Energy dependence of pMOS dosemeters

被引:8
|
作者
Savic, Z
Stankovic, S
Kovacevic, M
Petrovic, M
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031575
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using Co-60 and Cs-137 sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 50 条
  • [1] ENERGY DEPENDENCE OF LITHIUM FLUORIDE DOSEMETERS AT HIGH ENERGIES
    CROSBY, EH
    ALMOND, PR
    SHALEK, RJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 131 - &
  • [2] ENERGY DEPENDENCE OF LITHIUM FLUORIDE DOSEMETERS AND HIGH ELECTRON ENERGIES
    PINKERTON, AP
    HOLT, JG
    LAUGHLIN, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 129 - +
  • [3] ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY
    Silva, E. H.
    Knezevic, Z.
    Struelens, L.
    Covens, P.
    Ueno, S.
    Vanhavere, F.
    Buls, N.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 208 - 212
  • [4] Systematic errors in the readings of trace etch neutron dosemeters caused by the energy dependence of response
    Tanner, RJ
    Thomas, DJ
    Bartlett, DT
    Horwood, N
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 483 - 486
  • [5] Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response
    Tanner, R.J.
    Thomas, D.J.
    Bartlett, D.T.
    Horwood, N.
    Radiation Measurements, 1999, 31 (01): : 483 - 486
  • [6] Let dependence of high sensitivity TL dosemeters
    Osvay, M
    Ranogajec-Komor, M
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 219 - 222
  • [7] Response of pMOS dosemeters on gamma-ray irradiation during its re-use
    Pejovic, Milic M.
    Pejovic, Momcilo M.
    Jaksic, Aleksandar B.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (04) : 394 - 403
  • [8] EFFECTS OF PACKAGE GEOMETRY, MATERIALS, AND DIE DESIGN ON ENERGY-DEPENDENCE OF PMOS DOSIMETERS
    BRUCKER, GJ
    KRONENBERG, S
    GENTNER, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (01) : 33 - 40
  • [9] Sensitivity and fading of pMOS dosemeters irradiated with X-ray radiation doses from 1 to 100 cGy
    Pejovic, Svetlana M.
    Pejovic, Milic M.
    Stojanov, Dragan
    Ciraj-Bjelac, Olivera
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 33 - 39
  • [10] ENERGY DEPENDENCE OF LITHIUM FLUORIDE DOSEMETERS AT ELECTRON ENERGIES FROM 10-MEV TO 35-MEV
    BINKS, C
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (02): : 327 - &