A sensitive and accurate fluorescent genosensor for Staphylococcus aureus detection

被引:25
|
作者
Liu, Rui [1 ]
Haruna, Suleiman A. [1 ]
Ali, Shujat [2 ]
Xu, Jing [1 ]
Zhang, Yunlian [1 ]
Lu, Peng [3 ]
Li, Huanhuan [1 ]
Chen, Quansheng [1 ]
机构
[1] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Wenzhou Univ, Coll Elect & Elect Engn, Wenzhou 325035, Peoples R China
[3] Jiangsu Univ, Sch Life Sci, Zhenjiang 212013, Jiangsu, Peoples R China
关键词
Upconverting nanoparticles; Graphene oxide quantum dots; Fluorescent genosensor; Staphylococcus aureus; UP-CONVERSION NANOPARTICLES; GRAPHENE QUANTUM DOTS; APTASENSOR; EFFICIENT; FLUX;
D O I
10.1016/j.snb.2021.131311
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pathogenic bacteria, as a major cause of foodborne diseases, pose a serious threat to human health, which urges the development of sensitive and accurate detection methods. Herein, a fluorescent genosensor was designed for Staphylococcus aureus (S. aureus) detection based on fluorescent probes and graphene oxide quantum dots (GOQDs). The pi-pi stacking and hydrogen bond interactions between GOQDs and specific single-stranded DNA (ssDNA) of the fluorescent probes were exploited by the developed genosensor. The interactions brought the GOQDs to the surface of the fluorescent probes, quenching strong upconversion fluorescence. However, the hybridization of the recognition probes anchored on the fluorescent reporters with complementary nuc target obstructed the interactions, causing the fluorescence to gradually increase with the increasing concentration of complementary nuc target. Consequently, the target-specific sensor exhibited high sensitivity with a LOD of 0.98 x 10(-17) mol L-1 and a linear range from 1 x 10(-17) to 1 x 10(-11) mol L-1. Moreover, the genosensor was successfully applied for real sample analysis with excellent recoveries. Significantly, the sensor could be used for the detection of other pathogens in actual samples by replacing recognition probes and primers.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Sensitive fluorescent detection of Staphylococcus aureus using nanogold linked CdTe nanocrystals as signal amplification labels
    Tinging Miao
    Zhouping Wang
    Shuang Li
    Xin Wang
    Microchimica Acta, 2011, 172 : 431 - 437
  • [2] Sensitive fluorescent detection of Staphylococcus aureus using nanogold linked CdTe nanocrystals as signal amplification labels
    Miao, Tinging
    Wang, Zhouping
    Li, Shuang
    Wang, Xin
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 431 - 437
  • [3] Biosensors for rapid and sensitive detection of Staphylococcus aureus in food
    Rubab, Momna
    Shahbaz, Hafiz Muhammad
    Olaimat, Amin N.
    Oh, Deog-Hwan
    BIOSENSORS & BIOELECTRONICS, 2018, 105 : 49 - 57
  • [4] Navigable DNA walker coupled with exonucleases-assisted signal amplification for sensitive fluorescent detection of Staphylococcus aureus
    Cai, Rongfeng
    Chen, Xin
    Zhang, Yuting
    Wang, Xiaoli
    Zhou, Nandi
    Xia, Xiaole
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 394
  • [5] Fluorescent reporters for Staphylococcus aureus
    Malone, Cheryl L.
    Boles, Blaise R.
    Lauderdale, Katherine J.
    Thoendel, Matthew
    Kavanaugh, Jeffrey S.
    Horswill, Alexander R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 77 (03) : 251 - 260
  • [6] Recent Advances in Aptasensors For Rapid and Sensitive Detection of Staphylococcus Aureus
    Chen, Wei
    Lai, Qingteng
    Zhang, Yanke
    Liu, Zhengchun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [7] Detection of Staphylococcus aureus by a sensitive immuno-PCR assay
    Huang, SH
    Chang, TC
    CLINICAL CHEMISTRY, 2004, 50 (09) : 1673 - 1674
  • [8] Recent Advances in Aptasensors For Rapid and Sensitive Detection of Staphylococcus Aureus
    Chen, Wei
    Lai, Qingteng
    Zhang, Yanke
    Liu, Zhengchun
    Frontiers in Bioengineering and Biotechnology, 2022, 10
  • [9] Tapered Microfiber MZI Biosensor for Highly Sensitive Detection of Staphylococcus Aureus
    Li, Hou-Chang
    Leng, Yuan-Kui
    Liao, Yun-Cheng
    Liu, Bin
    Luo, Wei
    Liu, Juan
    Shi, Jiu-Lin
    Yuan, Jinhui
    Xu, Heng-Yi
    Xiong, Yong-Hua
    He, Xing-Dao
    Wu, Qiang
    IEEE SENSORS JOURNAL, 2022, 22 (06) : 5531 - 5539
  • [10] Highly Sensitive Detection of Staphylococcus aureus Directly from Patient Blood
    Banada, Padmapriya P.
    Chakravorty, Soumitesh
    Shah, Darshini
    Burday, Michele
    Mazzella, Fermina M.
    Alland, David
    PLOS ONE, 2012, 7 (02):