Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite

被引:41
|
作者
Adeloju, SB [1 ]
Barisci, JN [1 ]
Wallace, GG [1 ]
机构
[1] UNIV WOLLONGONG,DEPT CHEM,INTELLIGENT POLYMER RES LAB,WOLLONGONG,NSW 2522,AUSTRALIA
基金
澳大利亚研究理事会;
关键词
sulphite oxidase; polypyrrole; immobilisation; characterisation; amperometry;
D O I
10.1016/0003-2670(96)00261-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The immobilisation of sulphite oxidase into a polypyrrole him by galvanostatic polymerisation has been investigated. The properties of the film were characterised by radiolabelling technique, cyclic voltammetry, resistometry, electrochemical quartz crystal microbalance, scanning electron microscopy and atomic force microscopy. The radiolabelling measurements revealed that the amount of enzyme incorporated into the polypyrrole film is influenced by the enzyme concentration, film thickness and current density. The interaction of sulphite with the immobilised enzyme was confirmed by cyclic voltammetry, resistometry and electrochemical quartz crystal microbalance. Quantification of sulphite can be made from the amperometric response resulting from this interaction by flow injection analysis.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [41] Development of an amperometric biosensor that can determine the amount of glucose in the blood using the glucose oxidase enzyme: Preparation of polyaniline-polypyrrole-poly(sodium-4-styrenesulfonate) film
    Uzumer, Tugce Yagmur
    Cete, Servet
    Tekeli, Yener
    Altuner, Elif Esra
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2024, 71 (06) : 1440 - 1452
  • [42] Double Modification of Electrode Surface for the Selective Detection of Epinephrine and Its Application to Flow Injection Amperometric Analysis
    Xu, Guang-Ri
    Qi, Xin-hua
    Yang, Fengxia
    Lee, Jae-Joon
    Xu, Ming-Lu
    Zhang, Yu-Ping
    Kim, Sunghyun
    ELECTROANALYSIS, 2009, 21 (22) : 2486 - 2490
  • [43] Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis
    Andreas Rose
    Frieder W. Scheller
    U. Wollenberger
    Dorothea Pfeiffer
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 145 - 152
  • [44] Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis
    Rose, A
    Scheller, FW
    Wollenberger, U
    Pfeiffer, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (02): : 145 - 152
  • [45] Porous polypyrrole/polymethylmethacrylate composite film prepared by vapor deposition polymerization of pyrrole and its application for ammonia detection
    Han, Gaoyi
    Shi, Gaoquan
    THIN SOLID FILMS, 2007, 515 (17) : 6986 - 6991
  • [46] Evaluation of a nitrogen-incorporated tetrahedral amorphous carbon thin film for the detection of tryptophan and tyrosine using flow injection analysis with amperometric detection
    Jarosova, Romana
    Rutherford, Joy
    Swain, Greg M.
    ANALYST, 2016, 141 (21) : 6031 - 6041
  • [47] Determination of choline in milk, milk powder, and soy lecithin hydrolysates by flow injection analysis and amperometric detection with a choline oxidase based biosensor
    Pati, S
    Quinto, M
    Palmisano, F
    Zambonin, PG
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (15) : 4638 - 4642
  • [48] Flow injection analysis system based on amperometric thin-film transducers for free chlorine detection in swimming pool waters
    Olive-Monllau, Rosa
    Orozco, Jahir
    Fernandez-Sanchez, Cesar
    Baeza, Mireia
    Bartroli, Jordi
    Jimenez-Jorquera, Cecilia
    Cespedes, Francisco
    TALANTA, 2009, 77 (05) : 1739 - 1744
  • [49] Flow injection amperometric detection of adrenaline with thin film boron-doped diamond electrodes: Influence of doping time on performance
    Shabgahi, Ramtin Eghbal
    Pasquarelli, Alberto
    Wild, Michael
    Minkow, Alexander
    Kissinger, Dietmar
    DIAMOND AND RELATED MATERIALS, 2025, 153
  • [50] Comparison of Cobalt Hexacyanoferrate and Poly(Neutral Red) Modified Carbon Film Electrodes for the Amperometric Detection of Heavy Metals Based on Glucose Oxidase Enzyme Inhibition
    Attar, Aisha
    Ghica, M. Emilia
    Amine, Aziz
    Brett, Christopher M. A.
    ANALYTICAL LETTERS, 2015, 48 (04) : 659 - 671