Reliability of measurements of energy expenditure and substrate oxidation using whole-room indirect calorimetry

被引:9
|
作者
Allerton, Timothy D. [1 ]
Carnero, Elvis A. [2 ]
Bock, Christopher [2 ]
Corbin, Karen D. [2 ]
Luyet, Pierre-Philippe [3 ]
Smith, Steven R. [2 ]
Ravussin, Eric [1 ]
机构
[1] Pennington Biomed Res Ctr, 6400 Perkins Rd, Baton Rouge, LA 70808 USA
[2] AdventHlth Translat Res Inst, Orlando, FL USA
[3] Sanofi, R&D Clin Sci & Operat, Frankfurt, Germany
关键词
FUEL UTILIZATION; METABOLIC-RATE; DETERMINANTS; OBESITY;
D O I
10.1002/oby.23226
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective This analysis aimed to measure the intraparticipant reliability-the intraclass correlation coefficient-of all the components of daily energy expenditure (EE) (24-hour EE, sleep EE, resting EE, basal EE, and thermic effect of food) over a period of 3 consecutive days in 35 study participants. Methods The components of daily EE and substrate use (respiratory exchange ratio) were measured over 3 consecutive days before and after a 3-week 1,000-kcal/d caloric restriction/weight-loss intervention. Results There was a high degree of reliability for sleep EE (96.8%), 24-hour EE (97.8%), basal EE (90.6%), and resting EE (93.2%) during the run-in period. The intraclass correlation coefficient for the follow-up period after weight loss (3.67 +/- 1.10 kg) remained high for sleep EE (95.6%), 24-hour EE (100%), basal EE (96.1%), and resting EE (92.5%). The minimal detectable differences in EE were reduced by 30% for both 24-hour EE and sleep EE when comparing 2 days versus 1 day spent in the whole-room indirect calorimeter. Conclusions The reliability of the daily components of EE is very high both prior to and after a weight-loss intervention. We here provide instrumental data for investigators to adequately power studies investigating energy metabolism using whole-room indirect calorimetry.
引用
收藏
页码:1508 / 1515
页数:8
相关论文
共 50 条
  • [31] Total energy expenditure assessed by 24-h whole-room indirect calorimeter in patients with colorectal cancer: baseline findings from the PRIMe study
    Ford, Katherine L.
    Pichard, Claude
    Sawyer, Michael B.
    Trottier, Claire F.
    Disi, Ilana Roitman
    Purcell, Sarah A.
    Ghosh, Sunita
    Siervo, Mario
    Deutz, Nicolaas E. P.
    Prado, Carla M.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2023, 118 (02): : 422 - 432
  • [32] Evaluation of accuracy and reliability of indirect calorimetry for the measurement of resting energy expenditure in healthy dogs
    O'Toole, E
    McDonell, WN
    Wilson, BA
    Mathews, KA
    Miller, CW
    Sears, WC
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (11) : 1761 - 1767
  • [33] Validation of the doubly labeled water method using integrated cavity output spectroscopy against isotope ratio mass spectrometry and whole-room indirect calorimetry
    Melanson, Edward L.
    Plasqui, Guy
    Wouters, Loek
    Kohrt, Wendy S.
    Swibas, Tracy
    Catenacci, Vicki A.
    Speakman, John R.
    Berman, Elena S.
    FASEB JOURNAL, 2016, 30
  • [34] Whole room indirect calorimetry 24hr substrate oxidation rates and changes in fat intake in college age subjects
    Smith, BK
    Hall, N
    Sullivan, D
    Donnelly, JE
    FASEB JOURNAL, 2005, 19 (05): : A1133 - A1133
  • [35] PROCEDURES FOR CALCULATING SUBSTRATE AND ENERGY BALANCES USING INDIRECT CALORIMETRY
    PRENTICE, AM
    MURGATROYD, PR
    HUMAN NUTRITION-CLINICAL NUTRITION, 1987, 41C (06): : 489 - 491
  • [36] REPEATABILITY OF 24-H ENERGY-EXPENDITURE MEASUREMENTS IN HUMANS BY INDIRECT CALORIMETRY
    RUMPLER, WV
    SEALE, JL
    CONWAY, JM
    MOE, PW
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (02): : 147 - 152
  • [37] REPEATABILITY OF ENERGY-EXPENDITURE MEASUREMENTS IN CLINICALLY NORMAL DOGS BY USE OF INDIRECT CALORIMETRY
    WALTERS, LM
    OGILVIE, GK
    SALMAN, MD
    JOY, L
    FETTMAN, MJ
    HAND, MS
    WHEELER, SL
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1993, 54 (11) : 1881 - 1885
  • [38] Sensitivity Analysis of Whole-Room Indirect Calorimeters at the Steady-State Condition
    Bandini, Gabriele
    Landi, Alberto
    Santini, Ferruccio
    Basolo, Alessio
    Marracci, Mirko
    Piaggi, Paolo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [39] Substrate utilization and energy expenditure pattern in sepsis by indirect calorimetry (vol 24, 535, 2020)
    Li, Andrew
    Mukhopadhyay, Amartya
    CRITICAL CARE, 2020, 24 (01)
  • [40] Indirect calorimetry: A fundamental tool to measure energy expenditure
    De Cristofaro, P
    Pietrobelli, A
    Dragani, B
    Malatesta, G
    Arzeni, S
    Luciani, M
    Malavolti, M
    Poli, M
    Battistini, N
    OBESITY RESEARCH, 2005, 13 : A54 - A54