Plan complexity quantification of dual-layer multi-leaf collimator for volumetric modulated arc therapy with Halcyon linac

被引:21
|
作者
Tamura, Mikoto [1 ]
Matsumoto, Kenji [2 ]
Otsuka, Masakazu [1 ,2 ]
Monzen, Hajime [1 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Onohigashi, Osakasayama, Osaka 5898511, Japan
[2] Kindai Univ Hosp, Dept Radiol, 377-2 Onohigashi, Osakasayama, Osaka 5898511, Japan
关键词
Plan complexity; Dual-layer MLC; Halcyon; VMAT; GAMMA INDEX ANALYSIS; QUALITY-ASSURANCE; IMRT; VMAT; METRICS;
D O I
10.1007/s13246-020-00891-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study characterized the plan complexity of the dual-layer multi-leaf collimator (MLC) performance for volumetric modulated arc therapy (VMAT) in Halcyon. Plan complexity metrics were computed independently for each MLC layer (proximal and distal): modulation complexity score (MCS), plan averaged beam area, irregularity, and modulation (PA, PI, and PM) were obtained. These were investigated when weighted by proportions of the effective proximal MLC and distal MLC (MCSw, PA(w), PIw, and PMw). Conventional plan complexity metrics for the effective 5.0 mm resolution MLC (MCS5, PA(5), PI5, PM5), small aperture score (SAS), effective distal MLC score (EDS), and MU were also evaluated. Forty-five consecutive VMAT plans were analyzed retrospectively for treatment sites of the prostate, head and neck (HN), and other parts. The mean values of the metrics for proximal MLC and distal MLC were 0.310 and 0.245 (MCS), 71.09 cm(2)and 55.92 cm(2)(PA), 6.24 and 10.19 (PI), and 0.593 and 0.645 (PM), respectively. The degree of plan complexity in the distal MLC was larger than in the proximal MLC. The percentage of the effective distal MLC was higher than that of the proximal MLC (mean EDS = 0.555). The MCSw, PA(w), PIw, and PM(w)showed significant differences between the prostate and HN groups like the PA(5), PI5, and PM5; however, the MCS(5)did not. Additionally, the MCS(5)correlated with MU and PM5, while the MCS(w)correlated with SAS and PA(5). The plan complexity for each MLC layer and subsequently combining these complexities might be useful to better understand the dual-layer MLC performance.
引用
收藏
页码:947 / 957
页数:11
相关论文
共 50 条
  • [1] Plan complexity quantification of dual-layer multi-leaf collimator for volumetric modulated arc therapy with Halcyon linac
    Mikoto Tamura
    Kenji Matsumoto
    Masakazu Otsuka
    Hajime Monzen
    Physical and Engineering Sciences in Medicine, 2020, 43 : 947 - 957
  • [2] The Plan Complexity of VMAT for the Pelvic Region Of Halcyon Linac Using Dual-Layer Multi-Leaf Collimator
    Zhu, Q.
    Wang, Z.
    Yang, B.
    Liang, Y.
    Zhu, H.
    Zhang, W.
    Qiu, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E893 - E894
  • [3] Quantification of Treatment Plan Deliverability in Breast Volumetric-modulated Arc Therapy With Agility Multi-leaf Collimator
    Oh, Do Hoon
    Choi, Jin Hwa
    Ryu, Hyejo
    Chun, Minsoo
    IN VIVO, 2024, 38 (05): : 2254 - 2260
  • [4] Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri
    S. Panda
    J. Swamidas
    S. Chopra
    A. Mangaj
    A. Fogliata
    P. Kupelian
    J. P. Agarwal
    L. Cozzi
    Radiation Oncology, 15
  • [5] Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri
    Panda, S.
    Swamidas, J.
    Chopra, S.
    Mangaj, A.
    Fogliata, A.
    Kupelian, P.
    Agarwal, J. P.
    Cozzi, L.
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [6] Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy
    Oliver, Mike
    Gagne, Isabelle
    Bush, Karl
    Zavgorodni, Sergei
    Ansbacher, Will
    Beckham, Wayne
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 554 - 560
  • [7] Analysis of Multi-Leaf Collimator Leaf Position Errors in Volumetric Modulated Arc Therapy for Nasopharyngeal Carcinoma
    Li, C.
    Yin, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3514 - 3514
  • [8] Effect of treatment planning system parameters on beam modulation complexity for treatment plans with single-layer multi-leaf collimator and dual-layer stacked multi-leaf collimator
    Quintero, Paulo
    Cheng, Yongqiang
    Benoit, David
    Moore, Craig
    Beavis, Andrew
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1122):
  • [9] Dynamic Accuracy and Stability of Novel Multi-Leaf Collimator (MLC) for Volumetric Modulated Arc Therapy (VMAT)
    Nakaguchi, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3412 - 3412
  • [10] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Sasaki, Motoharu
    Tominaga, Masahide
    Kamomae, Takeshi
    Ikushima, Hitoshi
    Kitaoka, Motonori
    Bando, Ryota
    Sakuragawa, Kanako
    Oita, Masataka
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (09) : 511 - 525