Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite

被引:41
|
作者
Adeloju, SB [1 ]
Barisci, JN [1 ]
Wallace, GG [1 ]
机构
[1] UNIV WOLLONGONG,DEPT CHEM,INTELLIGENT POLYMER RES LAB,WOLLONGONG,NSW 2522,AUSTRALIA
基金
澳大利亚研究理事会;
关键词
sulphite oxidase; polypyrrole; immobilisation; characterisation; amperometry;
D O I
10.1016/0003-2670(96)00261-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The immobilisation of sulphite oxidase into a polypyrrole him by galvanostatic polymerisation has been investigated. The properties of the film were characterised by radiolabelling technique, cyclic voltammetry, resistometry, electrochemical quartz crystal microbalance, scanning electron microscopy and atomic force microscopy. The radiolabelling measurements revealed that the amount of enzyme incorporated into the polypyrrole film is influenced by the enzyme concentration, film thickness and current density. The interaction of sulphite with the immobilised enzyme was confirmed by cyclic voltammetry, resistometry and electrochemical quartz crystal microbalance. Quantification of sulphite can be made from the amperometric response resulting from this interaction by flow injection analysis.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [1] Electroimmobilization of MAO into a polypyrrole film and its utilization for amperometric flow detection of antidepressant drugs
    Vela, MH
    de Jesus, DS
    Couto, CMCM
    Araújo, AN
    Montenegro, MCBSM
    ELECTROANALYSIS, 2003, 15 (02) : 133 - 138
  • [2] Use of a copper electrode in alkaline medium as an amperometric sensor for sulphite in a flow-through configuration
    Corbo, D
    Bertotti, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) : 416 - 420
  • [3] Use of a copper electrode in alkaline medium as an amperometric sensor for sulphite in a flow-through configuration
    Dennys Corbo
    Mauro Bertotti
    Analytical and Bioanalytical Chemistry, 2002, 374 : 416 - 420
  • [4] Determination of sulphite using an immobilized enzyme with flow injection chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Waseem, A
    Masoom-Yasinzai, M
    LUMINESCENCE, 2004, 19 (01) : 26 - 30
  • [5] An amperometric biosensor for fish freshness detection from xanthine oxidase immobilized in polypyrrole-polyvinylsulphonate film
    Dolmaci, Nezaket
    Cete, Servet
    Arslan, Fatma
    Yasar, Ahmet
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (04): : 275 - 279
  • [6] Fast and reliable analyses of sulphite in fruit juices using a supramolecular amperometric detector encompassing in flow gas diffusion unit
    Martins, Paulo R.
    Popolim, Welliton D.
    Nagato, Leticia A. F.
    Takemoto, Emy
    Araki, Koiti
    Toma, Henrique E.
    Angnes, Lucio
    Penteado, Marilene De V. C.
    FOOD CHEMISTRY, 2011, 127 (01) : 249 - 255
  • [7] An amperometric biosensor for xanthine determination prepared from xanthine oxidase immobilized in polypyrrole film
    Arslan, F
    Yasar, A
    Kiliç, E
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (01): : 113 - 128
  • [8] Determination of formaldehyde by flow injection analysis with spectrophotometric detection exploiting brilliant green-sulphite reaction
    Lúcio Bolognesi
    Eder J. dos Santos
    Gilberto Abate
    Chemical Papers, 2015, 69 : 791 - 798
  • [9] Determination of formaldehyde by flow injection analysis with spectrophotometric detection exploiting brilliant green-sulphite reaction
    Bolognesi, Lucio
    dos Santos, Eder J.
    Abate, Gilberto
    CHEMICAL PAPERS, 2015, 69 (06) : 791 - 798
  • [10] Determination of sulphite in wines by gas-diffusion flow injection analysis utilizing spectrophotometric pH-detection
    DecnopWeever, LG
    Kraak, JC
    ANALYTICA CHIMICA ACTA, 1997, 337 (02) : 125 - 131