Evaluating the calibration of MTSAT-1R infrared channels using collocated Terra MODIS measurements

被引:16
|
作者
Sohn, Byung-Ju [1 ]
Park, Hye-Sook [1 ]
Han, Hyo-Jin [1 ]
Ahn, Myoung-Hwan [2 ]
机构
[1] Seoul Natl Univ, Sch Earth & Environm Sci, Seoul 156720, South Korea
[2] Meteorol Res Inst, Seoul, South Korea
关键词
D O I
10.1080/01431160701408394
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
The calibration of four MTSAT-1R infrared channels was evaluated by comparing MTSAT measurements with Terra/MODIS inferred MTSAT-equivalent brightness temperatures during August 2005 and August 2006. Theoretical relationships converting MODIS brightness temperatures to MTSAT-equivalent values were obtained and used for the comparison. Results indicate that MTSAT two split window channels are well calibrated, and no serious systematic errors or biases are found; and the MTSAT water-vapour channel shows a good linear relationship but with a warm bias up to 2K. The significant cold bias of MTSAT 3.7m channel about -6.7K in August 2005 is found to be much removed in August 2006, after correction of the electrical crosstalk between MTSAT-1R SWIR channel and WV channel starting from March 2006. Since then, calibration performances of MTSAT-1R split window channels and shortwave IR channel seem to be comparable with MODIS calibration, while the water-vapour channel shows more uncertainties up to 2K of bias.
引用
收藏
页码:3033 / 3042
页数:10
相关论文
共 30 条
  • [21] Cross-calibration of FY-2E/VISSR infrared window and water vapor channels with TERRA/MODIS
    Xu Na
    Hu Xiu-Qing
    Chen Lin
    Zhang Yu-Xiang
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (04) : 319 - +
  • [22] Statistical Analysis of the Life Cycle of Isolated Tropical Cold Cloud Systems Using MTSAT-1R and TRMM Data
    Imaoka, Keiji
    Nakamura, Kenji
    MONTHLY WEATHER REVIEW, 2012, 140 (11) : 3552 - 3572
  • [23] Calibration of the DSCOVR EPIC visible and NIR channels using MODIS Terra and Aqua data and EPIC lunar observations
    Geogdzhayev, Igor V.
    Marshak, Alexander
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (01) : 359 - 368
  • [26] Assessment of Terra MODIS Thermal emissive band calibration using cold targets and measurements in lunar roll events
    Chang, Tiejun
    Xiong, Xiaoxiong
    Shrestha, Ashish
    Wu, Aisheng
    Chen, Na
    Li, Yonghong
    Mu, Qiaozhen
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXII, 2018, 10785
  • [27] A vicarious calibration for thermal infrared bands of TERRA-MODIS sensor using a new calibration test site-lake Dali, China
    Zhu Li
    Gu Xingfa
    Zhang Yuxiang
    Yu Tao
    Chen Liangfu
    Gong Hui
    Huai Hongyan
    IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 4113 - +
  • [28] Radiometric Cross-Calibration of EO-1 ALI With L7 ETM+ and Terra MODIS Sensors Using Near-Simultaneous Desert Observations
    Chander, Gyanesh
    Angal, Amit
    Choi, Taeyoung
    Xiong, Xiaoxiong
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) : 386 - 399
  • [29] Cross-calibration of the Terra MODIS, Landsat 7 ETM+ and EO-1 ALI sensors using near-simultaneous surface observation over the Railroad Valley Playa, Nevada, test site
    Chander, Gyanesh
    Angal, Amit
    Choi, Taeyoung Jason
    Meyer, David J.
    Xiong, Xiaoxiong Jack
    Teillet, Philippe M.
    EARTH OBSERVING SYSTEMS XII, 2007, 6677
  • [30] CALIBRATION OF VISIBLE AND NEAR-INFRARED CHANNELS OF THE FY1C USING TIME-SERIES OBSERVATION BASED ON PSEUDO-INVARIANT TARGET SITES IN CHINA
    Gao, Hailiang
    Gu, Xingfa
    Yu, Tao
    Hu, Xiuqing
    Li, Xiaoying
    Gong, Hui
    Li, Jiaguo
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 1702 - 1705