Magnetic resonance angiography of the coronary arteries

被引:0
|
作者
Bruaire, JP [1 ]
Peretti, II [1 ]
Remond, A [1 ]
Dehouck, B [1 ]
机构
[1] HOP SUD,SERV REANIMAT CARDIAQUE,UNITE RECH IRM,AMIENS,FRANCE
来源
PRESSE MEDICALE | 1996年 / 25卷 / 21期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Evaluate magnetic resonance imaging of the coronary arteries. Methods: The study was conducted in 18 healthy volunteers (mean age 26 years, range 22-32). A superconducting magnet operating at 1.5 Tesla was used with an in-phase matrix surface coil. Images were obtained with 2D acquisition with flow compensation on ultra-rapid echo gradient sequences coupled with the electrocardiogram and segmentation of the Fourier plane. A coronary image was obtained during a 15 to 20 sec apnea. Frontal slices were used to identify cardiac structures before selecting axial slices starting from the origin of the aorta to the coronary ostia. Orthogonal, oblique and radial slices were then obtained starting from the axial slices. Slice thickness was 3 to 5 mm separated by 0.5 mm with a 30 degrees angle and a 320 mm field. Echo times were 5.8 and 10.3 msec with 2 excitations, Heart rate varied from 59 to 85 sec giving 15 to 18 ms repetition and 96 to 144 msec time resolution. Results: The proximal, middle and disatal segments of the right coronary artery were seen in 100% of the subjects, the common left coronary artery in 100%, the proximal anterior interventricular artery in 83% and the proximal circumflex artery in 80%. All the coronary arteries were visualized on at least two slices with different incidences. The proximal measurements were: common trunk 3.75 +/- 0.66 mm; anterior interventricular 3.25 +/- 0.43 mm; circumflex 2.62 +/- 0.48; right coronary 3.37 +/- 0.51. Conclusion: Magnetic resonance angiography provides good visualization of the coronary arteries.
引用
收藏
页码:967 / 972
页数:6
相关论文
共 50 条
  • [41] Automatic labeling of cerebral arteries in magnetic resonance angiography
    Dunas, Tora
    Wahlin, Anders
    Ambarki, Khalid
    Zarrinkoob, Laleh
    Birgander, Richard
    Malm, Jan
    Eklund, Anders
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (01) : 39 - 47
  • [42] Cardiovascular magnetic resonance of anomalous coronary arteries
    Varghese, A
    Keegan, J
    Pennell, DJ
    CORONARY ARTERY DISEASE, 2005, 16 (06) : 355 - 364
  • [43] MULTISLICE MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY
    HU, BS
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A89 - A89
  • [44] Quantitative evaluation of coronary stenosis by coronary magnetic resonance angiography
    Watanuki, A
    Yoshino, H
    Udagawa, H
    Yokoyama, K
    Nitatori, T
    Hachiya, J
    Ishikawa, K
    HEART AND VESSELS, 2000, 15 (04) : 159 - 166
  • [45] Quantitative evaluation of coronary stenosis by coronary magnetic resonance angiography
    Atsushi Watanuki
    Hideaki Yoshino
    Hiroshi Udagawa
    Kenichi Yokoyama
    Toshiaki Nitatori
    Junichi Hachiya
    K. Ishikawa
    Heart and Vessels, 2000, 15 : 159 - 166
  • [46] Magnetic Resonance of Coronary Arteries Assessment of Luminal Narrowing and Blood Flow in the Coronary Arteries
    Ishida, Masaki
    Sakuma, Hajime
    JOURNAL OF THORACIC IMAGING, 2014, 29 (03) : 155 - 162
  • [47] MAGNETIC-RESONANCE ANGIOGRAPHY OF THE AORTA, ILIAC, AND FEMORAL ARTERIES
    CARPENTER, JP
    OWEN, RS
    HOLLAND, GA
    BAUM, RA
    BARKER, CF
    PERLOFF, LJ
    GOLDEN, MA
    COPE, C
    SURGERY, 1994, 116 (01) : 17 - 23
  • [48] Magnetic resonance angiography of the visceral arteries: Techniques and current applications
    Li, KCP
    ENDOSCOPY, 1997, 29 (06) : 496 - 503
  • [49] Magnetic resonance digital subtraction angiography (MRDSA) of the carotid arteries
    Wang, Yi
    Comunale, Joseph
    Zimmerman, Robert
    Prince, Martin R.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (01) : 13 - 18
  • [50] Magnetic resonance angiography of human pulmonary arteries during hypoxia
    Moon, RE
    Robertson, PW
    Stolp, BW
    Dear, GD
    Spritzer, CE
    ANESTHESIOLOGY, 1999, 91 (3A) : U521 - U521