Carr-Purcell sequences with composite pulses

被引:36
|
作者
Hürlimann, MD [1 ]
机构
[1] Schlumberger Doll Res Ctr, Ridgefield, CT 06877 USA
关键词
composite pulses; inhomogeneous fields; CPMG; relaxation;
D O I
10.1006/jmre.2001.2370
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present novel Carr-Purcell-like sequences using composite pulses that exhibit improved performance in strongly inhomogeneous fields. The sequences are designed to retain the intrinsic error correction of the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. This is achieved by matching the excitation pulse with the refocusing cycle such that the initial transverse magnetization lies along the axis (n) over cap (B) characterizing the overall rotation of the refocusing cycle. Such sequences are suitable for relaxation measurements. It is shown that in sufficiently inhomogeneous fields, the echo amplitudes have an initial transient modulation that is limited to the first few echoes and then decay with the intrinsic relaxation time of the sample. We show different examples of such sequences that are constructed from simple composite pulses. Sequences of the form 90(0)degrees-(90(90 degrees-theta /2)-theta (180-theta /2)-(90 degrees)(90-theta /2))(n) with theta approximate to 90 degrees and 270 degrees genera0 ate signal over a bandwidth larger than that of the conventional CPMG sequence, resulting in an improved signal-to-noise ratio in inhomogeneous fields. The new sequence 127(x,y)degrees-(127(x)degrees -127(-x)degrees)(n) only excites signal off-resonance with a spectrum that is bimodal, peaking at Deltaw(0) = +/- w(1). Depending on the phase and exact timing to the first pulse, symmetric or antisymmetric excitation is obtained. We also demonstrate several new sequences with improved dependence on the RIF field strength. The sequence (22.5(67,5)degrees -90 degrees-(22.5))- depends on B-1, allowing coarse B-1 imaging in a one-dimensional experiment. (C) 2001 Academic Press.
引用
收藏
页码:109 / 123
页数:15
相关论文
共 50 条
  • [41] Illustration of inversion-recovery and Carr-Purcell-Meiboom-Gill sequences by the determination of ethanol content in alcoholic beverages
    Gossuin, Yves
    Vuong, Quoc L.
    Grunin, Leonid
    Van Nedervelde, Laurence
    Pietercelie, Anne
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2017, 46A (03)
  • [42] Acute cerebral ischemia in rats studied by Carr-Purcell spin-echo magnetic resonance imaging:: Assessment of blood oxygenation level-dependent and tissue effects on the transverse relaxation
    Kavec, M
    Gröhn, OHJ
    Kettunen, MI
    Silvennoinen, MJ
    Garwood, M
    Kauppinen, RA
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1138 - 1146
  • [43] Optimization of timing in the Carr-Purcell-Meiboom-Gill sequence
    Hürlimann, MD
    MAGNETIC RESONANCE IMAGING, 2001, 19 (3-4) : 375 - 378
  • [44] Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T
    Michaeli, S
    Garwood, M
    Zhu, XH
    DelaBarre, L
    Andersen, P
    Adriany, G
    Merkle, H
    Ugurbil, K
    Chen, W
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) : 629 - 633
  • [45] High-Fidelity Adiabatic Passage by Composite Sequences of Chirped Pulses
    Torosov, Boyan T.
    Guerin, Stephane
    Vitanov, Nikolay V.
    PHYSICAL REVIEW LETTERS, 2011, 106 (23)
  • [46] Comparison of electron spin relaxation times measured by Carr-Purcell-Meiboom-Gill and two-pulse spin-echo sequences
    Harbridge, JR
    Eaton, SS
    Eaton, GR
    JOURNAL OF MAGNETIC RESONANCE, 2003, 164 (01) : 44 - 53
  • [47] Improved J-compensated sequences based on short composite pulses
    Torres, A. M.
    Bubb, W. A.
    Philp, D. J.
    Kuchel, P. W.
    JOURNAL OF MAGNETIC RESONANCE, 2008, 194 (01) : 81 - 88
  • [48] BASELINE DRIFT IN CARR-PURCELL-MEIBOOM-GILL PULSED NMR EXPERIMENT
    HUGHES, DG
    LINDBLOM, G
    JOURNAL OF MAGNETIC RESONANCE, 1974, 13 (01) : 142 - 147
  • [49] BASELINE DRIFT IN CARR-PURCELL-MEIBOOM-GILL PULSED NMR EXPERIMENT
    HUGHES, DG
    LINDBLOM, G
    JOURNAL OF MAGNETIC RESONANCE, 1977, 26 (03) : 469 - 479
  • [50] In vivo 1H2O T2† measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI:: Detection of microscopic susceptibility contrast
    Bartha, R
    Michaeli, S
    Merkle, H
    Adriany, G
    Andersen, P
    Chen, W
    Ugurbil, K
    Garwood, M
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) : 742 - 750