The determination of perphenazine by a new simple flow-injection chemiluminescence method

被引:4
|
作者
Han, XN [1 ]
Tang, YH [1 ]
Yu, CL [1 ]
Zheng, XH [1 ]
Jin, QJ [1 ]
机构
[1] Xi An Jiao Tong Univ, Coll Sci, Dept Chem, Xian 710061, Peoples R China
关键词
flow injection; chemiluminescence; perphenazine; pharmaceutical tablet;
D O I
10.1080/00032710500232729
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple flow-injection chemiluminescence (CL) method is described for the determination of perphenazine, which is based on the CL intensity that generated from the redox reaction of Ce (IV)-perphenazine in HNO3 medium is proportional to the perphenazine concentration without any sensitizers. The proposed method allows the determination range within 1.0x10(-7) -7.0 x10(-5) g mL(-1) with a detection limit of 8.0x10(-8) g mL(-1) (,) and it has been successfully applied to the determination of the perphenazine in pharmaceutical tablet compared well with the official method.
引用
收藏
页码:1933 / 1941
页数:9
相关论文
共 50 条
  • [21] A Simple flow-injection spectrofluorimetric method for the determination of mercury
    Andac, Muberra
    Asan, Adem
    Tinkilic, Nihat
    Isildak, Ibrahim
    [J]. JOURNAL OF FLUORESCENCE, 2007, 17 (04) : 401 - 405
  • [22] A Simple Flow-injection Spectrofluorimetric Method for the Determination of Mercury
    Muberra Andac
    Adem Asan
    Nihat Tinkilic
    Ibrahim Isildak
    [J]. Journal of Fluorescence, 2007, 17 : 401 - 405
  • [23] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [24] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    [J]. ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [25] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    [J]. LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [26] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    [J]. ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [27] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    [J]. TALANTA, 2007, 71 (02) : 900 - 905
  • [28] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667
  • [29] Flow-injection chemiluminescence determination of haemoglobin in the blood
    Traore, Zoumana Sekou
    Shah, Syed Mazhar
    Su, Xingguang
    [J]. LUMINESCENCE, 2013, 28 (01) : 56 - 62
  • [30] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao, Zhi-Ming
    Zou, Ping
    Chen, Mei
    Xiu, Fu-Rong
    Chen, Yu-Lin
    Hong, Ke-Jun
    [J]. Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2008, 28 (02): : 269 - 272