Comparison of inverse dynamics calculated by two- and three-dimensional models during walking

被引:49
|
作者
Alkjaer, T
Simonsen, EB
Dyhre-Poulsen, F
机构
[1] Univ Copenhagen, Panum Inst, Dept Med Anat, Sect C, DK-2200 Copenhagen, Denmark
[2] Univ Copenhagen, Panum Inst, Dept Med Physiol, DK-2200 Copenhagen, Denmark
关键词
human locomotion; biomechanics; two- and three-dimensional analysis; walking; inverse dynamics;
D O I
10.1016/S0966-6362(00)00099-0
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of the study was to compare joint moments calculated by a two- (2D) and a three-dimensional (3D) inverse dynamics model to examine how the different approaches influenced the joint moment profiles. Fifteen healthy male subjects participated in the study. A five-camera video system recorded the subjects as they walked across two force plates, The subjects were invited to approach a walking speed of 4.5 km/h. The ankle, knee and hip joint moments in the sagittal plane were calculated by 2D and 3D inverse dynamics analysis and compared. Despite the uniform walking speed (4.53 km/h) and similar footwear, relatively large inter-individual variations were found in the joint moment patterns during the stance phase. The differences between individuals were present in both the 2D and 3D analysis. For the entire sample of subjects the overall time course pattern of the ankle, knee and hip joint moments was almost identical in 2D and 3D. However, statistically significant differences were observed in the magnitude of the moments, which could be explained by differences in the joint centre location and joint axes used in the two approaches. In conclusion, there were differences between the magnitude of the joint moments calculated by 2D and 3D inverse dynamics but the inter-individual variation was not affected by the different models. The simpler 2D model seems therefore appropriate for human gait analysis. However, comparisons of gait data from different studies are problematic if the calculations are based on different approaches. A future perspective for solving this problem could be to introduce a standard proposal for human gait analysis. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [41] A Comparison of Two- and Three-Dimensional Fracture Assessments in the Presence of Residual Stresses
    Lewis, S. J.
    Truman, C. E.
    Smith, D. J.
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2009, 131 (02):
  • [42] Comparison of diagnostic accuracies of two- and three-dimensional MR elastography of the liver
    Morisaka, Hiroyuki
    Motosugi, Utaroh
    Glaser, Kevin J.
    Ichikawa, Shintaro
    Ehman, Richard L.
    Sano, Katsuhiro
    Ichikawa, Tomoaki
    Onishi, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 1163 - 1170
  • [43] A comparison of turbulent flow over two- and three-dimensional sinusoidal topographies
    Calhoun, R
    Street, R
    12TH SYMPOSIUM ON BOUNDARY LAYERS AND TURBULENCE, 1997, : 528 - 529
  • [44] Comparison between two- and three-dimensional ultrasound in diagnosis of abdominal diseases
    Zhou, Yu-Qing
    Zhang, Qing-Ping
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [45] Comparison between two- and three-dimensional Rayleigh-Benard convection
    van der Poel, Erwin P.
    Stevens, Richard J. A. M.
    Lohse, Detlef
    JOURNAL OF FLUID MECHANICS, 2013, 736 : 177 - 194
  • [46] Intraoperative imaging of the shoulder: A comparison of two- and three-dimensional imaging techniques
    Suero, Eduardo M.
    Hawi, Nael
    Citak, Musa
    Decker, Sebastian
    Brandes, Julia
    Meller, Rupert
    Krettek, Christian
    Stuebig, Timo
    TECHNOLOGY AND HEALTH CARE, 2015, 23 (02) : 171 - 177
  • [47] Comparison of two- and three-dimensional finite element analyses of adhesive joints
    Richardson, G.
    Crocombe, A.D.
    Smith, P.A.
    International Journal of Adhesion and Adhesives, 1993, 13 (03): : 193 - 200
  • [48] A comparison of primary two- and three-dimensional methods to review CT colonography
    Rogier E. van Gelder
    Jasper Florie
    C. Yung Nio
    Sebastiaan Jensch
    Steven W. de Jager
    Frans M. Vos
    Henk W. Venema
    Joep F. Bartelsman
    Johannes B. Reitsma
    Patrick M. M. Bossuyt
    Johan S. Laméris
    Jaap Stoker
    European Radiology, 2007, 17 : 1181 - 1192
  • [49] A comparison of primary two- and three-dimensional methods to review CT colonography
    van Gelder, Rogier E.
    Florie, Jasper
    Nio, C. Yung
    Jensch, Sebastiaan
    de Jager, Steven W.
    Vos, Frans M.
    Venema, Henk W.
    Bartelsman, Joep F.
    Reitsma, Johannes B.
    Bossuyt, Patrick M. M.
    Lameris, Johan S.
    Stoker, Jaap
    EUROPEAN RADIOLOGY, 2007, 17 (05) : 1181 - 1192
  • [50] Comparison of ultrasonic attenuation within two- and three-dimensional polycrystalline media
    Bai, X.
    Tie, B.
    Schmitt, J-H
    Aubry, D.
    ULTRASONICS, 2020, 100 (100)