Influence of Microwave Disinfection on the Dimensional Stability of Denture Reline Polymers

被引:13
|
作者
Manzolli Basso, Michael Frederico [1 ]
Giampaolo, Eunice Teresinha [1 ]
Vergani, Carlos Eduardo [1 ]
Machado, Ana Lucia [1 ]
Pavarina, Ana Claudia [1 ]
Ribeiro, Roberta Chuqui [1 ]
机构
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2010年 / 19卷 / 05期
基金
巴西圣保罗研究基金会;
关键词
Acrylic resin; polymer; complete denture; relining; microwave energy; RESIDUAL MONOMER CONTENT; DENTAL ACRYLIC RESIN; BASE MATERIALS; WATER; POLYMERIZATION; STERILIZATION; METHACRYLATE; RELEASE;
D O I
10.1111/j.1532-849X.2010.00583.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the effect of microwave disinfection (3 minutes at 650 W) on the dimensional stability of hard chairside reline resins (Kooliner, Tokuyama Rebase II, Ufi Gel hard, New Truliner) and one heat-polymerizing denture base resin (Lucitone 550). Materials and Methods: A split mold with reference points was used to make specimens (50.0-mm diameter, 0.5-mm thick) from each material, divided into five test groups (n = 8). The distances between the points on the mold were measured (gold standard), and compared with those obtained from the specimens after polymerization (baseline readings) after one, two, three, and four cycles of disinfection by microwave irradiation. Results: ANOVA and Tukey tests (alpha = 0.05) showed that Kooliner was significantly affected by all disinfection cycles (p < 0.05) when compared with baseline measurements. New Truliner resin was significantly affected by three and four cycles of microwave disinfection when compared with baseline measurements (p < 0.05). For Tokuyama Rebase II, Ufi Gel hard, and Lucitone 550, no significant dimensional changes were found. Conclusions: Microwave disinfection promoted shrinkage of Kooliner and New Truliner. The dimensional stability of Tokuyama Rebase II, Ufi Gel Hard, and Lucitone 550 was not affected by microwave disinfection.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [41] A critical review of protocols for conventional microwave oven use for denture disinfection
    Brondani, Mario A.
    Siqueira, Adriana R.
    COMMUNITY DENTAL HEALTH, 2018, 35 (04) : 228 - 234
  • [42] Effect of microwave disinfection on the bond strength of denture teeth to acrylic resins
    Ribeiro, Roberta Chuqui
    Giampaolo, Eunice Teresinha
    Machado, Ana Lucia
    Vergani, Carlos Eduardo
    Pavarina, Ana Cláudia
    International Journal of Adhesion and Adhesives, 2008, 28 (06): : 296 - 301
  • [43] Effect of microwave disinfection on the bond strength of denture teeth to acrylic resins
    Ribeiro, Roberta Chuqui
    Giampaolo, Eunice Teresinha
    Machado, Ana Lucia
    Vergani, Carlos Eduardo
    Pavarina, Ana Claudia
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2008, 28 (06) : 296 - 301
  • [44] Comparison of denture microwave disinfection and conventional antifungal therapy in the treatment of denture stomatitis: a randomized clinical study
    Silva, Mariana Montenegro
    de Oliveira Mima, Ewerton Garcia
    Colombo, Arnaldo Lopes
    Sanita, Paula Volpato
    Jorge, Janaina Habib
    Sgavioli Massucato, Elaine Maria
    Vergani, Carlos Eduardo
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (04): : 469 - 479
  • [45] Dimensional Stability of Elastomeric Impression Material After Disinfection Via Immersion and Microwave Irradiation
    Mohd, Noorhayati R.
    Omar, Ros A.
    Etajuri, Enas A.
    OPEN DENTISTRY JOURNAL, 2021, 15 : 658 - 663
  • [46] Indentation Size Effect in Autopolymerized and Microwave Post Treated Poly(methyl methacrylate) Denture Reline Resins
    Balosi, Sebastian
    Sidjanini, Leposava
    Pilic, Branka
    ACTA POLYTECHNICA HUNGARICA, 2014, 11 (07) : 239 - 249
  • [47] The influence of microwave irradiation on the hardness of two autopolymerizing reline resins.
    Reis, JMSN
    Vergani, CE
    Seo, RS
    Machado, AL
    Giampaolo, ET
    Pavarina, AC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 167 - 167
  • [48] Effect of Disinfection on the Bond Strength between Denture Teeth and Microwave-Cured Acrylic Resin Denture Base
    Matos, Adaias O.
    Costa, Josiane O.
    Beline, Thamara
    Ogawa, Erika S.
    Assuncao, Wirley G.
    Mesquita, Marcelo F.
    Consani, Rafael X.
    Barao, Valentim A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 169 - 176
  • [49] Effect of microwave disinfection on the vickers hardness of acrylic resin denture teeth.
    Campanha, NH
    Pavarina, AC
    Giampaolo, ET
    Vergani, CE
    Machado, AL
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 215 - 215
  • [50] Effect of Chemical and Microwave Disinfection on the Surface Microhardness of Acrylic Resin Denture Teeth
    Vasconcelos, Ligia Regina
    Xediek Consani, Rafael Leonardo
    Mesquita, Marcelo Ferraz
    Coelho Sinhoreti, Mario Alexandre
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (04): : 298 - 303