A stereotactic method for the three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology, and autoradiography

被引:49
|
作者
Humm, JL [1 ]
Ballon, D [1 ]
Hu, YC [1 ]
Ruan, S [1 ]
Chui, C [1 ]
Tulipano, PK [1 ]
Erdi, A [1 ]
Koutcher, J [1 ]
Zakian, K [1 ]
Urano, M [1 ]
Zanzonico, P [1 ]
Mattis, C [1 ]
Dyke, J [1 ]
Chen, Y [1 ]
Harrington, P [1 ]
O'Donoghue, JA [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys & Radiol, New York, NY 10021 USA
关键词
image registration; fiduciary markers; rodent imaging;
D O I
10.1118/1.1600738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this work was to develop and then validate a stereotactic fiduciary marker system for tumor xenografts in rodents which could be used to co-register magnetic resonance imaging (MRI), PET, tissue histology, autoradiography, and measurements from physiologic probes. A Teflon(TM) fiduciary template has been designed which allows the precise insertion of small hollow Teflon rods (0.71 mm diameter) into a tumor. These rods can be visualized by MRI and PET as well as by histology and autoradiography on tissue sections. The methodology has been applied and tested on a rigid phantom, on tissue phantom material, and finally on tumor bearing mice. Image registration has been performed between the MRI and PET images for the rigid Teflon phantom and among MRI, digitized microscopy images of tissue histology, and autoradiograms for both tissue phantom and tumor-bearing mice. A registration accuracy, expressed as the average Euclidean distance between the centers of three fiduciary markers among the registered image sets, of 0.2 +/-0.06 mm was achieved between MRI and microPET image sets of a rigid Teflon phantom. The fiduciary template allows digitized tissue sections to be co-registered with three-dimensional MRI images with an average accuracy of 0.21 and 0.25 mm for the tissue phantoms and tumor xenografts, respectively. Between histology and autoradiograms, it was 0.19 and 0.21 mm for tissue phantoms and tumor xenografts, respectively. The fiduciary marker system provides a coordinate system with which to correlate information from multiple image types, on a voxel-by-voxel basis, with sub-millimeter accuracy-even among imaging modalities with widely disparate spatial resolution and in the absence of identifiable anatomic landmarks. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2303 / 2314
页数:12
相关论文
共 31 条
  • [1] Three-dimensional reconstruction and fusion for multi-modality spinal images
    Chen, YT
    Wang, MS
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (1-2) : 21 - 31
  • [2] Multi-Modality fiducial marker for validation of registration of medical images with histology
    Shojaii, Rushin
    Martel, Anne L.
    [J]. MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [3] Multi-resolution three-dimensional multi-modality image registration by maximization of mutual information
    Ren, HP
    Yang, H
    Wu, WK
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2411 - 2413
  • [4] Application of three-dimensional voxel fusion technique to multi-modality fusion of anatomical and functional images
    Li, G
    Xie, H
    Ning, H
    Menard, C
    Coleman, CN
    Miller, RW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S582 - S582
  • [5] Three-dimensional registration of prostate images from histology and ultrasound
    Taylor, LS
    Porter, BC
    Nadasdy, G
    Di Sant'Agnese, PA
    Pasternack, D
    Wu, Z
    Baggs, RB
    Rubenst, DJ
    Parker, KJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02): : 161 - 168
  • [6] Three-Dimensional Multi-Modality Registration for Orthopaedics and Cardiovascular Settings: State-of-the-Art and Clinical Applications
    Garzia, Simone
    Capellini, Katia
    Gasparotti, Emanuele
    Pizzuto, Domenico
    Spinelli, Giuseppe
    Berti, Sergio
    Positano, Vincenzo
    Celi, Simona
    [J]. SENSORS, 2024, 24 (04)
  • [7] Broad-spectrum multi-modality image registration: From PET, CT, and MRI to autoradiography, microscopy, and beyond
    Zanzonico, Pat B.
    [J]. 2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 6372 - 6376
  • [8] A new automated method for three-dimensional registration of medical images
    Kotsas, P
    Strintzis, M
    Piraino, DW
    [J]. SIMULATIONS IN BIOMEDICINE IV, 1997, : 337 - 346
  • [9] A 3D Registration Method for US/PET Multi-Modality Small Animal Tumor Imaging
    Liao, Ai-Ho
    Chen, Li-Yen
    Cheng, Wen-Fang
    Li, Pai-Chi
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2214 - +
  • [10] A coarse-to-fine registration method for three-dimensional MR images
    Li, Cuixia
    Zhou, Yuanyuan
    Li, Yinghao
    Yang, Shanshan
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (02) : 457 - 469