Influence of Microwave Disinfection on the Dimensional Stability of Denture Reline Polymers

被引:13
|
作者
Manzolli Basso, Michael Frederico [1 ]
Giampaolo, Eunice Teresinha [1 ]
Vergani, Carlos Eduardo [1 ]
Machado, Ana Lucia [1 ]
Pavarina, Ana Claudia [1 ]
Ribeiro, Roberta Chuqui [1 ]
机构
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Acrylic resin; polymer; complete denture; relining; microwave energy; RESIDUAL MONOMER CONTENT; DENTAL ACRYLIC RESIN; BASE MATERIALS; WATER; POLYMERIZATION; STERILIZATION; METHACRYLATE; RELEASE;
D O I
10.1111/j.1532-849X.2010.00583.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the effect of microwave disinfection (3 minutes at 650 W) on the dimensional stability of hard chairside reline resins (Kooliner, Tokuyama Rebase II, Ufi Gel hard, New Truliner) and one heat-polymerizing denture base resin (Lucitone 550). Materials and Methods: A split mold with reference points was used to make specimens (50.0-mm diameter, 0.5-mm thick) from each material, divided into five test groups (n = 8). The distances between the points on the mold were measured (gold standard), and compared with those obtained from the specimens after polymerization (baseline readings) after one, two, three, and four cycles of disinfection by microwave irradiation. Results: ANOVA and Tukey tests (alpha = 0.05) showed that Kooliner was significantly affected by all disinfection cycles (p < 0.05) when compared with baseline measurements. New Truliner resin was significantly affected by three and four cycles of microwave disinfection when compared with baseline measurements (p < 0.05). For Tokuyama Rebase II, Ufi Gel hard, and Lucitone 550, no significant dimensional changes were found. Conclusions: Microwave disinfection promoted shrinkage of Kooliner and New Truliner. The dimensional stability of Tokuyama Rebase II, Ufi Gel Hard, and Lucitone 550 was not affected by microwave disinfection.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [1] Influence of microwave disinfection on the dimensional stability of intact and relined acrylic resin denture bases
    Seo, Rosangela Seiko
    Vergani, Carlos Eduardo
    Pavarina, Ana Claudia
    Compagnoni, Marco Antonio
    Machado, Ana Lucia
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03): : 216 - 223
  • [2] Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
    Machado, Ana Lucia
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    de Souza, Juliana Feltrin
    Jorge, Janaina Habib
    JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (05) : 521 - 528
  • [3] Dimensional stability of hard chair-side reline resin after microwave disinfection.
    Perez, LEC
    Machado, AL
    Vergani, CE
    Pavarina, AC
    Giampaolo, ET
    Azevedo, A
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 163 - 163
  • [4] Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases
    Nirale, Rutuja Madhukarrao
    Thombre, Ram
    Kubasad, Girish
    JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (01): : 24 - 29
  • [5] Shear bond strength of denture reline polymers to denture base polymers
    Takahashi, Y
    Chai, J
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (03) : 271 - 275
  • [6] Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
    Machado, Ana Lucia
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    Jorge, Janaina Habib
    Vergani, Carlos Eduardo
    GERODONTOLOGY, 2012, 29 (02) : E375 - E382
  • [7] Effect of disinfection on adhesion of reline polymers
    Goncalves, Alessandro Ribeiro
    Machado, Ana Lucia
    Vergani, Carlos Eduardo
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    JOURNAL OF ADHESION, 2007, 83 (1-3): : 139 - 150
  • [8] Effect of disinfection by microwave irradiation on the strength of intact and relined denture bases and the water sorption and solubility of denture base and reline materials
    Seo, Rosangela Seiko
    Vergani, Carlos Eduardo
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    dos Santos Nunes Reis, Jose Mauricio
    Machado, Ana Lucia
    JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 107 (01) : 300 - 308
  • [9] Does microwave disinfection affect the dimensional stability of denture base acrylic resins? A systematic review
    da Costa, Rodrigo Moreira Bringel
    Venante, Helena Sandrini
    Pordeus, Mariana Domingues
    Chappuis-Chocano, Ana Paula
    Neppelenbroek, Karin Hermana
    Santiago Junior, Joel Ferreira
    Porto, Vinicius Carvalho
    GERODONTOLOGY, 2022, 39 (04) : 339 - 347
  • [10] Linear dimensional changes of denture base and hard chair-side reline resins after disinfection
    Goncalves, Alessandro Ribeiro
    Machado, Ana Lucia
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    Vergani, Carlos Eduardo
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 102 (02) : 1821 - 1826