Evaluation of the Abbott realtime Ct/Ng assay using the M2000 system and comparison with the GenProbe Aptima Combo 2 assay

被引:0
|
作者
Quigley, D. I. [1 ]
Ellefson, A. [1 ]
Steed, L. L. [1 ]
Wolff, D. J. [1 ]
机构
[1] Med Univ S Carolina, Dept Pathol & Lab Med, Charleston, SC 29425 USA
来源
JOURNAL OF MOLECULAR DIAGNOSTICS | 2007年 / 9卷 / 05期
关键词
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
引用
收藏
页码:680 / 680
页数:1
相关论文
共 50 条
  • [1] Abbott Realtime HBV Assay Using the Abbott m2000 Instrument System
    Pabich, E.
    Mullen, C.
    Rhoads, J.
    Riesing, K.
    Alexander, H.
    Williams, M.
    Miller, T.
    Shaligram, C.
    Sachs, K.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2010, 12 (06): : 888 - 888
  • [2] Evaluation of the Abbott RealTime CT/NG Assay in Comparison to the Roche Cobas Amplicor CT/NG Assay
    Cheng, Annie
    Qian, Qinfang
    Kirby, James E.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) : 1294 - 1300
  • [3] Comparison of the Abbott m2000 RealTime CT Assay and the Cepheid GeneXpert CT/NG Assay to the Roche Amplicor CT Assay for Detection of Chlamydia trachomatis in Ocular Samples from Tanzania
    Dize, Laura
    West, Sheila
    Williams, James A.
    Van der Pol, Barbara
    Quinn, Thomas C.
    Gaydos, Charlotte A.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (05) : 1611 - 1613
  • [4] COMPARISON OF THE ABBOTT M2000 REALTIME CT ASSAY FOR CHLAMYDIA TRACHOMATIS MONITORING IN TANZANIA COMPARED TO THE ROCHE AMPLICOR CT ASSAY
    Agreda, P.
    Dize, L.
    West, S.
    Williams, J. A.
    Van der Pol, B.
    Gaydos, C. A.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A272 - A272
  • [5] Evaluation of the Aptima HBV Quant Assay Compared to Abbott RealTime M2000 HBV Quant Assay and Procleix Ultrio Plus dHBV Assay in Plasma Samples
    Yan, Ying
    Chang, Le
    Ji, Huimin
    Han, Yang
    Wang, Lunan
    [J]. MICROBIOLOGY SPECTRUM, 2022, 10 (04):
  • [6] Comparison of the Abbott m2000 and the Gen-Probe Aptima Combo2 system for STD testing
    Kronquist, K.
    Brimhall, B.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 680 - 680
  • [7] Evaluation of pooled ocular and vaginal swabs by the Cepheid GeneXpert CT/NG assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae compared to the GenProbe Aptima Combo 2 Assay
    Dize, L.
    West, S. K.
    Mkocha, H.
    Quinn, T. C.
    Gaydos, C. A.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 81 (02) : 102 - 104
  • [8] MEASUREMENT OF HCV RNA FROM DRIED BLOOD SPOTS USING THE ABBOTT M2000 SYSTEM AND ABBOTT REALTIME HCV ASSAY
    Cloherty, Gavin
    Lucic, Danijela
    Young, Thomas P.
    Riesing, Susan
    Pabich, Edward
    Sanborn, Mark R.
    [J]. HEPATOLOGY, 2010, 52 (04) : 1235A - 1235A
  • [9] Comparison of analytical performances of the Roche Cobas 6800 CT/NG assay with the Abbott m2000 Real Time CT/NG assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Cherkaoui, Abdessalam
    Renzi, Gesuele
    Mombelli, Michele
    Jaton, Katia
    Yerly, Sabine
    Vuilleumier, Nicolas
    Schrenzel, Jacques
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2019, 68 (02) : 197 - 200
  • [10] Quantification of CMV Using the m2000 RealTime CMV Assay
    Johnston, M. A.
    Allen, S. F.
    Steinmetz, H. B.
    Tsongalis, G. J.
    Lefferts, J. A.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2018, 20 (06): : 951 - 951