Sensitivity of secondary Monte Carlo Dose Calculation with 4 Hz log files for MLC Errors for Quality Assurance of VMAT Plans

被引:0
|
作者
Szeverinski, P. [1 ,3 ]
Kowatsch, M. [1 ]
Meinschad, M. [1 ]
Kuenzler, T. [1 ]
Clemens, P. [2 ]
De Vries, A. [2 ]
机构
[1] Lehrkrankenhaus Feldkirch, Inst Med Phys, Feldkirch, Austria
[2] Lehrkrankenhaus Feldkirch, Abt Radioonkol, Feldkirch, Austria
[3] Private Univ Furstentum Liechtenstein, Triesen, Liechtenstein
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
P16-2
引用
收藏
页码:S218 / S219
页数:2
相关论文
共 30 条
  • [21] Study on the Sensitivity of Gamma-Index Evaluation Methods to Positioning Errors of High-Definition MLC of True Beam STx in VMAT Quality Assurance for SBRT
    Hwang, S.
    Ye, S.
    Park, J.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S858 - S859
  • [22] Dosimetric Quality Assurance of Plans Calculated with the Electron Monte Carlo Algorithm with Dose Measurement Using a Multiple Diode-Array Detector
    Ahmad, S.
    Kendall, E.
    Ali, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E249 - E249
  • [23] Clinical implementation of a PRIMO Monte Carlo-based dose verification and quality assurance model for stereotactic body radiotherapy (SBRT) treatment plans of the lung
    Sarin, B.
    Bindhu, B.
    Saju, B.
    Raghukumar, P.
    Nair, R. K.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (03): : 563 - 570
  • [24] Automated Monte-Carlo re-calculation of proton therapy plans using GEANT4/GATE: implementation and comparison to plan-specific quality assurance measurements
    Aitkenhead, Adam H.
    Sitch, Peter
    Richardson, Jenny C.
    Winterhalter, Carla
    Patel, Imran
    Mackay, Ranald, I
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1114):
  • [25] Development of a flattening filter free multiple source model for use as an independent, Monte Carlo, dose calculation, quality assurance tool for clinical trials
    Faught, Austin M.
    Davidson, Scott. E.
    Popple, Richard
    Kry, Stephen F.
    Etzel, Carol
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2017, 44 (09) : 4952 - 4960
  • [26] Monte Carlo Based VMAT Dose Re-Optimization for Patient Specific Quality Assurance and Failed Plan Recovery Using Re-Weighted Aperture MUs
    Folkerts, M.
    Modiri, A.
    Ungun, B.
    Jia, X.
    Jiang, S.
    Sawant, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3192 - 3192
  • [27] Is the Standard IMRT/VMAT QA Good Enough? Investigating Log File Monte Carlo-Based Quality Assurance (LF-MC QA) as An Alternative Treatment Planning/Delivery QA Technique
    Stanhope, C.
    Alber, M.
    Sohn, M.
    Drake, D.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E245 - E245
  • [28] Developing a Workflow Using Supercomputer Accelerated Monte Carlo Simulation Based On Machine Log-Files for Patient Specific Quality Assurance of the Mevion S250i Proton Therapy System
    Chiang, B.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [29] The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance
    Maraghechi, Borna
    Davis, Jack
    Mitchell, Nicholas
    Shah, Meeral
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 66 - 77
  • [30] Validation of Log Based Fast 3D-Dose Verification System (LBF3D-DVS) Using Simplified Monte-Carlo (SMC) Method for Daily Patient Specific Quality Assurance
    Mizutani, S.
    Hotta, K.
    Baba, H.
    Tanizaki, N.
    Yamaguchi, T.
    Akimoto, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E589 - E589