Characterization of a Time-Resolved Diffuse Optical Spectroscopy Prototype Using Low-Cost, Compact Single Photon Avalanche Detectors for Tissue Optics Applications

被引:7
|
作者
Alayed, Mrwan [1 ,2 ]
Palubiak, Darek P. [3 ]
Deen, M. Jamal [1 ,3 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON L8S 4L8, Canada
[2] King Abdul Aziz City Sci & Technol KACST, Natl Nanotechnol Ctr, Riyadh 11442, Saudi Arabia
[3] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
diffuse optical spectroscopy; time-resolved spectroscopy; tissue optics; single-photon avalanche diode; silicon photodetectors; time-correlated single-photon counting; SILICON PHOTOMULTIPLIER; REFLECTANCE; TOMOGRAPHY; SYSTEM; TRANSMITTANCE; SCATTERING; MIGRATION; ACCURACY;
D O I
10.3390/s18113680
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-resolved diffuse optical spectroscopy (TR-DOS) is an increasingly used method to determine the optical properties of diffusive media, particularly for medical applications including functional brain, breast and muscle measurements. For medical imaging applications, important features of new generation TR-DOS systems are low-cost, small size and efficient inverse modeling. To address the issues of low-cost, compact size and high integration capabilities, we have developed free-running (FR) single-photon avalanche diodes (SPADs) using 130 nm silicon complementary metal-oxide-semiconductor (CMOS) technology and used it in a TR-DOS prototype. This prototype was validated using assessments from two known protocols for evaluating TR-DOS systems for tissue optics applications. Following the basic instrumental performance protocol, our prototype had sub-nanosecond total instrument response function and low differential non-linearity of a few percent. Also, using light with optical power lower than the maximum permissible exposure for human skin, this prototype can acquire raw data in reflectance geometry for phantoms with optical properties similar to human tissues. Following the MEDPHOT protocol, the absolute values of the optical properties for several homogeneous phantoms were retrieved with good accuracy and linearity using a best-fitting model based on the Levenberg-Marquardt method. Overall, the results of this study show that our silicon CMOS-based SPAD detectors can be used to build a multichannel TR-DOS prototype. Also, real-time functional monitoring of human tissue such as muscles, breasts and newborn heads will be possible by integrating this detector with a time-to-digital converter (TDC).
引用
下载
收藏
页数:18
相关论文
共 23 条
  • [21] Low-Cost Compact Optical Spectroscopy and Novel Spectroscopic Algorithm for Point-of-Care Real-Time Monitoring of Nanoparticle Delivery in Biological Tissue Models
    Hasan, Md Zahid
    Yan, Jing
    Yi, Zhongchao
    Korfhage, Madison O.
    Tong, Sheng
    Zhu, Caigang
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2023, 29 (04)
  • [22] Characterization of single fungal aerosol particles in a reactive atmospheric environment using time-resolved optical trapping-Raman spectroscopy (OT-RS)
    Ai, Yukai
    Wang, Chuji
    Pan, Yong-Le
    Videen, Gorden
    ENVIRONMENTAL SCIENCE-ATMOSPHERES, 2022, 2 (04): : 591 - 600
  • [23] Optimal arrangements of fiber optic probes to enhance the spatial resolution in depth for 3D reflectance diffuse optical tomography with time-resolved measurements performed with fast-gated single-photon avalanche diodes
    Puszka, Agathe
    Di Sieno, Laura
    Dalla Mora, Alberto
    Pifferi, Antonio
    Contini, Davide
    Boso, Gianluca
    Tosi, Alberto
    Herve, Lionel
    Planat-Chretien, Anne
    Koenig, Anne
    Dinten, Jean-Marc
    MULTIMODAL BIOMEDICAL IMAGING IX, 2014, 8937