Intercomparison of TL dosimetry (DIMOND programme)

被引:0
|
作者
Kottou, S [1 ]
Papadimitriou, D [1 ]
机构
[1] Univ Athens, Sch Med, Dept Med Phys, Athens, Greece
关键词
D O I
10.1093/oxfordjournals.rpd.a006455
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During DIMOND CA, a thermoluminescence dosimetry intercomparison has been performed, in order to ensure that all participants measure the same dose. After the calibrating and annealing procedures, 50 TLD pellets (in groups of five) of each participating country were sent to the coordinator to be irradiated with 'unknown' radiations (blind test). The irradiation conditions (8 different set-ups. one for each group of pellets per participant) were (i) one gamma irradiation (Co-60), at air kerma in the range of 0.3 to 50.0 mGy, (ii) seven X ray irradiations, at air kerma in the range of 0.3 to 50.0 mGy, with tube potential in the range of 40 to 150 kV and a variety of filter combinations. Ten pellets (two groups) were used for background and transport dose evaluation. After measuring the TLDs, the participants sent the results to the coordinator for intercomparison. Irradiating set-up conditions, evaluated doses, as well as comparison of mean values with the 'true' nominal doses are presented and discussed.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 50 条
  • [1] Intercomparison of TL dosimetry (DIMOND programme)
    Kottou, S
    Papadimitriou, D
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 125 - 128
  • [2] Argentine intercomparison programme for personal dosimetry
    Gregori, B. N.
    Papadpulos, S. B.
    Saravi, M.
    Kunst, J. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 98 - 100
  • [3] TL dosimetry application for accelerator X-ray beam intercomparison
    Andric, S
    Prokic, M
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1997, 13 : 80 - 82
  • [4] Intercomparison of dosimetry systems based on CaF2:Mn TL detectors
    Zorko, B.
    Miljanic, S.
    Vekic, B.
    Stuhec, M.
    Gobec, S.
    Ranogajec-Komor, M.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 300 - 305
  • [5] Proton dosimetry intercomparison
    Vatnitsky, S
    Siebers, J
    Miller, D
    Moyers, M
    Schaefer, M
    Jones, D
    Vynckier, S
    Hayakawa, Y
    Delacroix, S
    Isacsson, U
    Medin, J
    Kacperek, A
    Lomax, A
    Coray, A
    Kluge, H
    Heese, J
    Verhey, L
    Daftari, I
    Gall, K
    Lam, G
    Beck, T
    Hartmann, G
    RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) : 169 - 177
  • [6] PERSONNEL DOSIMETRY INTERCOMPARISON STUDIES
    GILLEY, LW
    DICKSON, HW
    HEALTH PHYSICS, 1978, 35 (06): : 910 - 910
  • [7] An international neutron dosimetry intercomparison
    Maughan, RL
    Yudelev, M
    Brossard, SD
    Horton, JL
    Vynckier, S
    MEDICAL PHYSICS, 1995, 22 (12) : 2103 - 2104
  • [8] NEUTRON DOSIMETRY INTERCOMPARISON STUDIES
    SIMS, CS
    DICKSON, HW
    DICKSON, HW
    RADIATION PROTECTION DOSIMETRY, 1985, 10 (1-4) : 331 - 340
  • [9] An international neutron dosimetry intercomparison
    Gershenson Radiation Oncology Center, Harper Hospital, Wayne State University, 3990 John R, Detroit, MI 48201, United States
    MED. PHYS., 12 (2103-2104):
  • [10] REPORT ON THE BERKELEY DOSIMETRY INTERCOMPARISON
    LYMAN, JT
    BLATTMAN, H
    FESSENDEN, P
    LAM, KY
    MCDONALD, JC
    SMITH, AR
    VERHEY, L
    MEDICAL PHYSICS, 1980, 7 (04) : 425 - 425