The paper deals with mass transfer in liquid-liquid extraction in both directions using the following ternary systems, water-acetone-chloroform and water-acetone-toluene. The experiments were performed in an improved Lewis cell operating in continuous mode, made out of two baffled compartments equipped with separate driven agitators. Each compartment contains a stirred or non-stirred phase. The transfer of the solute can be carried in the two directions through an interface of constant area, created between the two phases. The specific resistances on mass transfer were determined in the stirred or non-stirred phases, with the influence of the partition coefficient and transfer direction on these resistances being also evidenced. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:909 / 916
页数:8
相关论文
共 50 条
  • [41] Mixing behavior and mass transfer of liquid-liquid two-phase flow in an annular microchannel with helical wires
    An, Min
    Wang, Chengxiang
    Liu, Qing
    Wang, Mengya
    Yang, Zhirong
    Li, Wenpeng
    Zhou, Guoli
    Wang, Jingtao
    Zhang, Jinli
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2025, 77 : 42 - 56
  • [42] Dispersed-phase mass transfer in agitated liquid-liquid systems
    Skelland, A.H.P.
    Xien, Hu
    Industrial and Engineering Chemistry Research, 1990, 29 (03): : 415 - 420
  • [43] Selection of mass transfer correlations for rate based liquid-liquid extraction model
    Sanpui, D
    Khanna, A
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (04) : 609 - 616
  • [44] Experimental investigation of the effects of surfactants on the mass transfer in liquid-liquid extraction equipment
    Haghdoost, A.
    Shah-Alami, M.
    Mansouri, H.
    FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B, 2007, : 239 - 244
  • [45] THE EFFECT OF PACKING SIZE AND COLUMN DIAMETER ON MASS TRANSFER IN LIQUID-LIQUID EXTRACTION
    LEIBSON, I
    BECKMANN, RB
    CHEMICAL ENGINEERING PROGRESS, 1953, 49 (08) : 405 - 416
  • [46] Mass Transfer from Nanofluid Single Drops in Liquid-Liquid Extraction Process
    Saien, Javad
    Bamdadi, Hamid
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (14) : 5157 - 5166
  • [47] Model assessment for the prediction of mass transfer coefficients in liquid-liquid extraction columns
    Outili, N.
    Meniai, A.-H.
    Gneist, G.
    Bart, H.-J.
    CHEMICAL ENGINEERING & TECHNOLOGY, 2007, 30 (06) : 758 - 763
  • [48] Mass transfer into/from nanofluid drops in a spray liquid-liquid extraction column
    Ashrafmansouri, Seyedeh-Saba
    Esfahany, Mohsen Nasr
    AICHE JOURNAL, 2016, 62 (03) : 852 - 860
  • [49] Single drop mass transfer in ternary and quaternary liquid-liquid extraction systems
    Brodkorb, MJ
    Bosse, D
    von Reden, C
    Gorak, A
    Slater, MJ
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2003, 42 (11) : 825 - 840
  • [50] Mass transfer from nanofluid drops in a pulsed liquid-liquid extraction column
    Bahmanyar, Amir
    Khoobi, Nafiseh
    Moharrer, Mostafa Mohammad Ali
    Bahmanyar, Hossein
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (11): : 2313 - 2323