Intercomparison of TL dosimetry (DIMOND programme)

被引:0
|
作者
Kottou, S [1 ]
Papadimitriou, D [1 ]
机构
[1] Univ Athens, Sch Med, Dept Med Phys, Athens, Greece
关键词
D O I
10.1093/oxfordjournals.rpd.a006455
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During DIMOND CA, a thermoluminescence dosimetry intercomparison has been performed, in order to ensure that all participants measure the same dose. After the calibrating and annealing procedures, 50 TLD pellets (in groups of five) of each participating country were sent to the coordinator to be irradiated with 'unknown' radiations (blind test). The irradiation conditions (8 different set-ups. one for each group of pellets per participant) were (i) one gamma irradiation (Co-60), at air kerma in the range of 0.3 to 50.0 mGy, (ii) seven X ray irradiations, at air kerma in the range of 0.3 to 50.0 mGy, with tube potential in the range of 40 to 150 kV and a variety of filter combinations. Ten pellets (two groups) were used for background and transport dose evaluation. After measuring the TLDs, the participants sent the results to the coordinator for intercomparison. Irradiating set-up conditions, evaluated doses, as well as comparison of mean values with the 'true' nominal doses are presented and discussed.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 50 条
  • [21] Uk laboratory intercomparison on internal dosimetry
    Speed, J
    Birchall, A
    Bull, R
    Cockerill, R
    Jarvis, NS
    Marsh, JW
    Peace, MS
    Roberts, G
    Scarlett, C
    Spencer, D
    Stewart, P
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (03) : 221 - 229
  • [22] A dosimetry intercomparison phantom for intraoperative radiotherapy
    Armoogum, Kris
    Watson, Colin
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (02): : 120 - 127
  • [23] Dosimetry intercomparison under reference conditions
    Adolfsson, E.
    Fransson, K. Westerberg
    Larsson, P.
    Eriksson, J.
    Dellow, E.
    Olsson, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1454 - S1455
  • [24] NUCLEAR ACCIDENT DOSIMETRY INTERCOMPARISON STUDIES
    SIMS, CS
    HEALTH PHYSICS, 1989, 57 (03): : 439 - 448
  • [25] BIPM NEUTRON-DOSIMETRY INTERCOMPARISON
    HUYNH, VD
    METROLOGIA, 1992, 29 (04) : 295 - 299
  • [26] AN INTERCOMPARISON OF NEUTRON FIELD DOSIMETRY SYSTEMS
    THOMAS, DJ
    WAKER, AJ
    HUNT, JB
    BARDELL, AG
    MORE, BR
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 219 - 222
  • [27] INTERCOMPARISON OF CRITICALITY ACCIDENT DOSIMETRY SYSTEMS
    GREENE, RT
    SWAJA, RE
    HEALTH PHYSICS, 1983, 45 (01): : 191 - 191
  • [28] QUALITY AUDIT OF MEGAVOLTAGE RADIOTHERAPY UNITS - INTERCOMPARISON OF DOSE AT A REFERENCE POINT USING A MAILED TL-DOSIMETRY SYSTEM
    DAVIS, B
    FAESSLER, P
    RADIOTHERAPY AND ONCOLOGY, 1993, 28 (01) : 79 - 81
  • [29] SURVEY OF RADIOTHERAPY DOSIMETRY CONSISTENCY IN THE UK - IPSM RADIOTHERAPY DOSIMETRY INTERCOMPARISON
    THWAITES, DI
    WILLIAMS, JR
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 742 - 743
  • [30] MAGNESIUM BORATE IN TL DOSIMETRY
    PROKIC, M
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 393 - 396