Frictional Behavior of Cochlear Electrode Array Is Dictated by Insertion Speed and Impacts Insertion Force

被引:7
|
作者
Dohr, Dana [1 ]
Fiedler, Nicklas [2 ]
Schmidt, Wolfram [2 ]
Grabow, Niels [2 ]
Mlynski, Robert [1 ]
Schraven, Sebastian P. [1 ]
机构
[1] Rostock Univ, Med Ctr, Dept Otorhinolaryngol Head & Neck Surg Otto Korne, Doberaner Str 137-139, D-18057 Rostock, Germany
[2] Rostock Univ, Med Ctr, Inst Biomed Engn, Doberaner Str 137-139, D-18057 Rostock, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 11期
关键词
friction coefficient; friction conditions; insertion force; insertion speed; insertion trauma; cochlear electrode array; IMPLANT ELECTRODES; COMPUTED-TOMOGRAPHY; TEMPORAL BONE; LOCATION; DESIGN; TRAUMA; DAMAGE; MODEL;
D O I
10.3390/app11115162
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: During cochlear implantation, the electrode array has significant friction with the sensitive endocochlear lining and causes mutual mechanical trauma while the array is being inserted. Both, the impact of insertion speed on electrode friction and the relationship of electrode insertion force and friction have not been adequately investigated to date. Methods: In this study, friction coefficients between a CI electrode array (31.5 mm) and a tissue simulating the endocochlear lining have been acquired, depending on different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s). Additionally, the electrode insertion forces during the placing into a scala tympani model were recorded and correlated with the friction coefficient. Results: It was shown that the friction coefficient reached the lowest value at an insertion speed of 0.1 mm/s (0.24 +/- 0.13), a maximum occurred at 1.5 mm/s (0.59 +/- 0.12), and dropped again at 2 mm/s (0.45 +/- 0.11). Similar patterns were observed for the insertion forces. Consequently, a high correlation coefficient (0.9) was obtained between the insertion forces and friction coefficients. Conclusion: The present study reveals a non-linear increase in electrode array friction, when insertion speed raises and reports a high correlation between friction coefficient and electrode insertion force. This dependence is a relevant future parameter to evaluate and reduce cochlear implant insertion trauma. Significance statement: Here, we demonstrated a dependence between cochlear electrode insertion speed and its friction behavior and a high correlation to insertion force. Our study provides valuable information for the evaluation and prevention of cochlear implant insertion trauma and supports the optimization of cochlear electrode arrays regarding friction characteristics.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion
    Xu, Yuchen
    Luo, Chuan
    Zeng, Fan-Gang
    Middlebrooks, John C.
    Lin, Harrison W.
    You, Zheng
    MICROMACHINES, 2018, 9 (05)
  • [22] Prolonged Insertion Time Reduces Translocation Rate of a Precurved Electrode Array in Cochlear Implantation
    van der Jagt, Annerie M. A.
    Briaire, Jeroen J.
    Boehringer, Stefan
    Verbist, Berit M.
    Frijns, Johan H. M.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (04) : E427 - E434
  • [23] Effect of deep insertion of the cochlear implant electrode array on pitch estimation and speech perception
    Hamzavi, Jafar
    Arnoldner, Christoph
    ACTA OTO-LARYNGOLOGICA, 2006, 126 (11) : 1182 - 1187
  • [24] Intraoperative Impedance-Based Estimation of Cochlear Implant Electrode Array Insertion Depth
    Aebischer, Philipp
    Meyer, Stefan
    Caversaccio, Marco
    Wimmer, Wilhelm
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (02) : 545 - 555
  • [25] Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion
    Tae Mok Gwon
    Kyou Sik Min
    Jin Ho Kim
    Seung Ha Oh
    Ho Sun Lee
    Min-Hyun Park
    Sung June Kim
    Biomedical Microdevices, 2015, 17
  • [26] Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion
    Gwon, Tae Mok
    Min, Kyou Sik
    Kim, Jin Ho
    Oh, Seung Ha
    Lee, Ho Sun
    Park, Min-Hyun
    Kim, Sung June
    BIOMEDICAL MICRODEVICES, 2015, 17 (02)
  • [27] A novel intraoperative imaging tool to follow the cochlear implant electrode array insertion dynamics
    Adam, Perenyi
    Roland, Nagy
    Bence, Horvath
    Balint, Posta
    Balazs, Dimak
    Miklos, Csanady
    Geza, Kiss Jozsef
    Laszlo, Rovo
    ORVOSI HETILAP, 2021, 162 (22) : 878 - 883
  • [28] Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size, and depth of insertion
    Rebscher, Stephen J.
    Hetherington, Alexander
    Bonham, Ben
    Wardrop, Peter
    Whinney, David
    Leake, Patricia A.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (05): : 731 - 747
  • [29] Cochlear Implant Insertion Axis Into the Basal Turn: A Critical Factor in Electrode Array Translocation
    Torres, Renato
    Drouillard, Mylene
    De Seta, Daniele
    Bensimon, Jean-Loup
    Ferrary, Evelyne
    Sterkers, Olivier
    Bernardeschi, Daniele
    Nguyen, Yann
    OTOLOGY & NEUROTOLOGY, 2018, 39 (02) : 168 - 176
  • [30] Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing
    Anagiotos, Andreas
    Beutner, Dirk
    Gostian, Antoniu-Oreste
    Schwarz, David
    Luers, Jan-Christoffer
    Huettenbrink, Karl-Bernd
    OTOLOGY & NEUROTOLOGY, 2016, 37 (04) : 339 - 344