Performance study of a DC-corona-based particle charger for charge conditioning

被引:25
|
作者
Li, Lin [1 ]
Chen, Da-Ren [1 ]
机构
[1] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
关键词
Unipolar particle charging; Particle charge conditioning; DC corona discharge; Charging ion concentration control; ELECTRICAL AEROSOL CHARGERS; DIFFUSION CHARGER; UNIPOLAR; NANOPARTICLES; DEPOSITION; IONS; CALIBRATION; NEUTRALIZER; TRANSITION; MOBILITY;
D O I
10.1016/j.jaerosci.2010.12.001
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new DC-corona-based charge conditioner for particles was developed for the processes in which electrical charges on particles are critical to successful operations. The prototype conditioner consists of an outer metal case and a corona discharge tube module capped with a metal screen at one end. A pointed tungsten needle was used in the tube module to produce ions via corona discharge. Ions produced in the tube module were driven into particle charging zone via the voltage difference between the module and conditioner cases. The particle charging zone of the conditioner was designed for quick particle exit once the particles are electrically charged, thus reducing the loss of charged particles. Two unique design features were included in the prototype conditioner, i.e., the implementation of parallel directions of electrical and aerosol flow fields, and variable control of ion concentration in the charging zone. Through the experimental evaluation, we found that the conditioner achieved its highest extrinsic charging efficiency, equivalent or higher than those of existed DC-corona-based particle chargers, when operated at the condition of a 3 lpm (liters per minute) aerosol flow rate, a 2 mu A corona current and a 600 V ion-driving voltage. A tandem-DMA technique was utilized to characterize extrinsic charge distributions of particles with various sizes. Last, the birth-and-death charging model with the Fuchs limiting sphere theory for calculating the ion-particle combination coefficient was applied to obtain the charging ion concentration under the various operations of the prototype. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:87 / 99
页数:13
相关论文
共 50 条
  • [21] Study on corona performance of insulators based on the UV puise detecting method
    Wang, Can-Lin
    Wang, Ke
    Wang, Li-Ming
    Guan, Zhi-Cheng
    Liao, Yong-Li
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (36): : 19 - 25
  • [22] Particle charge in PK-4 dc discharge from ground-based and microgravity experiments
    Antonova, T.
    Khrapak, S. A.
    Pustylnik, M. Y.
    Rubin-Zuzic, M.
    Thomas, H. M.
    Lipaev, A. M.
    Usachev, A. D.
    Molotkov, V. I.
    Thoma, M. H.
    PHYSICS OF PLASMAS, 2019, 26 (11)
  • [23] Study of the Solar Wind Plasma Thermodynamics in the Solar Corona Based on the Charge State of Heavy Ions
    F. F. Goryaev
    V. A. Slemzin
    Astronomy Letters, 2024, 50 (6) : 408 - 419
  • [24] A novel exergy based charge optimisation for a mobile air conditioning systemAn experimental study
    R. Prabakaran
    D. Mohan Lal
    Journal of Thermal Analysis and Calorimetry, 2018, 132 : 1241 - 1252
  • [25] Study on Capture Efficiency of Particle Trap and Performance Improvement Method for DC GIL/GIS
    Zhang, Yutong
    Wu, Zehua
    Xin, Luming
    Ding, Ke
    Tan, Shengwu
    Wang, Gang
    Liu, Peng
    Peng, Zongren
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (05) : 2258 - 2266
  • [26] Study on the Corona Discharge Ionized Field of UHVdc Based on Particle-in-Cell Iterative Method
    Zhu, Ting
    Wang, Shuhong
    Guo, Ze
    Wang, Song
    Zhang, Naming
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (06)
  • [27] Experimental performance study of a proposed desiccant based air conditioning system
    Bassuoni, M. M.
    JOURNAL OF ADVANCED RESEARCH, 2014, 5 (01) : 87 - 95
  • [28] Evaluation of dc insulation performance based on space-charge measurements and accelerated life tests
    Montanari, GC
    Fabiani, D
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2000, 7 (03) : 322 - 328
  • [29] Study on DC modulation for AC/DC hybrid transmission system based on comprehensive performance index
    Wu, Hua-Jian
    Wang, Yu-Hong
    Li, Xing-Yuan
    Wei, Wei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (22): : 68 - 73
  • [30] Improving Urban Air Quality Measurements by a Diffusion Charger Based Electrical Particle Sensors - A Field Study in Beijing, China
    Dal Maso, Miikka
    Gao, Jian
    Jarvinen, Anssi
    Li, Hui
    Luo, Datong
    Janka, Kauko
    Ronkko, Topi
    AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (12) : 3001 - 3011