Usefulness of a novel electrosurgical knife, the insulation-tipped diathermic knife-2, for endoscopic submucosal dissection of early gastric cancer

被引:131
|
作者
Ono, Hiroyuki [1 ]
Hasuike, Noriaki [1 ]
Inui, Tetsuya [1 ]
Takizawa, Kohei [1 ]
Ikehara, Hisatomo [1 ]
Yamaguchi, Yuichiro [1 ]
Otake, Yosuke [1 ]
Matsubayashi, Hiroyuki [1 ]
机构
[1] Shizuoka Canc Ctr Hosp, Div Endoscopy & GI Oncol, Nagaizumi, Shizuoka 4118777, Japan
关键词
IT knife 2; ESD; gastric cancer;
D O I
10.1007/s10120-008-0452-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Although endoscopic submucosal dissection (ESD) of early gastric cancer using an insulation-tipped diathermic (IT) knife enables the removal of large and ulcerative lesions en bloc, expert endoscopic skill is required. We developed an improved IT knife (IT-2) and compared its efficacy and safety with that of the original IT knife (IT-OM). Methods. We performed ESD of 602 gastric cancers. Of these, 314 previously untreated single lesions of initial onset were analyzed. Operating time, rate of en-bloc resection, and incidence of complications were compared in the IT-2 group (161 patients) and IT-OM group (153 patients). Lesions were further analyzed as to whether they met the Japanese Gastric Cancer Association indications for ESD or extended indications. Results. Mean resection time was significantly shorter in the IT-2 than in the IT-OM group (48 vs 63 min). There were fewer surgeries lasting longer than 2 h in the IT-2 group than in the IT-OM group (3% vs 12%). En-bloc and margin-free resection rates in the IT-OM and IT-2 groups were 95% and 99%, respectively. Perforations occurred in 3.9% of patients in the IT-OM group and in 5% of patients in the IT-2 group (difference not significant [ NS]). The incidence of postoperative hemorrhage was 7.8% in the IT-OM group and 8.7% in the IT-2 group (NS). In both groups, complications were treated endoscopically, and emergency surgery was unnecessary. Conclusion. Resectability and complication rates were similar in the two groups. However, operating time was shorter with IT-2, irrespective of the indications for the performance of ESD. This study suggests benefits of the IT-2 over the IT-OM.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [31] SUBMUCOSAL DISSECTION OF GASTRIC NEOPLASMS WITH MUCOSECTOM AND IT KNIFE-2: A RETROSPECTIVE, COHORT STUDY
    Viale, E.
    Notaristefano, C.
    Testoni, P. A.
    DIGESTIVE AND LIVER DISEASE, 2014, 46 : S83 - S84
  • [32] Novel electrosurgical knife with adjustable sheath length for colorectal endoscopic submucosal dissection
    Nomura, Tatsuma
    Sugimoto, Shinya
    Oyamada, Jun
    DIGESTIVE ENDOSCOPY, 2022, 34 (03) : E30 - E31
  • [33] Thoracoscopic en-bloc pleural biopsy using an insulation-tipped diathermic knife for unexplained pleural effusion
    Sasada, Shinji
    Kawahara, Kunimitsu
    Kobayashi, Masashi
    Iwasaki, Teruo
    Michida, Tomoki
    Hirashima, Tomonori
    Suzuki, Hidekazu
    Okamoto, Norio
    Matsui, Kaoru
    Miyazawa, Teruomi
    JOURNAL OF THORACIC ONCOLOGY, 2007, 2 (08) : S368 - S368
  • [34] Comparison between a novel core knife and the conventional IT knife 2 for endoscopic submucosal dissection of gastric mucosal lesions
    Park, Myeongsoon
    Lee, Jin Wook
    Shin, Dong Woo
    Kim, Jungseok
    Lee, Yoo Jin
    Lee, Ju Yup
    Cho, Kwang Bum
    CLINICAL ENDOSCOPY, 2022, 55 (06) : 767 - 774
  • [35] A new endoscopic mucosal resection procedure using an insulation-tipped electrosurgical knife for rectal flat lesions: report of two cases
    Gotoda, T
    Kondo, H
    Ono, H
    Saito, Y
    Yamaguchi, H
    Saito, D
    Yokota, T
    GASTROINTESTINAL ENDOSCOPY, 1999, 50 (04) : 560 - 563
  • [36] Semirigid Thoracoscopic Full Thickness Pleural Biopsy Using an Insulation-tipped Diathermic Knife for Unexplained Pleural Effusion
    Sasada, S.
    Kawahara, K.
    Kobayashi, M.
    Iwasaki, T.
    Michida, T.
    Hirashima, T.
    Suzuki, H.
    Okamoto, N.
    Matsui, K.
    Miyazawa, T.
    Shinji, S.
    Kobayashi, M.
    Hirashima, T.
    Suzuki, H.
    Okamoto, N.
    Matsui, K.
    Kawahara, K.
    Iwasaki, T.
    Michida, T.
    Miyazawa, T.
    PROCEEDINGS OF THE 15TH WORLD CONGRESS FOR BRONCHOLOGY (WCB) AND 15TH WORLD CONGRESS FOR BRONCHOESOPHAGOLOGY (WCBE), 2008, : 83 - 91
  • [37] Pleural MALT lymphoma diagnosed on thoracoscopic resection under local anesthesia using an insulation-tipped diathermic knife
    Kawahara, Kunimitsu
    Sasada, Shinji
    Nagano, Teruaki
    Suzuki, Hidekazu
    Kobayashi, Masashi
    Matsui, Kaoru
    Takata, Katsuyoshi
    Yoshino, Tadashi
    Michida, Tomoki
    Iwasaki, Teruo
    PATHOLOGY INTERNATIONAL, 2008, 58 (04) : 253 - 256
  • [38] Treatment of gastric epithelial tumours by endoscopic submucosal dissection using an insulated-tip diathermic knife
    Hua, Xu Li
    Bo, Qian Jun
    Gen, Gu Liu
    Fei, Lu
    Min, Wang Ya
    Ming, Li Yu
    Sheng, Lu Hua
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 25 (02) : 97 - 101
  • [39] Clutch Cutter knife efficacy in endoscopic submucosal dissection for early gastric neoplasms
    Yasuyo Hayashi
    Mitsuru Esaki
    Sho Suzuki
    Eikichi Ihara
    Azusa Yokoyama
    Seiichiro Sakisaka
    Taizo Hosokawa
    Yoshimasa Tanaka
    Takahiro Mizutani
    Shinichi Tsuruta
    Aya Iwao
    Shun Yamakawa
    Akira Irie
    Yosuke Minoda
    Yoshitaka Hata
    Haruei Ogino
    Hirotada Akiho
    Yoshihiro Ogawa
    World Journal of Gastrointestinal Oncology, 2018, 10 (12) : 487 - 495
  • [40] Clutch Cutter knife efficacy in endoscopic submucosal dissection for early gastric neoplasms
    Hayashi, Yasuyo
    Esaki, Mitsuru
    Suzuki, Sho
    Ihara, Eikichi
    Yokoyama, Azusa
    Sakisaka, Seiichiro
    Hosokawa, Taizo
    Tanaka, Yoshimasa
    Mizutani, Takahiro
    Tsuruta, Shinichi
    Iwao, Aya
    Yamakawa, Shun
    Irie, Akira
    Minoda, Yosuke
    Hata, Yoshitaka
    Ogino, Haruei
    Akiho, Hirotada
    Ogawa, Yoshihiro
    WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2018, 10 (12) : 487 - 495