Wave length shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules

被引:0
|
作者
Braem, A. [1 ,2 ]
Chesi, E. [1 ,2 ]
Joram, C. [1 ,2 ]
Rudge, A. [1 ,2 ]
Seguinot, J. [1 ,2 ]
Weilhammer, P. [1 ,2 ]
De Leo, R. [3 ]
Nappi, E. [3 ]
Lustermann, W. [4 ]
Schinzel, D. [4 ]
Johnson, I. [5 ]
Renker, D. [5 ]
Albrecht, S. [6 ]
机构
[1] CERN, PH Dept, CH-1211 Geneva, Switzerland
[2] Univ INFN Perugia, I-06100 Perugia, Italy
[3] Ist Nazl Fis Nucl, Sezione Bari, I-70122 Bari, Italy
[4] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
[5] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[6] Univ Hosp, CH-1211 Geneva, Switzerland
关键词
D O I
10.1109/NSSMIC.2007.4436681
中图分类号
O59 [应用物理学];
学科分类号
摘要
The measurements presented in this paper are related to the development of a PET camera based on a 3D axial geometry with excellent 3-dimensional spatial, timing and energy resolution. The detector modules under development consist of matrices of long axially oriented scintillation crystal bars, which are individually coupled to photodetectors. The axial coordinate is derived from Wave Length Shifting (WLS) plastic strips orthogonally interleaved between the crystal bars and readout by G-APD arrays. We report on results from measurements with two LYSO crystal bars, read with PMTs, and two WLS strips readout with G-APD devices from Hamamatsu (called MPPC). The WLS strips are positioned orthogonally underneath the LYSO bars. Yields of about 80 photoelectrons from the WLS strips for an energy deposition in the LYSO crystals equivalent to the absorption of 511 keV photons are observed. The axial coordinate in the LYSO bars is reconstructed with a precision of about 1.9 mm (FWHM) using a digital reconstruction method. This resolution is still compromised by the availability of only two WLS strips and will improve with a full stack of LYSO crystals interleaved with WLS strip arrays, which is presently under development for a PET demonstrator set-up.
引用
收藏
页码:2601 / +
页数:2
相关论文
共 3 条
  • [1] Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules
    Braem, A.
    Chesi, E.
    Joram, C.
    Rudge, A.
    Seguinot, J.
    Weilhammer, P.
    De Leo, R.
    Nappi, E.
    Lustermann, W.
    Schinzel, D.
    Johnson, I.
    Renker, D.
    Albrecht, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 300 - 308
  • [2] Experimental characterization of novel small animal PET detector modules based on scintillation crystal blocks read out by APD arrays
    Maas, MC
    van der Laan, DJ
    Schaart, DR
    Huizenga, J
    Brouwer, JC
    Bruyndonckx, P
    Léonard, S
    Lemaître, C
    van Eijk, CWE
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2942 - 2946
  • [3] High precision axial coordinate readout for an axial 3-D PET detector module using a wave length shifter strip matrix
    Braem, A.
    Chesi, E.
    Joram, C.
    Seguinot, J.
    Weilhammer, P.
    De Leo, R.
    Nappi, E.
    Lustermann, W.
    Schinzel, D.
    Johnson, I.
    Renker, D.
    Albrecht, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03): : 1513 - 1521