay Tripping Characteristic
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 883 - 889
  • [50] Effects of SMES equipped SSSC on distance relay tripping characteristic
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1002 - 1007