A sensitive and accurate fluorescent genosensor for Staphylococcus aureus detection

被引:25
|
作者
Liu, Rui [1 ]
Haruna, Suleiman A. [1 ]
Ali, Shujat [2 ]
Xu, Jing [1 ]
Zhang, Yunlian [1 ]
Lu, Peng [3 ]
Li, Huanhuan [1 ]
Chen, Quansheng [1 ]
机构
[1] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Wenzhou Univ, Coll Elect & Elect Engn, Wenzhou 325035, Peoples R China
[3] Jiangsu Univ, Sch Life Sci, Zhenjiang 212013, Jiangsu, Peoples R China
关键词
Upconverting nanoparticles; Graphene oxide quantum dots; Fluorescent genosensor; Staphylococcus aureus; UP-CONVERSION NANOPARTICLES; GRAPHENE QUANTUM DOTS; APTASENSOR; EFFICIENT; FLUX;
D O I
10.1016/j.snb.2021.131311
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pathogenic bacteria, as a major cause of foodborne diseases, pose a serious threat to human health, which urges the development of sensitive and accurate detection methods. Herein, a fluorescent genosensor was designed for Staphylococcus aureus (S. aureus) detection based on fluorescent probes and graphene oxide quantum dots (GOQDs). The pi-pi stacking and hydrogen bond interactions between GOQDs and specific single-stranded DNA (ssDNA) of the fluorescent probes were exploited by the developed genosensor. The interactions brought the GOQDs to the surface of the fluorescent probes, quenching strong upconversion fluorescence. However, the hybridization of the recognition probes anchored on the fluorescent reporters with complementary nuc target obstructed the interactions, causing the fluorescence to gradually increase with the increasing concentration of complementary nuc target. Consequently, the target-specific sensor exhibited high sensitivity with a LOD of 0.98 x 10(-17) mol L-1 and a linear range from 1 x 10(-17) to 1 x 10(-11) mol L-1. Moreover, the genosensor was successfully applied for real sample analysis with excellent recoveries. Significantly, the sensor could be used for the detection of other pathogens in actual samples by replacing recognition probes and primers.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A sensitive electrochemical genosensor for highly specific detection of thalassemia gene
    Gholivand, Mohammad-Bagher
    Akbari, Arezoo
    BIOSENSORS & BIOELECTRONICS, 2019, 129 : 182 - 188
  • [22] Fluorescent Identification and Detection of Staphylococcus aureus with Carboxymethyl Chitosan/CdS Quantum Dots Bioconjugates
    Wang, Xiaohui
    Du, Yumin
    Li, Yan
    Li, Dong
    Sun, Runcang
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2011, 22 (14) : 1881 - 1893
  • [23] Staphylococcus aureus Detection by Fluorescent Silica Nanoparticles Modified with Metal-Dipicolylamine Complexes
    Kasai, Yuna
    Kobayashi, Hiroyuki
    Tsuchido, Yuji
    Hashimoto, Takeshi
    Kanzawa, Nobuyuki
    Hayashita, Takashi
    CHEMISTRY LETTERS, 2016, 45 (07) : 749 - 751
  • [24] Dot-blot amperometric genosensor for detecting a novel determinant of β-lactamase resistance in Staphylococcus aureus
    Pividori, MI
    Merkoçi, A
    Alegret, S
    ANALYST, 2001, 126 (09) : 1551 - 1557
  • [25] A combination of positive dielectrophoresis driven on-line enrichment and aptamer-fluorescent silica nanoparticle label for rapid and sensitive detection of Staphylococcus aureus
    Shangguan, Jingfang
    Li, Yuhong
    He, Dinggeng
    He, Xiaoxiao
    Wang, Kemin
    Zou, Zhen
    Shi, Hui
    ANALYST, 2015, 140 (13) : 4489 - 4497
  • [26] Fluorescent aptasensor for highly sensitive detection of Staphylococcus aureus based on dual-amplification strategy by integrating DNA walking and hybridization chain reaction
    Zhang, Jialin
    Mao, Biyao
    Fan, Yaqi
    Zhou, Ming
    Wen, Herui
    Huang, Bin
    Lu, Kangqiang
    Ren, Jiali
    TALANTA, 2024, 270
  • [27] Detection and identification of methicillin resistant and sensitive strains of Staphylococcus aureus using tandem measurements
    Guntupalli, Rajesh
    Sorokulova, Iryna
    Olsen, Eric
    Globa, Ludmila
    Pustovyy, Oleg
    Moore, Timothy
    Chin, Bryan
    Barbaree, James
    Vodyanoy, Vitaly
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 90 (03) : 182 - 191
  • [28] A SENSITIVE ASSAY FOR STAPHYLOCOCCUS-AUREUS NUCLEASES
    KOHLI, JK
    VAKIL, BV
    PATIL, MS
    PANDEY, VN
    PRADHAN, DS
    INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1989, 26 (05): : 296 - 300
  • [29] Treatment of Penicillin-sensitive Staphylococcus aureus
    Beier, Frank
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2016, 141 (10)
  • [30] Multiple amplification-based fluorometric aptasensor for highly sensitive detection of Staphylococcus aureus
    Chen, Wei
    Zhang, Yanke
    Lai, Qingteng
    Li, Youzhen
    Liu, Zhengchun
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2022, 106 (19-20) : 6733 - 6743