Anterior-Segment Swept-Source Ocular Coherence Tomography and Scheimpflug Imaging Agreement for Keratometry and Pupil Measurements in Healthy Eyes

被引:4
|
作者
Perez-Bartolome, Francisco [1 ,2 ]
Rocha-De-Lossada, Carlos [3 ,4 ,5 ]
Sanchez-Gonzalez, Jose-Maria [6 ]
Feu-Basilio, Silvia [2 ]
Torras-Sanvicens, Josep [2 ]
Peraza-Nieves, Jorge [2 ]
机构
[1] Hosp Univ Puerta Hierro, Dept Ophthalmol, Majadahonda 28222, Spain
[2] Univ Barcelona, Hosp Clin Barcelona, Clin Inst Ophthalmol, Dept Ophthalmol, Barcelona 08036, Spain
[3] Vithas Virgen Mar Hosp, Dept Ophthalmol Qvis, Almeria 04120, Spain
[4] Hosp Virgen Las Nieves, Dept Ophthalmol, Granada 18014, Spain
[5] Ceuta Med Ctr, Dept Ophthalmol, Ceuta 51001, Spain
[6] Univ Seville, Pharm Fac, Dept Condensed Matter Phys, Opt Area,Vis Sci Res Grp CIVIUS, Seville 41012, Spain
关键词
anterior-segment swept-source; ocular coherence tomography; Scheimpflug imaging; agreement analysis; pupil measurements; ANGLE KAPPA; IMPLANTATION; ABERRATIONS; THICKNESS; LASIK; OCT;
D O I
10.3390/jcm10245789
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examines agreement between the devices Anterion(R) and Pentacam HR(R) used for corneal and pupil measurements in healthy eyes. The parameters compared between the two devices were: anterior Km (D), anterior K2 (D), anterior K1 (D), anterior K1 axis (degrees), anterior astigmatism (D), anterior K max (D), posterior Km (D), posterior K2 (D), posterior K1 (D), posterior K1 axis (degrees), posterior astigmatism (D), CCT (mu m), thinnest point thickness (mu m), thinnest point X-coordinate (mm), thinnest point Y-coordinate (mm), pupil diameter (mm), pupil center-corneal vertex distance (mm) (angle kappa), pupil centroid angle (degrees), pupil centroid X-coordinate (mm), and pupil centroid Y-coordinate (mm). The Student's t test for independent samples identified significant differences (p < 0.005) between devices for the measurements anterior and posterior flat K axis, posterior flat K, steep K, and mean K. For these last three measurements, although significant, none of the differences were clinically relevant. Corneal power and thickness measurements except Kf axis showed excellent agreement between Anterion and Pentacam. In a clinical setting we would not recommend the interchangeable use of Pentacam and Anterion for measurement of pupil parameters.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Anterior-segment swept-source ocular coherence tomography and scheimpflug imaging agreement for keratometry and pupil measurements in healthy eyes
    Bartolome, Francisco Perez
    Gonzalez, Rocio Vega
    Nieves, Jorge Peraza
    Moreno, Jose Maria Ruiz
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [2] Agreement in anterior segment measurements between swept-source optical coherence and dual Scheimpflug tomography devices in keratoconus eyes
    Yunjin Lee
    Joo Youn Oh
    Hyuk Jin Choi
    Mee Kum Kim
    Chang Ho Yoon
    Scientific Reports, 14 (1)
  • [3] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [4] Agreement between Scheimpflug–Placido topographer (Sirius®) and anterior-segment swept-source optical coherence tomography (ANTERİON®) devices for corneal high order aberrations in keratoconic and healthy eyes
    Furkan Ozer
    Metin Unlu
    Kubra Erdogan
    Kuddusi Erkilic
    International Ophthalmology, 45 (1)
  • [5] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Seyed Mohammad Ghoreishi
    Seyed Ali Akbar Mortazavi
    Zahra-Alsadat Abtahi
    Mohammad-Ali Abtahi
    Seyed Ali Sonbolestan
    Seyed-Hossein Abtahi
    Mohadeseh Mohammadinia
    Kimia Nekouie Isfahani
    International Ophthalmology, 2017, 37 : 965 - 971
  • [6] Repeatability of Keratometry Measurements with Swept-Source Optical Coherence Tomography in Normal Eyes
    Poulsen, Anne
    Cui, Amy Lu David
    Seeger, Catherine
    Lehman, Erik
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [7] Pigmented Iris Lesion on Anterior-Segment Swept-Source Optical Coherence Tomography
    Vaidya, Sarangdev
    Yaghy, Antonio
    Shields, Carol L.
    JAMA OPHTHALMOLOGY, 2021, 139 (01)
  • [8] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Bartolome, Francisco Perez
    Gonzalez, Rocio Vega
    Nieves, Jorge Peraza
    Moreno, Jose Maria Ruiz
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [9] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Perez-Bartolome, Francisco
    Feu-Basilio, Silvia
    Rocha-de Lossada, Carlos
    Blanco-Dominguez, Irene
    Torras-Sanvicens, Josep
    Peraza-Nieves, Jorge
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3363 - 3371
  • [10] The evaluation of corneal tomography using swept-source optical coherence tomography and Scheimpflug imaging in healthy and ectasia eyes
    Herber, Robert
    Pillunat, Lutz E.
    Raiskup, Frederik
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)