Determination of carbon monoxide in tuna by gas chromatography with micro-thermal conductivity detector

被引:22
|
作者
Bernardi, Cristian [1 ]
Chiesa, Luca Maria [1 ]
Soncin, Silvia [1 ]
Passero, Elena [1 ]
Biondi, Pier Antonio [1 ]
机构
[1] Univ Milan, Dept Vet Sci & Technol Food Safety, I-20133 Milan, Italy
关键词
D O I
10.1093/chromsci/46.5.392
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The suitability of a portable gas chromatograph equipped with a micro-thermal conductivity detector for the head-space determination of carbon monoxide (CO) in tuna samples is evaluated; CO is estimated after its liberation from tissue by acidic treatment at 70°C. Using the tested technique, the CO contents in untreated and suspected treated samples are analyzed. A limit of detection of approximately 13 ng/g is reached. The results demonstrate that this apparatus has performances similar to more expensive and sophisticated instruments.
引用
收藏
页码:392 / 394
页数:3
相关论文
共 50 条
  • [21] Micro-thermal analysis and evolved gas analysis
    Price, DM
    Reading, M
    Lever, TJ
    Hammiche, A
    Pollock, HM
    THERMOCHIMICA ACTA, 2001, 367 : 195 - 202
  • [22] DETERMINATION OF CARBON-MONOXIDE CONCENTRATIONS IN AIR BY GAS-CHROMATOGRAPHY USING AN ARGON IONIZATION DETECTOR
    POPP, P
    OPPERMANN, G
    JOURNAL OF CHROMATOGRAPHY, 1978, 148 (01): : 265 - 268
  • [23] Two-Port Static Coated Micro Gas Chromatography Column With an Embedded Thermal Conductivity Detector
    Shree Narayanan
    Alfeeli, Bassam
    Agah, Masoud
    IEEE SENSORS JOURNAL, 2012, 12 (06) : 1893 - 1900
  • [24] Thermostatted Micro Gas Chromatography Column with On-chip Thermal Conductivity Detector for Elevated Temperature Separation
    Narayanan, Shree
    Alfeeli, Bassam
    Agah, Masoud
    2010 IEEE SENSORS, 2010, : 2504 - 2507
  • [25] EFFECT OF THE CARRIER GAS ON THE SENSITIVITY OF A THERMAL-CONDUCTIVITY DETECTOR IN GAS CHROMATOGRAPHY
    SCHMAUCH, LJ
    DINERSTEIN, RA
    NATURE, 1959, 183 (4662) : 673 - 674
  • [27] Localised Evolved Gas Analysis by Micro-thermal Analysis
    D. M. Price
    M. Reading
    R. M. Smith
    H. M. Pollock
    A. Hammiche
    Journal of Thermal Analysis and Calorimetry, 2001, 64 : 309 - 314
  • [28] DETERMINATION OF THE NITROGEN CONCENTRATION IN ARGON ON PPM LEVEL BY GAS-CHROMATOGRAPHY WITH A THERMAL-CONDUCTIVITY DETECTOR
    LASA, J
    DROZDOWICZ, B
    KORUS, A
    CHEMIA ANALITYCZNA, 1994, 39 (06): : 735 - 739
  • [29] ELECTRODELESS DISCHARGE AS DETECTOR IN GAS CHROMATOGRAPHY .4. COMPARISON WITH A THERMAL CONDUCTIVITY DETECTOR
    ARNIKAR, HJ
    RAO, TS
    KARMARKA.KH
    JOURNAL OF CHROMATOGRAPHY, 1968, 38 (01): : 126 - &
  • [30] Localised evolved gas analysis by micro-thermal analysis
    Price, DM
    Reading, M
    Smith, RM
    Pollock, HM
    Hammiche, A