Indirect determination of low vapour pressures using solid-phase microextraction -: application to tetrachlorobenzenes and tetrachlorobenzyltoluenes

被引:7
|
作者
Paschke, A [1 ]
Schröter, U [1 ]
Schüürmann, G [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Chem Ecotoxicol, Ctr Environm Res Leipzig, D-04318 Leipzig, Germany
关键词
vapour pressure; solid-phase microextraction; chlorobenzenes; hexachlorocyclohexane isomers; DDT; polychlorinated biphenyls; tetrchlorobenzyltoluenes;
D O I
10.1016/j.chroma.2005.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is still a gap of reliable vapour pressure data at ambient temperature for low volatile organic substances due to the difficult and time-consuming determination using the classical methods. Static headspace extraction with a solid-phase microextraction (SPME) fibre in combination with gas chromatographic analysis provides an inexpensive tool for the indirect determination of low vapour pressures down to 10(-5) Pa. The procedure consists of two steps: (a) exposure of SPME fibre in the headspace above the test chemical over minutes to hours and (b) desorption and quantification of extracted amount. The calibration was performed using low volatile reference substances with well-known vapour pressures. A good correlation was found between substance uptakes of SPME fibre and vapour pressures. The method was applied, e.g. to tetrachlorobenzenes and to selected tetrachlorobenzyltoluenes with questionable vapour pressures. We obtained values between 0.98 and 13.5 Pa for the former and results between 0.13 and 0.68 mPa for the latter group of congeners. The scope of the method can be extended to substances with even lower vapour pressures, provided that reliable reference data are available. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 50 条
  • [31] Static headspace, solid-phase microextraction and headspace solid-phase microextraction for BTEX determination in aqueous samples by gas chromatography
    Menéndez, JCF
    Sánchez, MLF
    Uría, JES
    Martínez, EF
    Sanz-Medel, A
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 9 - 20
  • [32] Application of low-temperature glassy carbon films in solid-phase microextraction
    Giardina, M
    Olesik, SV
    ANALYTICAL CHEMISTRY, 2001, 73 (24) : 5841 - 5851
  • [33] Determination of low-level residual ethylene oxide by using solid-phase microextraction and gas chromatography
    Ayoub, K
    Harris, L
    Thompson, B
    JOURNAL OF AOAC INTERNATIONAL, 2002, 85 (06) : 1205 - 1209
  • [34] Determination of volatile organic compounds by solid-phase microextraction
    T. A. Misharina
    M. B. Terenina
    N. I. Krikunova
    Applied Biochemistry and Microbiology, 2017, 53 : 600 - 609
  • [35] Solid-phase microextraction for herbicide determination in environmental samples
    Krutz, LJ
    Senseman, SA
    Sciumbato, AS
    JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) : 103 - 121
  • [36] Determination of benzene derivatives in water by solid-phase microextraction
    Huang, SD
    Cheng, CP
    Sung, YH
    ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) : 101 - 108
  • [37] OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS
    BUCHHOLZ, KD
    PAWLISZYN, J
    ANALYTICAL CHEMISTRY, 1994, 66 (01) : 160 - 167
  • [38] Determination of organophosphorus pesticides in water by solid-phase microextraction
    Su, PG
    Huang, SD
    TALANTA, 1999, 49 (02) : 393 - 402
  • [39] Determination of Volatile Organic Compounds by Solid-Phase Microextraction
    Misharina, T. A.
    Terenina, M. B.
    Krikunova, N. I.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2017, 53 (05) : 600 - 609
  • [40] Gas chromatographic determination of formaldehyde in air using solid-phase microextraction sampling
    Ŝ. Velikonja Bolta
    L. Zupanĉiĉ-Kralj
    J. Marsel
    Chromatographia, 1998, 48 : 95 - 100